{"title":"Validation of distribution level measurements for power system monitoring and low frequency oscillation analysis","authors":"A. Allen, Sang-Wook Sohn, W. Grady, S. Santoso","doi":"10.1109/PEMWA.2012.6316392","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316392","url":null,"abstract":"The University of Texas at Austin introduced the Independent Synchrophasor Network in order to monitor events and analyze low frequency oscillations from the electric power grid through PMU measurements taken at customer level voltage (120 V). The purpose of this paper is to present validation of the quality of these distribution level measurements for power system monitoring and analysis. Three different steps are used in the validation process. In the first step, the distribution voltage phase angle measurements are plotted with and compared to the state estimated transmission level voltage phase angle. The second step is the comparison of distribution level PMU measurements to transmission level PMU measurements during a power system transient response. The frequency, voltage magnitude, and voltage phase angle are analyzed during a unit trip event. In the final step, the modal frequency and damping estimates are used to illustrate the accuracy of distribution measurements as representative of the power system's ambient response. Because of the location of the PMUs within the network, it will also be possible to measure the effects of wind power on the rest of the grid.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"42 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126095156","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A variable duty cycle Maximum Power Point Tracking algorithm for Wind Energy Conversion Systems","authors":"George Joseph, J. Foreman, M. McIntyre","doi":"10.1109/PEMWA.2012.6316379","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316379","url":null,"abstract":"A new Maximum Power Point Tracking (MPPT) algorithm employed in Wind Energy Conversion Systems (WECS) is presented. This novel algorithm mitigates the problems of traditional Hill Climb Search (HCS) methods while extracting the maximum power during a change in wind speed. The algorithm also eliminates the oscillations in delivered power once the maximum power point (MPP) is found. To accomplish this, the algorithm employs a variable duty cycle search and terminates the search once the MPP is found. The effectiveness of this proposed algorithm was evaluated using MATLAB-SIMULINK in a WECS with results in the mid-90th percentile.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"17 424 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129859973","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Roshanfekr, T. Thiringer, S. Lundmark, M. Alatalo
{"title":"Selecting IGBT module for a high voltage 5 MW wind turbine PMSG-equipped generating system","authors":"P. Roshanfekr, T. Thiringer, S. Lundmark, M. Alatalo","doi":"10.1109/PEMWA.2012.6316407","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316407","url":null,"abstract":"In this paper, a fairly high voltage generating system for a 5 MW generating system is investigated. The generating system consists of a surface mounted PMSG (Permanent Magnet Synchronous Generator) with a 2-level transistor converter. The focus is on utilizing three available high voltage IGBT-modules, and to investigate the resulting losses when using them to compose a converter, in order to observe the difference as well as the best choice. In addition, the ideal dc-link voltage for a certain module as well as for a certain main average wind speed is studied. It is found that the most suitable module to use from the loss point of view is the 1.7 kV module, the one with the lowest voltage rating. The difference towards using the 6.5 kV module is a loss increase in the converter at rated operation of 62 %. This is in spite of that a converter composed of the 6.5 kV module has less than half of the conduction losses compare to 1.7 kV module. Accordingly, it can be understood that the switching losses increase much stronger than the conduction losses decrease when using a module with higher voltage rating. When looking at the average annual energy efficiency difference, the best annual efficiency is also achieved when the converter is composed with the 1.7 kV modules.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124097930","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design and control of a single-phase D-STATCOM inverter for wind applications","authors":"C. Tareila, P. Sotoodeh, R. Miller","doi":"10.1109/PEMWA.2012.6316358","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316358","url":null,"abstract":"Application of renewable energy systems has become very popular. Since most utilities do not track the end points of their distribution lines carefully, where most of the wind turbines are connected to the grid, increasing the application of renewable energies in utilities can result in problems for the whole system dynamics. This paper presents the design and control of a D-STATCOM inverter for small to mid-sized wind turbines (10kW-20kW) to solve the problem of power factor correction of the grid. The proposed D-STATCOM Inverter can control the VARs on each single feeder line while the output of the renewable energy source, especially wind, is varying. Active power is controlled by shifting the phase angle while reactive power control is achieved by modulation index control. Also, the inverter is able to eliminate a large amount of harmonics using the optimized harmonic stepped waveform (OHSW) technique. The proposed inverter utilizes the hybrid-clamped topology. All simulations were done in MATLAB/Simulink environment.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"95 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114200733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Single grid connection of Doubly-Fed Induction Generator for wind turbines","authors":"Yongsu Han, Wook-Jin Lee, Jung-Ik Ha","doi":"10.1109/PEMWA.2012.6316397","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316397","url":null,"abstract":"This paper proposes a new configuration of wind energy conversion system, called Single External Feeding of Doubly-Fed Induction Generator (SEF-DFIG), and its control scheme. In the proposed configuration, the stator windings are directly connected to the grid, and the rotor windings are fed by an isolated inverter with no power source. Since the power electronics including dc link capacitors can be integrated into the rotor, it is possible to eliminate slip rings and brushes, which are requisites in the conventional DFIG system. The isolation of the rotor circuits requires controlling the dc link voltage by manipulating the rotor power. For this reason, the controllability of the power factor is limited, so it is important to optimize the operating points depending on the generated power and speed. Several considerations on the characteristics of the proposed system; torque, power factor, possible operating area and efficiency for wind turbine applications are analyzed. And where the SEF-DFIG is applied in wind turbine system, the considerations for the performances are also discussed. The experimental results of a 2kW DFIG system are presented to prove the feasibility of the proposed system and method.