Cory M Alwardt, Patrick A DeValeria, Ayan Sen, Christopher A Thunberg, Puneet Bhalla, Stephanie Blakeman, Jonathan D'Cunha, Samine Ravanbakhsh
{"title":"First Use of a Novel Extracorporeal Life Support System: Successful Application in Tracheoesophageal Fistula Repair.","authors":"Cory M Alwardt, Patrick A DeValeria, Ayan Sen, Christopher A Thunberg, Puneet Bhalla, Stephanie Blakeman, Jonathan D'Cunha, Samine Ravanbakhsh","doi":"10.1182/ject-73-78","DOIUrl":"https://doi.org/10.1182/ject-73-78","url":null,"abstract":"<p><p>Extracorporeal life support, commonly referred to as extracorporeal membrane oxygenation (ECMO), is indicated when conventional medical and surgical measures fail to support a patient during cardiac or respiratory failure. Increased use of ECMO in recent years has led to innovation that has improved safety in appropriate candidates. This has resulted in the application of novel approaches to complex surgical problems. Herein, we describe a simple, novel, and new-to-market ECMO circuit used for successful perioperative veno-venous ECMO support of a patient undergoing complex repair of a tracheoesophageal fistula. We believe that this circuit and its use for intra-and post-operative extracorporeal support provides a framework for safe and simple ECMO support in the future, including perioperative support for patients undergoing complicated and challenging thoracic procedures.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"73-78"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639688/pdf/ject-73-78.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465167","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Junaid H Khan, Marilyn S Barkin, Jeffrey Stanton, Asim Khan, Russell D Stanten
{"title":"Blood and Blood Product Conservation: Results of Strategies to Improve Clinical Outcomes in Open Heart Surgery Patients at a Tertiary Hospital Are Maintained 4 Years after Initiation.","authors":"Junaid H Khan, Marilyn S Barkin, Jeffrey Stanton, Asim Khan, Russell D Stanten","doi":"10.1182/ject-35-41","DOIUrl":"https://doi.org/10.1182/ject-35-41","url":null,"abstract":"<p><p>Blood product usage is an important outcome for patients undergoing cardiac surgery. In 2015, our center made a concerted effort with multiple departments to focus on reducing transfusion rates in surgical patients requiring cardiopulmonary bypass (CPB). Specific changes included an upgrade of the oxygenator in mid-2015 and, in early 2016, implementation of a hemostasis management system (HMS) that used heparin dose-response titration assays for heparin and protamine management. A retrospective chart review demonstrated significant decreases in the quarterly average of patients receiving packed red blood cells (PRBCs) from a baseline of 26.7% to 22.7% following the oxygenator upgrade (<i>p</i> = .021) and from 22.7% to 8.8% following implementation of the HMS (<i>p</i> = .0017). Platelet usage decreased from an average of 50.5% during the baseline and oxygenator upgrade periods to 22.2% following implementation of the HMS (<i>p</i> < .0001). Usage of fresh frozen plasma (FFP) decreased from an average of 28.2% of cases during the baseline and oxygenator upgrade periods to 10.4% during 2016, and cryoprecipitate usage decreased from 38.5% to 15.4%. Heparin usage averaged 56,903 units before implementation of the HMS, decreasing to an average of 43,796 units following HMS implementation (<i>p</i> < .0001). During the same time periods, protamine usage averaged 340.3 mg and 183.2 mg, respectively. Because improvements achieved during quality initiatives may revert back to their pre-intervention state once the assessment period is over, we performed a second retrospective analysis to determine whether the improvements achieved were maintained during the 48 months following the initial study. During 2017-2020, quarterly average usage of blood products was as follows: PRBCs, 11.9%; platelets, 14.7%; FFP, 6.2%; and cryoprecipitate, 11.5%. Quarterly, average use of heparin and protamine were 31,556 ± 2,757 units and 189 ± 113 mg, respectively. These findings indicate that the improvements achieved were not limited to the duration of the initial quality initiative.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"35-41"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639683/pdf/ject-35-41.