Periodica polytechnica Electrical engineering and computer science最新文献

筛选
英文 中文
A High Robust Optimal Nonlinear Control with MPPT Speed for Wind Energy Conversion System (WECS) Based on Doubly Fed Induction Generator (DFIG) 基于双馈感应发电机(DFIG)的风能转换系统(WECS)高鲁棒非线性最优控制
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-10-05 DOI: 10.3311/ppee.22595
Toufik Mebkhouta, Amar Golea, Rabia Boumaraf, Toufik Mohamed Benchouia, Djaloul Karboua
{"title":"A High Robust Optimal Nonlinear Control with MPPT Speed for Wind Energy Conversion System (WECS) Based on Doubly Fed Induction Generator (DFIG)","authors":"Toufik Mebkhouta, Amar Golea, Rabia Boumaraf, Toufik Mohamed Benchouia, Djaloul Karboua","doi":"10.3311/ppee.22595","DOIUrl":"https://doi.org/10.3311/ppee.22595","url":null,"abstract":"As part of efforts to improve wind energy production using a doubly fed induction generator (DFIG), this paper presents modeling with power maximization through control of speed (MPPT) and control of stator active and reactive power for doubly fed induction generator. The quality of the generated energy and the performance of wind energy conversion systems (WECS) based on DFIG are affected by uncertainties and external disturbances. Therefore, the system requires high-performance control under the nonlinearity influence and the applied external disturbances. This work provides a new contribution and approach that combines nonlinear control (Backstepping) and optimal control (LQR). Backstepping control has been applied to give a good performance using nonlinear strategy and stability condition, but its main drawback is that it is relatively robust for sudden changes in wind speed or any external disturbances as well as it is sensitive against the uncertainties, which may lead to a chattering and an instability as well as overshoot or undershoot. To overcome the problems mentioned above the optimal control (LQR) has been applied to address this drawback in nonlinear control. Furthermore, it, the hybrid approach of Backstepping and LQR control resulting a robust control under the hardest scenarios during the wind system operating as well as provides a good performance in terms of chattering, stability and other performance characteristics which help to produce a high-quality energy. Overall, integrating LQR control with Backstepping can lead to a more powerful, flexible, and efficient control system with improved performance and reduced computational complexity.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134976157","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Extraction of the Global Maximum Power for PV System under PSC Using an Improved PSO Technique 基于改进粒子群算法的PSC下PV系统全局最大功率提取
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-09-28 DOI: 10.3311/ppee.22254
Claude Bertin Nzoundja Fapi, Hyacinthe Tchakounté, Martial Ndje, Patrice Wira, Martin Kamta
{"title":"Extraction of the Global Maximum Power for PV System under PSC Using an Improved PSO Technique","authors":"Claude Bertin Nzoundja Fapi, Hyacinthe Tchakounté, Martial Ndje, Patrice Wira, Martin Kamta","doi":"10.3311/ppee.22254","DOIUrl":"https://doi.org/10.3311/ppee.22254","url":null,"abstract":"To get the most power out of photovoltaic (PV) panels, PV systems must utilize a maximum power point tracking (MPPT) controller. In partial shading conditions (PSC), the power-voltage (P-V) characteristic of the PV network may show a single global maximum power point (GMPP) and two or more local maximum power points (LMPP). This indicates that the PV cells and panels do not get uniform illumination. As they converge on the maximum power point (MPP) that makes contact first, which is often one of the LMPPs in this scenario, common MPPT approaches like incremental conductance (InC) and perturb and observe (P&O) are unable to distinguish between a GMPP and LMPPs. In this paper, the extraction of the GMPP of the PV system under PSC based on a suggested particle swarm optimization (PSO) approaches is presented. The particularity of the suggested approach is that it takes into account the calculation of the position of each particle as a function of the duty cycle and the global maximum power. Results on the performance of the suggested PSO method show an advantage over the conventional PSO and the commonly used traditional P&O method. The suggested PSO technique offer better performance in terms of global power extracted, ripple rate of the power and efficiency.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135387516","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Resonant Waveguide Grating Biosensors Based on Label-free Optical Principle 基于无标签光学原理的谐振波导光栅生物传感器
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-09-22 DOI: 10.3311/ppee.22878
Igor Sallai
