S. Bala, Jiuping Pan, D. Das, O. Apeldoorn, S. Ebner
{"title":"Lowering failure rates and improving serviceability in offshore wind conversion-collection systems","authors":"S. Bala, Jiuping Pan, D. Das, O. Apeldoorn, S. Ebner","doi":"10.1109/PEMWA.2012.6316362","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316362","url":null,"abstract":"Reliability and maintenance are key concerns for offshore wind farms. Electrical systems are responsible for more failures than mechanical or structural systems, but they are also comparatively easier to repair. Nevertheless, it is important to lower the rate of failure and improve the ease of maintenance of electrical systems. This paper presents approaches to achieve these goals at the component level as well as at the system level. ABB's PCS6000 is used as the example to discuss component level issues. This paper also compares five possible conversion-collection system architectures considering their reliability and amenability to maintenance. The failure rates can be lowered and the serviceability can be improved by incorporating these considerations properly at the design stage.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123608913","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"LFAC-transmission systems for remote wind farms using a three-phase, six-pulse cycloconverter","authors":"Yongnam Cho, G. Cokkinides, A. Meliopoulos","doi":"10.1109/PEMWA.2012.6316404","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316404","url":null,"abstract":"This paper presents an alternative transmission system for remote wind farms to main grids using a low-frequency AC (LFAC) technology and a robust-modeling method for analysis of the alternative-transmission systems. The LFAC transmission system uses a lower frequency (20Hz/16.666Hz) than nominal frequency (60Hz/50Hz) of main grids by introducing a three-phase six-pulse cycloconverter. The benefits of the LFAC transmission system are demonstrated as follows: reduced-investment cost compared with HVDC-transmission systems and increased power transfer capability as compared with 60Hz-HVAC transmission systems. In this paper, the economical and technical benefits of LFAC transmission systems are presented, the modeling method using the quadratic-integration method is presented, and the superior properties of the quadratic integration are demonstrated with an example LFAC-transmission system.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129214251","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Popova, Tatu Musikka, R. Juntunen, M. Lohtander, P. Silventoinen, O. Pyrhonen, J. Pyrhonen
{"title":"Modelling of low inductive busbars for medium voltage three-level NPC inverter","authors":"L. Popova, Tatu Musikka, R. Juntunen, M. Lohtander, P. Silventoinen, O. Pyrhonen, J. Pyrhonen","doi":"10.1109/PEMWA.2012.6316369","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316369","url":null,"abstract":"Design of low inductive busbars for medium voltage Neutral Point Clamped (NPC) inverter is studied. In a hard-switched inverter the stray inductance causes various problems, such as over voltages, current unbalance, and possible resonance with DC-link capacitors. These problems lead to improper operation of the inverter and an increased level of electromagnetic interference (EMI). The laminated busbars are known to be a good solution for minimizing the stray inductance. It is important to estimate and minimize the stray inductance of the busbars in an early design stage. FLUX3D is used to compare three physical layouts and analyze the influence of the placement of the main circuit components on the inductance value.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122474989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wind power technologies from the perspective of system operator","authors":"B. Kang, Jae-Do Park","doi":"10.1109/PEMWA.2012.6316364","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316364","url":null,"abstract":"Various wind turbines have been developed and operated in distribution systems and transmission systems. The usage of wind power is now rapidly growing worldwide and some leading countries in wind power technologies have been developing new strategies and enhanced requirements for power system security and electrical power quality. But most of power systems have not prepared for them yet. Given the fact that the renewable energy sources, such as wind power, photovoltaic, fuel cells will be getting more importance for the future energy systems with the benefit of emission trading, most of developing countries and power systems that are not preparing for such movement should make their future plan not only for the power system security, but also for their economic development. In this paper, wind power technologies, which is one of the most promising alternative energy sources, is summarized from the viewpoint of power system operation and control.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127070737","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis and comparison between two wind farms consisting of 500kW midsize turbines and 1.5MW turbines","authors":"S. Pappu, S. Nimmagadda, S. Bayne","doi":"10.1109/PEMWA.2012.6316396","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316396","url":null,"abstract":"This paper compares the characteristics of two wind farms of same power capacity having two different size generators. The research compares the performance of mid-size turbines to large turbines. The systems were modeled in MATLAB-Simulink. With rapid development in wind power generation it's necessary to study the different characteristics of wind farms having different generator configurations. A 9MW wind farm consisting of eighteen Fixed Speed Induction Generators (FSIG) with STATCOM at the terminals of the wind farm is compared to a 9MW wind farm consisting of six Doubly Fed Induction Generators (DFIG) interfaced with Power Electronics on the rotor. The models of FSIG wind power generation system and DFIG wind power generation system connected to the grid are built. An analysis on total power available for transmission, reactive power consumption at different wind speeds (cut in, rated, cut off), power loss due to loss of turbines.