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121806225","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A novel current control scheme of grid converters for small PMSG wind turbines under grid voltage distortion","authors":"T. Nguyen, Dong-Choon Lee","doi":"10.1109/PEMWA.2012.6316368","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316368","url":null,"abstract":"This paper proposes a robust control scheme for the grid-connected single-phase converter of small permanent-magnet synchronous generator (PMSG) wind turbines under distorted grid voltages. The single-phase grid current is controlled to be sinusoidal by eliminating the high-order harmonic components. For this, the fundamental and high-order harmonic components of the grid voltage and current are extracted by the composite observer without a delay. Then, a phase-lock loop (PLL) scheme is employed for the fundamental component of the grid voltage to detect the phase angle of the grid voltage for the grid current controller. The multi-PR (proportional-resonant) controllers are used to regulate the grid current. In the system, the boost converter controls the DC-link voltage and the grid converter controls the generator output power. The validity of the proposed scheme is verified by the simulation and experimental results.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125169388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new course on control of wind power generation systems using analysis and simulation","authors":"B. Sarlioglu, D. Pan, G. Choi","doi":"10.1109/PEMWA.2012.6316366","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316366","url":null,"abstract":"This paper presents a new graduate-level course that is designed, developed, and taught at the University of Wisconsin-Madison to further advance the education for wind power technologies. The objective of this course is to provide an in-depth coverage of control of electric drives for wind turbines with an emphasis using state-of-the-art modeling and simulation techniques. Various generator types and their associated controlling techniques for wind power generation are reviewed in the course. The course begins with a thorough discussion of the performance requirements for electric power generating equipment controls in wind turbine applications. Analyses and simulations of electric generators combined with their controls are incorporated into the class curriculum to provide students with a thorough understanding of the achievable generating system performance. The course capitalizes on the student's prior knowledge in drives, power electronics, and electric machines to develop highly skilled, advanced degree graduates that can readily become researchers or developers of next-generation wind power generation systems.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123876199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"HVDC Light for large offshore wind farm integration","authors":"D. Das, J. Pan, S. Bala","doi":"10.1109/PEMWA.2012.6316363","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316363","url":null,"abstract":"Integration of large offshore wind farms with the existing grid poses significant techno-economical challenges. As offshore wind farms are moving towards higher power and higher distance from shore, voltage source converter based high voltage direct current (VSC-HVDC) systems have proven technically advantageous and more cost-efficient than conventional high voltage alternating current (HVAC) transmission. The paper discusses the various advantages of connecting offshore wind farms with the onshore grid using HVDC Light - ABB's product name of VSC-HVDC technology. The paper gives an overview of HVDC Light converter and cable technologies and introduces several HVDC Light projects for offshore wind integration.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"590 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123184495","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Increasing wind farm connectivity in a utility distribution system","authors":"R. Varma, R. Seethapathy, O. Ben-Shlomo","doi":"10.1109/PEMWA.2012.6316402","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316402","url":null,"abstract":"The connection of Distributed Generation (DG) to the distribution system can be limited by factors such as steady state voltage rise, temporary over voltage (TOV) during single line to ground (SLG) faults and other limits defined by the utility. The installation of a Static Var Compensator (SVC) on a distribution feeder can increase the allowable DG penetration by addressing the above mentioned limiting factors. This paper examines the benefits of using a SVC with a novel controller modification to improve TOV reduction while substantially increasing the amount of wind based generation connected to a distribution feeder. Studies are performed in EMTDC/PSCAD on a real distribution feeder located in Ontario, Canada with a desired target of connecting 20MW of wind based generation.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121323142","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Villena-Lapaz, A. Vigueras-Rodríguez, E. Gómez-Lázaro, Á. Molina-García, J. A. Fuentes-Moreno
{"title":"Evaluation of frequency response of variable speed wind farms for reducing stability problems in weak grids","authors":"J. Villena-Lapaz, A. Vigueras-Rodríguez, E. Gómez-Lázaro, Á. Molina-García, J. A. Fuentes-Moreno","doi":"10.1109/PEMWA.2012.6316375","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316375","url":null,"abstract":"Maintaining the frequency within certain limits in a power system is a basic operational requirement as many loads may be very sensitive to frequency deviations. Increasing wind penetration in the power grid may lead to stability problems in isolated systems, or systems with weak interconnections with surrounding areas. Modern wind farms are based on variable speed wind turbines where the rotor speed and the electrical frequency are not coupled, thus, these farms do not add inertia to the system. At certain levels of wind penetration, the system inertia may become critically small, and the system may get unstable. In this work, some frequency response capabilities are incorporated into a wind farm. A validated wind model, developed by the authors, is used to obtain the wind series which is used for the simulations. Typical models of conventional generation power plants are used to fulfill the system operation requirements.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"31 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121000050","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}