{"title":"Resonant Waveguide Grating Biosensors Based on Label-free Optical Principle","authors":"Igor Sallai","doi":"10.3311/ppee.22878","DOIUrl":"https://doi.org/10.3311/ppee.22878","url":null,"abstract":"Label-free optical biosensors are powerful tools for the real-time monitoring of both molecular and cellular-scale interactions. Resonant waveguide grating biosensors are based on the detection of refractive index changes induced by molecular interactions and/or cell mass redistributions. The Epic BenchTop and Epic Cardio are two biosensors with high sensitivity and throughput that offer excellent potential for life science research. Both instruments are suitable for cell-based and biochemical assays. In this paper, I describe the principles of operation and performance of the Epic BenchTop and Epic Cardio label-free waveguide grating biosensors and discuss their applications in various research areas.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136060096","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Data Augmented of Mechanical Fault Sound Signal based on Generative Adversarial Networks 基于生成对抗网络的机械故障声信号数据扩充
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-09-20 DOI: 10.3311/ppee.22427
Yining Yang, Xiang Su, Nan Li
{"title":"Data Augmented of Mechanical Fault Sound Signal based on Generative Adversarial Networks","authors":"Yining Yang, Xiang Su, Nan Li","doi":"10.3311/ppee.22427","DOIUrl":"https://doi.org/10.3311/ppee.22427","url":null,"abstract":"In this paper, a global average pooling convolutional neural network based on CNN is proposed for mechanical fault sound detection, which called as GCMD. To solve the data scarcity of mechanical fault sound data, a spectrum frame selection augmented method based on log Mel spectrum feature is proposed to augment the original data, that aim is to train GCMD and generate counter networks. In order to solve the unbalance problem of data set and further improve the generalization ability of GCMD, an augmented neural network model based on CapsuleGAN was proposed, which called MFS-CapsuleGAN. The model was evaluated on the augmented data set by training GCMD neural network. Compared with the original data set, the accurate recognition rate of the model was improved by 23.7%. The performance of this method is improved significantly, which proves the feasibility and effectiveness of MFS-CapsuleGAN data augmented. In addition, the data set with background noise was used to test the generalization ability of GCMD network. The fluctuation range was within 0.117, indicating the good robustness of GCMD network.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136313786","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis and Design of Voltage-controller Based on Single-state Feedback Active Damping for Grid-forming Converters 基于单态反馈主动阻尼的成网变流器电压控制器分析与设计
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-08-28 DOI: 10.3311/ppee.21420
F. Abdoune, I. Abadlia, A. Beddar, L. Hassaine, Mohamed Reda Bengourina
{"title":"Analysis and Design of Voltage-controller Based on Single-state Feedback Active Damping for Grid-forming Converters","authors":"F. Abdoune, I. Abadlia, A. Beddar, L. Hassaine, Mohamed Reda Bengourina","doi":"10.3311/ppee.21420","DOIUrl":"https://doi.org/10.3311/ppee.21420","url":null,"abstract":"This paper investigates the analysis and design of digital single-loop voltage-controller for grid-forming voltage source converters with LC-filters. Inspired by the structure diagram of the passive damping method, the virtual resistance concept based on only capacitor voltage feedback is used to realize active damping without the need of any current sensor, reducing thus the system costs. It is revealed from the controller closed-loop analysis that the insertion of an integrator in series with a proportional and resonant controller can significantly improve stability margin and dynamic performance of the system, then only the proportional controller need to be determined for system stability and the resonant controller is merely used for zero steady-state tracking error, which facilitates the controller parameter tuning. A systematic design based on the root contours in the discrete z-domain is proposed to optimize the parameters of the controller. The largest distance between the poles of the closed-loop system and the unit circle is achieved, which indicates the fastest dynamic performance under desired stability margins. Meanwhile, a simple differentiator constructed by backward-Euler plus lead-compensator is used to replace the noise-sensitive derivative term. In order to evaluate the proposed control approach performance, the system is tested in laboratory setup under different load conditions. The obtained results verify the effectiveness of the proposed design method and validate the analysis.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47936217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigating the Performance of Non-standard Overcurrent Relay with Integration of Photovoltaic Distributed Generation in Power Distribution System 光伏分布式发电一体化非标准过流继电器在配电系统中的性能研究