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40475972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Early Initiation of Venovenous Extracorporeal Membrane Oxygenation for Critically Ill COVID-19 Patients.","authors":"Takeshi Goto, Shinya Yaguchi, Junko Ogasawara, Naotaka Kato, Jin Irie, Hiroaki Ichikawa, Yuki Nishiya, Yoshiya Ishizawa, Osamu Nomura, Hiroyuki Hanada","doi":"10.1182/ject-79-82","DOIUrl":"https://doi.org/10.1182/ject-79-82","url":null,"abstract":"<p><p>The optimal timing for initiating extracorporeal membrane oxygenation (ECMO) after starting mechanical ventilation has yet to be clarified. We report herein the cases of two patients with coronavirus disease 2019 (COVID-19) acute respiratory distress syndrome (ARDS) who were successfully managed with an early ECMO induction strategy. Case 1 involved a 64-year-old man admitted in respiratory distress with polymerase chain reaction-confirmed COVID-19. On day 5 at hospital, he was intubated, but oxygenation remained unimproved despite mechanical ventilation treatment with high positive end-expiratory pressure (PEEP) (PaO<sub>2</sub>/FiO<sub>2</sub> [P/F] ratio, 127; Respiratory ECMO Survival Prediction [RESP] score, 4). ECMO was initiated 4 hours after intubation, and stopped on day 16 at hospital. The patient was discharged from hospital on day 36. Case 2 involved a 49-year-old man who had been admitted 8 days prior. He was intubated on hospital on day 2. High PEEP mechanical ventilation did not improve oxygenation (P/F ratio, 93; RESP score, 7). ECMO was stopped on hospital on day 7 and he was discharged from hospital on day 21. The strategy of early initiation of ECMO in these two cases may have minimized the risk of ventilation-related lung injury and contributed to the achievement of favorable outcomes.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"79-82"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639695/pdf/ject-79-82.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465164","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sirisha Emani, Vishnu S Emani, Fatoumata B Diallo, Puja Dutta, Gregory S Matte, Meena Nathan, Juan C Ibla, Sitaram M Emani
{"title":"Comparison of Thromboelastography Devices TEG<sup>®</sup>6S Point of Care Device vs. TEG<sup>®</sup>5000 in Pediatric Patients Undergoing Cardiac Surgery.","authors":"Sirisha Emani, Vishnu S Emani, Fatoumata B Diallo, Puja Dutta, Gregory S Matte, Meena Nathan, Juan C Ibla, Sitaram M Emani","doi":"10.1182/ject-42-49","DOIUrl":"https://doi.org/10.1182/ject-42-49","url":null,"abstract":"<p><p>Thromboelastography (TEG) can predict bleeding in pediatric patients undergoing cardiac surgery. We hypothesized that results obtained from TEG<sup>®</sup>5000 correlate with the new point-of-care TEG<sup>®</sup>6S system and that TEG<sup>®</sup>6S rewarming maximum amplitude (MA) is associated with surrogate endpoints for perioperative bleeding in pediatric patients who underwent complex cardiac surgery. We describe a retrospective study of pediatric (≤18 years) patients who underwent complex cardiac surgery on cardiopulmonary bypass. Citrate whole-blood samples were used to compared TEG<sup>®</sup>5000 vs.TEG<sup>®</sup>6S and TEG<sup>®</sup>6S-FLEV (with fibrinogen measurement) vs. Clauss-fibrinogen methods. TEG<sup>®</sup>6S parameters obtained during rewarming were compared to the surrogate endpoints for perioperative bleeding using linear regression analysis. Among 100 patients, 225 TEG<sup>®</sup>5000 vs.TEG<sup>®</sup>6S comparisons and 54 TEG<sup>®</sup>6S-FLEV were analyzed. Good correlation was observed for all parameters comparing TEG<sup>®</sup>5000 to TEG<sup>®</sup>6S and TEG<sup>®</sup>6S-FLEV to the Clauss-fibrinogen method (Pearson r ≥ .7). Similar to rewarming TEG<sup>®</sup>5000 MA, rewarming TEG<sup>®</sup>6S MA was the only parameter independently associated with risk for perioperative bleeding (median [interquartile range {IQR}] in bleeding vs. nonbleeding patients: 35 [29, 48] vs. 37 [32, 55]; <i>p</i> = .02). A platelet transfusion calculator was developed based on TEG<sup>®</sup>6S results by determining the relationship between platelet transfusion volume (mL/kg) and percent change in MA using linear regression analysis. TEG<sup>®</sup>6S is a good alternative point-of-care method to analyze a patient's coagulation profile and it is comparable to TEG<sup>®</sup>5000 in pediatric patients undergoing cardiac surgery on cardiopulmonary bypass. Lower TEG<sup>®</sup>6S MA during rewarming is associated with increased risk for perioperative bleeding. TEG analysis during rewarming may be useful in customizing platelet transfusion therapy by reducing the risk of bleeding while minimizing excessive blood product transfusions.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"42-49"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639686/pdf/ject-42-49.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465163","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Friend or Foe? Venoarterial ECMO via Carotid Artery \"Jump Graft\": A Case Series.","authors":"Hannah K Bauer, Matthew P Malone","doi":"10.1182/ject-67-72","DOIUrl":"https://doi.org/10.1182/ject-67-72","url":null,"abstract":"<p><p>Extracorporeal life support is used in adult and pediatric patients for refractory cardiac and respiratory failure. The great arteries and veins of the neck and groin are often used for cannulation to extracorporeal membrane oxygenation (ECMO). Newer cannulation techniques use the subclavian or axillary arteries, in addition to synthetic grafts anastomosed in end-to-side fashion, from which the cannula is positioned. These newer techniques can prevent need for ligation and sacrifice of important major vessels that is often undertaken in \"traditional\" direct surgical cannulation strategies. To our knowledge this graft technique has