G. Cipriani, V. Di Dio, L. D. di Noia, F. Genduso, D. La Cascia, R. Miceli, R. Rizzo
{"title":"A PV plant simulator for testing MPPT techniques","authors":"G. Cipriani, V. Di Dio, L. D. di Noia, F. Genduso, D. La Cascia, R. Miceli, R. Rizzo","doi":"10.1109/ICCEP.2013.6586921","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586921","url":null,"abstract":"This paper introduces a versatile and reliable photovoltaic systems simulator. It includes the main components of a photovoltaic plant: a PV string and a PWM controlled boost chooper. The key feature of this simulator is the ability to consider different and non-uniform irradiation and temperature conditions (partial shading and partial heating of the strings). All the different I-V and P-V or P-I characteristics can then be determined in such non-uniform irradiation and temperature conditions, with the aim to try different MPPT algorithms. The simulator also allows to verify an enhanced version of the Incremental Conductance algorithm (IncCond) where, in order to reach the real absolute maximum power condition, the reference control current of the boost chopper are periodically reset to a given percentage of the short circuit current at standard conditions. After this perturbation, the steady state power values are registered and compared to establish the final value of reference current that allows the IncCond algorithm to reach a steady state at the real abolute maximum power transfer.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127382363","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Langkowski, S. Volcker, A. Lucken, T. Do Thanh, M. Jordan, D. Schulz
{"title":"Grid impedance identification using SiC-Jfet switch-module","authors":"H. Langkowski, S. Volcker, A. Lucken, T. Do Thanh, M. Jordan, D. Schulz","doi":"10.1109/ICCEP.2013.6587008","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6587008","url":null,"abstract":"The grid impedance identification is important to evaluate the effect on the power quality by renewable energy sources using inverters. It can also be used for improved design of existing grid-side filters and the control parameters for the inverters. One approach to determine the grid impedance is based on the switching of an ohmic load. The resulting transients caused by this switching can be used to calculate the frequency dependent grid impedance. In this paper the development of a switch using SiC-Jfets is presented. With this switch high switching frequencies and adjustable slopes within certain limits can be generated which is important for a precise identification of the grid impedance. Measurements of the first 6 kV prototype and the design for the required gate driver are presented.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127444818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Delfanti, L. Frosio, M. Merlo, G. Monfredini, L. Pandolfi, C. Rosati, D. Rosati
{"title":"Dispersed generation to provide ancillary services: AlpStore project","authors":"M. Delfanti, L. Frosio, M. Merlo, G. Monfredini, L. Pandolfi, C. Rosati, D. Rosati","doi":"10.1109/ICCEP.2013.6586979","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586979","url":null,"abstract":"In the future, electrical systems should be able to integrate all users at the same time and guarantee power quality, stability and safety over time. The integration of renewable energy sources leads to new issues involving the intermittence of this generation typology. A high penetration of intermittent power plants will reduce the capability of the system to overcome critical events (e.g. frequency oscillations and voltage profile perturbation). This work presents new regulation schemes/functions developed in the AlpStore project framework, devoted to managing dispersed generation in order to provide ancillary services to the main grid. The work developed can be split into two main items: reactive injection regulation and frequency control regulation. The first regulation is devoted to increasing the Hosting Capacity of the distribution grid (i.e. it results to be a local control), whereas the latter aims to guarantee the energy balance of the national electric grid (i.e. it could be classified as a grid control).","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"526 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123572128","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Lucken, T. Kut, H. Langkowski, S. Dickmann, D. Schulz
{"title":"Concept analysis of an electrical fuel cell integration in modern aircraft","authors":"A. Lucken, T. Kut, H. Langkowski, S. Dickmann, D. Schulz","doi":"10.1109/ICCEP.2013.6586906","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586906","url":null,"abstract":"The reduction of pollutant emissions and hence the increasing of the eco efficiency of future aircraft is one of the major challenges for the aviation industry. Executing the More Electric Aircraft concept can be one approach to achieve these high targets. One idea in this context is to substitute the traditional Auxiliary Power Unit by a Multifunctional Fuel Cell System. It is necessary to transform the load-dependent fuel cell stack output voltage to the intended electrical onboard grid voltage level. To increase the efficiency and reduce the system weight an optimized electrical integration is presented. Measurement results on a test bench confirm the theoretical concepts.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"19 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126631362","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Ramos-Paja, G. Spagnuolo, G. Petrone, S. Serna, A. Trejos