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-08-25 DOI: 10.3311/ppee.21780
M. Zellagui, N. Belbachir, Mohammed Amroune, C. El‐Bayeh
{"title":"Investigating the Performance of Non-standard Overcurrent Relay with Integration of Photovoltaic Distributed Generation in Power Distribution System","authors":"M. Zellagui, N. Belbachir, Mohammed Amroune, C. El‐Bayeh","doi":"10.3311/ppee.21780","DOIUrl":"https://doi.org/10.3311/ppee.21780","url":null,"abstract":"The electricity demand is increasing daily, so the generation power should be raised to fulfil that demand. Renewable distributed generation-based photovoltaic sources are one of the best solutions to satisfy the Power Distribution System (PDS) as long as the fossil resources are on the verge of extinction. At the same time, connecting the Photovoltaic Distributed Generation (PVDG) to the PDS may cause issues with the system's technical parameters, such as a protection system based on overcurrent relays, unless they are optimally allocated. In this context, this paper will be devoted to optimally allocating multiple PVDG units in the PDS using the Slime Mould Algorithm (SMA), meanwhile studying the impact of that optimal integration on the overcurrent protection system that will be represented and based on various chosen non-standard overcurrent relays (NS-OCRs) which many researchers develop, and trying to figure out and pick up the best type that provides improvement to the protection system including the minor impact on the coordination time interval. To achieve the maximum and best of the requested results, a multi-objective function was proposed to be minimized based on the sum of total active power loss, total voltage deviation, and total operating time of the relays.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41735601","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Hybrid Spatial Adaptive Modulation and Frequency Stochastic Approach for MU-MIMO-OFDM Systems in the Context of Underlay Cognitive Radios 底层认知无线电环境下MU-MIMO-OFDM系统的混合空间自适应调制和频率随机方法
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-08-25 DOI: 10.3311/ppee.21022
Rym Labdaoui, K. Ghanem, F. Y. Ettoumi
{"title":"A Hybrid Spatial Adaptive Modulation and Frequency Stochastic Approach for MU-MIMO-OFDM Systems in the Context of Underlay Cognitive Radios","authors":"Rym Labdaoui, K. Ghanem, F. Y. Ettoumi","doi":"10.3311/ppee.21022","DOIUrl":"https://doi.org/10.3311/ppee.21022","url":null,"abstract":"In this paper, low complexity rate and power optimization schemes operating in the spatial and frequency domains are proposed in a cognitive radio (CR) setting involving multi-user multiple-input-multiple-output-orthogonal frequency division multiplexing (MU-MIMO-OFDM). Under the assumption of a perfect secondary channel state information (CSI) at the receiver, the presented architectures encompass two main stages. In the first one, spatial power waterfilling-like method is performed per each MIMO subchannel pertaining to each subcarrier of each secondary user (SU). The resulting allocated power per each eigen-channel is considered as the power budget in the second stage. In this latter, stochastic algorithm-based approach wherein the transmit parameters per each subcarrier of each SU are adapted such that to maximize the achievable sum-rate capacity of the SUs. Three different schemes are introduced in this work. First, the derivation of the continuous rate MU-MIMO-OFDM-CR version, referred to as C-MU-MIMO-OFDM-CR is presented. Obviously, this proposition is theoretical and is taken as a benchmark for the two remaining counterparts. The second proposition we called discrete-rate MU-MIMO-OFDM-CR, and briefly designated as D-MU-MIMO-OFDM-CR which is to round the provided allocated rate. Finally, the third modified solution, denoted as P-D-MU-MIMO-OFDM-CR proceeds in a similar way as the D-MU-MIMO-OFDM-CR alternative, but superimposes the non/over-used amount of power to the power budget in next iteration. The simulation results show that, compared to the discrete rate D-MU-MIMO-OFDM-CR solution, the P-D-MU-MIMO-OFDM-CR approach exhibits an approximate power gain of 1 dB when the SNR level is low, and of 5 dB at high SNR range.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42692691","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Collection Efficiency of ESP in a Numerical Model Using One and Multiple Independent Power Supplies 一个和多个独立电源的ESP收集效率数值模型的比较