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"134 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131777343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wind resource assessment in southeast Finland","authors":"K. Hynynen, E. Baygildina, O. Pyrhonen","doi":"10.1109/PEMWA.2012.6316376","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316376","url":null,"abstract":"Wind power production in Finland is increasing in near future. Most of the existing and planned wind farms are located in the costal and fell areas where the highest wind speeds occur. The purpose of the present paper is to investigate the inland wind conditions and wind power potential in South-Karelia, southeast Finland, based on wind speed measurements in three locations and several heights. The results show that South Karelia has potential for wind power production with high enough hub heights.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"96 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124658668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wind plant reactive power and voltage compliance with grid codes","authors":"R. Kunte, C. Pallem, D. Mueller","doi":"10.1109/PEMWA.2012.6316359","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316359","url":null,"abstract":"One important aspect of wind turbine controls is the ability to control the power factor and/or the plant system voltage, in order to comply with interconnection agreements. There are references readily available that discuss control issues regarding the dynamic performance for wind plants, but very little information has been published regarding the overall wind plant operation towards meeting the interconnection requirements for reactive power and voltage control. This paper presents examples of different grid code requirements and how the turbine operation with either voltage or power factor control is used in practice. Some power flow simulation case results are given to illustrate these concepts, and how compliance is achieved at the point of interconnection.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121785361","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wind turbine adaptive controller modeling","authors":"E. Baygildina, K. Hynynen, O. Pyrhonen","doi":"10.1109/PEMWA.2012.6316372","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316372","url":null,"abstract":"In the time of current trend of increasing energy consumption, the wind-power engineering may compensate considerable part of required electric energy. Rapid wind power engineering development is considered to be one of the important sources of human need satisfaction. Conventional wind turbine control strategies are dedicated to ensure high energy conversion efficiency under varying wind conditions. The challenge in wind power control engineering is to design an adaptive wind turbine control strategy, which provides the dynamic system stability and the effectiveness of energy conversion. Modern vector controlled wind turbine drives allow fast and accurate torque control on a wide speed range. The aim of this paper is to design and implement the control algorithm, which implies the electromagnetic torque control in order to adapt the optimal rotor speed and keep high energy conversion efficiency, taking full advantage of electrical drive performance. Wind turbine operation is considered in the partial-load regime. The stability of the purposed control system is studied using linear control theory concepts. The effectiveness of the wind energy conversion is proved by the simulation results in MATLAB Simulink environment.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123802881","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Combining droop curve concepts with control systems for wind turbine active power control","authors":"A. Buckspan, J. Aho, P. Fleming, Y. Jeong, L. Pao","doi":"10.1109/PEMWA.2012.6316403","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316403","url":null,"abstract":"Wind energy is becoming a larger portion of the global energy portfolio, and wind penetration has increased dramatically in certain regions of the world. This increasing wind penetration has driven the need for wind turbines to provide active power control (APC) services to the local utility grid, as wind turbines do not intrinsically provide frequency regulation services that are common with traditional generators. Large scale wind turbines are typically decoupled from the utility grid via power electronics, which allows the turbines to synthesize APC commands via control of the generator torque and blade pitch commands. Consequently, the APC services provided by a wind turbine can be more flexible than those provided by conventional generators. This paper focuses on the development and implementation of both static and dynamic droop curves to measure grid frequency and output delta power reference signals to a novel power set point tracking control system. The combined droop curve and power tracking controller is simulated and comparisons are made between simulations using various droop curve parameters and stochastic wind conditions. The tradeoffs involved with aggressive response to frequency events are analyzed. At the turbine level, simulations are performed to analyze induced structural loads. At the grid level, simulations test a wind plant's response to a dip in grid frequency.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128000595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparison of individual and combined forecasting of wind power output of two wind farms in Western Australia","authors":"B. Banerjee, D. Jayaweera, S. Islam","doi":"10.1109/PEMWA.2012.6316395","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316395","url":null,"abstract":"Large penetration of wind farms in the electricity grid is expected to be an unknown challenge in the near future. The biggest factor is the intermittency of wind turbine output and the difficulty in forecasting it accurately. A number of studies on wind forecasting have shown that the error of statistical methods increases with forecast horizon. However, combined forecasting of geographically dispersed wind farm output, sees a reduction in error. This paper extends this further by analysis of the confidence interval and uncertainty of forecasts when combined forecasting is used. It is observed that both the forecast error as well as uncertainty is reduced when combined forecasting is used for two wind farms in Western Australia. For a short term forecasting horizon of 6 hours, maximum forecasting error is reduced by 6% while uncertainty is reduced by up to 20%. This is expected to improve if more wind farms are considered.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116505554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}