{"title":"A vectorial MPPT algorithm for distributed photovoltaic applications","authors":"C. Ramos-Paja, G. Spagnuolo, G. Petrone, S. Serna, A. Trejos","doi":"10.1109/ICCEP.2013.6586964","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586964","url":null,"abstract":"In this paper a novel multi variable maximum power point tracking algorithm is introduced. The method is suitable for distributed photovoltaic applications and, in contrast with the concept of using a power optimizer for each module working independently from the others, the architecture used in this paper is based on the adoption of a centralized controller for distributed DC/DC converters. The technique uses a vectorial control of the converters that perturbs the operating points of all the DC/DC converters at one time and observes the power transferred to the DC link. Simulation results confirm that the proposed technique performs better than other multi variable controls presented in recent literature.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122404576","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Single-phase multifunctional grid interface converter without grid sincronization","authors":"J. Bonaldo, Filipe N. Braga, J. Antenor Pomilio","doi":"10.1109/ICCEP.2013.6587006","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6587006","url":null,"abstract":"VSI are largely used as grid interface device for DG sources. Extra features have been added to the interface converters, mainly to deal with power quality issues, configuring its use as a multi-function device. In general, the converter acts as a power interface when the DG source is supplying energy and as a power conditioner when the DG source is inactive. In this paper the VSI converter is able to simultaneously operate both as APF and power interface between the grid and the DG source. Also it is possible to operate solely as APF or as an power interface. No synchronization with the grid voltage is required, contributing to the simplicity of the proposed strategy. A single-phase system is simulated validating the strategy.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122444543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Thounthong, M. Phattanasak, P. Sethakul, J. Martin, S. Pierfederici, B. Davat
{"title":"Nonlinear control of a magnetic coupling converter for a supercapacitor storage device for a DC link stabilization","authors":"P. Thounthong, M. Phattanasak, P. Sethakul, J. Martin, S. Pierfederici, B. Davat","doi":"10.1109/ICCEP.2013.6586954","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586954","url":null,"abstract":"This paper presents a new control strategy for dc-link stabilization that use supercapacitors (SC) as the energy storage unit. A three-port isolated converter based on a dual active bridge topology is presented, and a reduced-order mathematical model of the system is described for power plant control. Using a nonlinear control approach based on the flatness property, we propose a simple solution to dynamic and stabilization problems in the power electronics systems. The controller design parameters are independent of the operating point at which interactions between the dc main substation, loads and energy storage unit are taken into account by the controller. Furthermore, high dynamics in the disturbance rejection are achieved, which is the key contribution described in this paper. To validate the proposed method, a hardware system is modeled using digital estimation with a DS1103 dSPACE controller platform. We analyze a prototype small-scale network that uses a 1 kW six-pulse rectifier as a dc substation and a 250 F, 32 V supercapacitor bank (by Maxwell Technologies Inc.) as an energy storage substation. Finally, the utility of the control algorithm is validated using experimental results measured during load cycles.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129720445","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Efficiency analysis of stand alone Wind/Photovoltaic hybrid plant architectures","authors":"A. Yasin, T. Scimone, S. de Caro","doi":"10.1109/ICCEP.2013.6586948","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586948","url":null,"abstract":"A procedure to compare the performance of Wind/Photovoltaic hybrid plants owning the same PV cell array and wind turbine, but different internal configurations is presented in this paper. The selection of the optimal internal configuration for a hybrid generation plant from renewable energies is a complex task and no widely accepted design tools are today available to compare the features of different possible architectures for a given combination of solar irradiation, wind speed and load profiles. To do this a procedure is proposed based on the evaluation of four performance indexes, namely: the global efficiency, the efficiency in transferring energy from RES to BSS, the efficiency in transferring energy from BSS to load and the fraction of useful renewable energy. The paper is mainly focused on low power hybrid Wind/Photovoltaic plants for distributed generation, however, the proposed procedure may also be adapted to high power systems.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128278187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Tagliabue, M. Maistrello, U. Puppini, P. Capodaglio, F. Simonetto, M. Fattor
{"title":"Monitoring of GCHP pilot systems in Valle D'Aosta region: Assessment of performance","authors":"L. Tagliabue, M. Maistrello, U. Puppini, P. Capodaglio, F. Simonetto, M. Fattor","doi":"10.1109/ICCEP.2013.6586953","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586953","url":null,"abstract":"Here are summarized the results of an extended monitoring campaign on three pilot sites in Valle d'Aosta region, located in the northwestern alps, to evaluate energy performance referred to heat extracted and temperature at different depths and with different systems. Experimentation results led to prepare a guide lines aimed for designing properly geothermal plants in a mountainous region, thus focusing on probes spacing, minimum depth of boreholes related to altitude, occurrence/absence of groundwater, morphological factors, practical sizing and indication about operation modes as a function of the hydrogeological conditions.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123828119","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study of doubly fed induction generator for wind power application","authors":"P. Stumpf, I. Nagy","doi":"10.1109/ICCEP.2013.6587016","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6587016","url":null,"abstract":"The paper is concerned with the control of doubly fed induction generator applied in wind power technology. Assuming stator flux oriented vector control, the torque and power relations are derived. Using the relations, the slip versus torque and slip versus stator reactive power characteristics are drafted in subsynchronous and in supersynchronous state for investigating the control possibilities of the generator side converter supplying the rotor circuit. The effects of the d and q component of the converter output voltage for the torque, power and speed are studies in qualitative and quantitative way. The active and reactive power flows in stator and rotor side are shown.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125414443","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}