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-08-22 DOI: 10.3311/ppee.22492
László Székely, I. Kiss
{"title":"Comparison of Collection Efficiency of ESP in a Numerical Model Using One and Multiple Independent Power Supplies","authors":"László Székely, I. Kiss","doi":"10.3311/ppee.22492","DOIUrl":"https://doi.org/10.3311/ppee.22492","url":null,"abstract":"This work modeling the collection efficiency of an ESP numerical model based on industrial plant development. Under high dust loads, one power supply controlled the voltages on the two separation zones. The separation efficiency is different depending on the diameter of the dust particles, so the two zones receive dust particles with various distributions, and the electrical characteristics are not the same. In this article, we show the change in the efficiency of separation when the two zones are controlled at different voltages by power supplies.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41335312","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Solar PV Model Parameter Estimation Based on the Enhanced Self-Organization Maps 基于增强自组织映射的太阳能光伏模型参数估计
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-08-07 DOI: 10.3311/ppee.22209
Mouncef El marghichi
{"title":"A Solar PV Model Parameter Estimation Based on the Enhanced Self-Organization Maps","authors":"Mouncef El marghichi","doi":"10.3311/ppee.22209","DOIUrl":"https://doi.org/10.3311/ppee.22209","url":null,"abstract":"Solar photovoltaic (PV) is a commonly utilized renewable energy source, with PV cells often being modeled as electric circuits. The identification of suitable circuit model parameters for PV cells is vital for performance evaluation, efficiency calculations, and the implementation of maximum power point tracking in solar PV systems. However, modeling the solar PV system is a nonlinear problem that requires an efficient algorithm. In this paper, we employ the enhanced self-organization maps (EASOM) to efficiently reduce the search space for parameter estimation in solar PV models. Our algorithm trains the SOM network on a subset of solutions, identifies the top solution's neural unit, generates a population of potential solutions, and selects the best candidate using a cost function, which represents the best PV model parameters obtained. The performance of EASOM is verified by extracting the parameters of the single diode (SDM) and double diode (DDM) models for the STM6-40/36 PV module. EASOM outperformed state-of-the-art algorithms with the lowest RMSE and MSE values of 8.3 mA and 6.87e-05 and achieved the lowest maximum error values of 27.37 mA and 20.52 mA, as well as low power error of 66.04 mW and 62.8 mW for SDM and DDM models.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42472777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative Study of Robust RSC Control of Doubly Fed Induction Generator Based Wind Turbine under Grid Frequency and Voltage Variations 电网频率和电压变化下基于双馈感应发电机的风力发电机鲁棒RSC控制的比较研究
Periodica polytechnica Electrical engineering and computer science Pub Date : 2023-07-17 DOI: 10.3311/ppee.21333
Hakima Bahlouli, A. Mansouri, M. Bouhamida
{"title":"Comparative Study of Robust RSC Control of Doubly Fed Induction Generator Based Wind Turbine under Grid Frequency and Voltage Variations","authors":"Hakima Bahlouli, A. Mansouri, M. Bouhamida","doi":"10.3311/ppee.21333","DOIUrl":"https://doi.org/10.3311/ppee.21333","url":null,"abstract":"The configuration of a grid-connected doubly fed induction generator (DFIG) for wind energy generation systems consists of direct coupling of the generator stator windings with the grid and partial coupling of the rotor through power converters. This structure makes the system sensitive to the fault grid. Thus, robust control techniques are required to deal with the undesirable transient sequences in the network. In this paper, two robust controllers have integrated to regulate the stator active and reactive power of DFIG based wind turbine. Then, they have been tested and compared to verify their performances when abnormal grid networks have occurred. Firstly, we used high order sliding mode (HOSM) based Super Twisting, which keeps the same conventional sliding mode performances, such as fast dynamic response and redundancy to the extern disturbances, with a simple design and chattering reduction. Secondly, we implement the backstepping control approach which is known for its robustness in transient sequences. A number of simulations have carried out to evaluate the ride-through performance of both control strategies in case of low grid voltage dips and grid frequency variations.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45519355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信