not been performed in pediatric ECMO patients. We describe a case series of nine patients from 2012 to 2017 supported with venoarterial (V-A) ECMO utilizing a synthetic Gore-Tex<sup>®</sup> \"jump graft\" sewn in an end-to-side fashion to the right carotid artery, for the arterial cannula insertion. Each patient's hospital course was reviewed with particular consideration given to disease process, site of cannulation, neurologic examination abnormalities noted during ECMO, computed tomography (CT) or magnetic resonance imaging (MRI) evidence of intracranial hemorrhage, and outcomes. Eight of nine patients were successfully cannulated utilizing this technique without neurologic complication. One suffered catastrophic intracerebral hemorrhage. This series is limited by small sample size and single center experience. Further work is needed to determine the advantages and disadvantages of utilizing a synthetic graft in pediatric V-A ECMO.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"67-72"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639696/pdf/ject-67-72.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465166","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Apnea Test on Extracorporeal Membrane Oxygenation: Step Forward with Carbon Dioxide.","authors":"Ozlem Saritas Nakip, Selman Kesici, Kivanc Terzi, Benan Bayrakci","doi":"10.1182/ject-83-87","DOIUrl":"https://doi.org/10.1182/ject-83-87","url":null,"abstract":"<p><p>Apnea test must be performed to confirm brain death in patients meet clinical criteria. But the increment of carbon dioxide is generally not achievable because of the diminished production of carbon dioxide and additional sweep in extra corporeal membrane oxygenation (ECMO). We report three children with congenital heart disease treated with ECMO and had brain death during follow-up. All met clinical criteria but apnea test cannot be achieved in classical way because of prolonged duration and hemodynamic compromise. Therefore, we used external carbon dioxide to achieve desired levels of oxygen and carbon dioxide safely. Because of the lack of protocols for pediatric patients on ECMO, apnea test with exogenous carbon dioxide may be a reliable and rapid test in such patients. Especially cardiac patients, in whom classical apnea test can cause rapid deterioration, exogenous carbon dioxide may serve as an alternative.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"83-87"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639689/pdf/ject-83-87.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40476417","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Diversity and Inclusion to Reduce Disparities.","authors":"Raymond K Wong","doi":"10.1182/ject-3-4","DOIUrl":"10.1182/ject-3-4","url":null,"abstract":"","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"3-4"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639684/pdf/ject-3-4.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465168","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Linda B Mongero, Tami M Rosenthal, Ashley B Walczak
{"title":"A Survey of Women in the Perfusion Workforce: 2021.","authors":"Linda B Mongero, Tami M Rosenthal, Ashley B Walczak","doi":"10.1182/ject-29-34","DOIUrl":"https://doi.org/10.1182/ject-29-34","url":null,"abstract":"<p><p>A diverse and equitable working environment is desirable. In 2011, a survey was distributed to all female perfusionists in the United States. This survey suggested that the female perfusionists share the same difficulties as women in the labor force. The role of women in society in general is clearly changing. Female perfusionists have been part of that evolution. Promoting equality and respecting diversity are central to life today. A follow-up survey was distributed to evaluate the status and the change in gender stereotypes in the field of perfusion over the past 10 years. Women make up nearly half of the U.S. labor force and 35.7% of the present perfusion workforce in North America (1,077 certified women). Women make 82 cents for every dollar that men earn and this disparity widens for women with more education. The purpose of this survey was to poll women in perfusion to evaluate concerns and opinions in their careers and to compare to the 2011 survey results. In December 2021, a 39-question survey (surveymonkey.com, San Mateo, CA) was made available to all female perfusionists in North American via social media websites (Facebook.com, Perfusion.com, LinkedIn.com, Perflist, Perfmail, and FPP Listserv). There were 384 responses to the 2021 survey compared to the 538 responses in 2011. About 32.1% of the survey participants have been used in perfusion for more than 20 years; 37.6% have earned a master's degree compared to 2011, where 18.3% had master's level education; 72.5% are the financial providers for their family with 44.2% earning $101-150,000.00 and 40.3% greater than $200,000.00, which is a significant change from 2011; 61.5% consider themselves under moderate stress compared to 63.0% in 2011; 94.3% take call on a regular basis; and 74.1% feel they miss essential family functions because of their schedules. Similarly, 62.8% felt discriminated against because of gender compared to 50.9% in 2011. This survey suggests that the female perfusionists have shown to be assertive (72% are the primary financial supporter of their families) and competent in the field of cardiovascular perfusion (nearly 40% have masters degrees). Further analysis is needed to discern whether female perfusionists are treated with comparable respect as their male colleagues when 50.0% report some discrimination or harassment in their workplace.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"29-34"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639687/pdf/ject-29-34.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Aashray K Gupta, Lachlan D Kerr, Brandon Stretton, Joshua G Kovoor, Christopher D Ovenden, Joseph N Hewitt, Justin C Y Chan
{"title":"Trends in the Extracorporeal Membrane Oxygenation Literature: A Bibliometric Analysis in the COVID-19 Era.","authors":"Aashray K Gupta, Lachlan D Kerr, Brandon Stretton, Joshua G Kovoor, Christopher D Ovenden, Joseph N Hewitt, Justin C Y Chan","doi":"10.1182/ject-19-28","DOIUrl":"https://doi.org/10.1182/ject-19-28","url":null,"abstract":"<p><p>Extracorporeal Membrane Oxygenation (ECMO) was first used in the 1970s. Its use is increasingly common in critical care and perioperative settings and has gained newfound prominence during COVID-19. To guide future research, we conducted a bibliometric analysis of ECMO literature. Thomson Reuters Web of Science was searched to March 7, 2021. Articles were ranked by total number of citations. Data was extracted from the 100 most cited papers relevant to ECMO for study design, topic, author, year, and institution. Journal impact factor for 2019 and Eigenfactor scores were also recorded. Our search retrieved a total of 18,802 articles. Median number of citations for the top 100 articles was 220 (range 157-1,819). These were published in 34 journals, with first authors originating from 15 countries. The <i>Annals of Thoracic Surgery</i> had the highest number of articles (n = 9) while <i>Lancet</i> publications had the most citations (n = 3,191). Use of ECMO was most commonly observed in cardiogenic shock or acute respiratory distress syndrome. United States had the greatest article output (n = 49). With 10 publications, 2013 was the most prolific year. Using linear regression, when controlled for time since publication, there was no statistically significant relationship between 2019 journal impact factor and number of article citations (<i>p</i> = .09). Top articles in the ECMO literature are of considerable impact and quality. As the United States produced the bulk of the prominent evidence base, and most data were regarding respiratory issues, outsized advances in ECMO may be possible within the United States during the COVID-19 era.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"19-28"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639694/pdf/ject-19-28.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40475974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Pulsatile Perfusion during Cardiopulmonary Bypass: A Literature Review.","authors":"Aileen Tan, Caroline Newey, Florian Falter","doi":"10.1182/ject-50-60","DOIUrl":"https://doi.org/10.1182/ject-50-60","url":null,"abstract":"<p><p>The use of cardiopulmonary bypass (CPB) in cardiac surgery has often been associated with postoperative organ dysfunction. Roller and centrifugal pumps produce non-pulsatile flow (NPF) by default, and this still is the most widely used mode of perfusion. The development of pulsatile pumps has allowed comparisons to be made with NPF. Pulsatile flow (PF) mimics the arterial pulse generated by the heart and is thought to be more physiological by some. This review aims to examine the proposed mechanisms behind the potential physiological benefits of PF during CPB and to summarize the current clinical evidence. MEDLINE and EMBASE were used to identify articles published over a 25 year period from 1995 to 2020. A literature review was conducted to determine the effects of PF on organ functions. A total of 44 articles were considered. Most of the articles published on PF were randomized controlled trials (RCTs). However, there was a wide variation in study methodology, method of pulse generation and how pulsatility was measured. Most of the evidence in favor of PF showed a marginal improvement on renal and pulmonary outcomes. In these studies, pulsatility was generated by an intra-aortic balloon pump. In conclusion, there is a lack of good quality RCTs that can inform on the short- and long-term clinical outcomes of PF. Further research is required in order to draw a conclusion with regards to the benefits of PF on organ function.</p>","PeriodicalId":39644,"journal":{"name":"Journal of Extra-Corporeal Technology","volume":"54 1","pages":"50-60"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639690/pdf/ject-50-60.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40465169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}