{"title":"Improved design and control of proportional resonant controller for three-phase voltage source inverter","authors":"M. Ebad, B. Song","doi":"10.1109/PEMWA.2012.6316383","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316383","url":null,"abstract":"This paper presents an improved current control technique for a three-phase grid-connected DC/AC inverter using proportional resonant (PR) control. The proposed PR current control strategy is designed with tracking the reference current produced by an instantaneous power-based current reference generation method. In the controller the instantaneous power-based current reference generation method eliminates the delay in average power-based current reference generation methods, so a fast controller is required to maximize power delivery. The prosed PR controller also provides solutions for the drawbacks associated with conventional PI controllers that have slow dynamics and high distortion in the control feedback signal. For validation, simulation results of this grid-side control method are presented.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117141675","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
N. Miller, J. MacDowell, G. Chmiel, R. Konopinski, D. Gautam, G. Laughter, Dave Hagen
{"title":"Coordinated voltage control for multiple wind plants in Eastern Wyoming: Analysis and field experience","authors":"N. Miller, J. MacDowell, G. Chmiel, R. Konopinski, D. Gautam, G. Laughter, Dave Hagen","doi":"10.1109/PEMWA.2012.6316387","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316387","url":null,"abstract":"At high levels of wind power penetration, multiple wind plants may be the predominant generation resource over large geographic areas. Thus, not only do wind plants need to provide a high level of functionality, they must coordinate properly with each other. This paper describes the analysis and field testing of wind plant voltage controllers designed to improve system voltage performance through passive coordination. The described wind power plant controls can coordinate the real and reactive power response of multiple wind turbines and thereby make the plant function as a single “grid friendly” power generation source. For this application, involving seven large wind plants with predominantly GE wind turbines in Eastern Wyoming, the voltage portion of the controllers were configured and tuned to allow the collective reactive power response of multiple wind plants in the region to work well together. This paper presents the results of the initial configuration and tuning study, and the results of the subsequent field tuning and testing of the modified controls. The paper also presents some comparisons of the measured field performance with the stability simulation models, which show that the available wind plant models provide accurate, high fidelity results for actual operating conditions of commercial wind power plants.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126839221","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sudden torque collapse in energy-harvesting BLDC permanent magnet generators","authors":"A. Hartman, W. Lorimer","doi":"10.1109/PEMWA.2012.6316399","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316399","url":null,"abstract":"Brushless DC machines utilizing high energy neodymium magnets are commonly used as generators to produce electricity and provide braking torques to a shaft. We examine generators designed for lower varying operating speeds such as those used in micro-wind and human-driven dynamos. We focus on the phenomenon of a sudden loss of braking torque that occurs in smaller generators operated beyond a critical load and speed. We propose a new figure of merit beyond the traditional motor constant, Km, as critical to proper design of a BLDC generator for variable speed applications.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124866567","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A hybrid 2D-3D SVM control algorithm for three phase voltage source inverters","authors":"S. Albatran, Yong Fu, A. Albanna","doi":"10.1109/PEMWA.2012.6316357","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316357","url":null,"abstract":"This paper presents a hybrid 2D-3D space vector modulation algorithm to control the output voltage of three-phase four-wire voltage-sourced inverters in islanded power systems. The numerically efficient algorithm drives a balanced three-phase output voltage even when supplying an unbalanced load condition. In addition to the balanced voltage at the point of common coupling, the proposed algorithm offers synchronization controllability over the power angle of the inverter output, and hence provides control over power flow. Harmonic analysis of the inverter output voltage under the hybrid 2D-3D control algorithms yields a small THD of the line voltage. Various MATLAB/Simulink simulation studies are conducted to validate the effectiveness of the proposed algorithm.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122154985","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modeling and simulation of multi-terminal HVDC for wind power delivery","authors":"Ling Xu, Lingling Fan, Zhixin Miao","doi":"10.1109/PEMWA.2012.6316378","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316378","url":null,"abstract":"VSC-HVDC system is adopted more and more for its flexible control capability and multi-terminal topology. Offshore wind farms are becoming a preferred solution for wind power in many countries. The integration of offshore wind farms to grid is critical for efficient power delivery, since the transmission via long distance underwater could be a problem such as high percent power loss. The Multi-Terminal VSC-HVDC system is a suitable choice to integrate the offshore wind power with grid due to its advantages, such as flexible control capability and low power loss via DC cables. The contribution of this work is twofold: (i) detailed models of DFIG wind generators and MultiTerminal VSC-HVDC system are built and tested, and (ii) both normal operations and grid side ground fault are studied, and an approach to mitigate the over-voltage during fault is proposed and tested. The models and simulations are developed and tested via Matlab/SimPowerSystem.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128316687","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparison of salient pole and Permanent Magnet Synchronous Machines designed for wind turbines","authors":"G. Komurgoz, T. Gundogdu","doi":"10.1109/PEMWA.2012.6316381","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316381","url":null,"abstract":"The paper presents an analysis and comparison of synchronous electrical machines with salient pole with field winding and those with peripheral winding, presenting important advantages. Chinese export restrictions already reduce the reliability of planning for investments in permanent magnet (PM) wind turbines. Today, the production of PMs consumes the largest proportion of rare earth elements, with 40% of the rare earth-based magnets used for generators and other electrical machines. The cost and availability of NdFeB magnets will likely determine the production rate of PM generators. In this study, a Salient Pole Synchronous Machine (SPSM) and a Permanent Magnet Synchronous Machine (PMSM) are designed in a way that the plate values remain constant. The analysis results clearly indicate that SPSM designs would be attractive to wind power companies in terms of cost. Furthermore, the importance of the design of electrical machines and the determination of criteria are emphasized.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"500 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129855698","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Novel adaptive power control of a Direct-drive PM wind generation system in a micro grid","authors":"Lijun He, Yongdong Li, R. Harley","doi":"10.1109/PEMWA.2012.6316393","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316393","url":null,"abstract":"This paper presents an adaptive power control algorithm for a Direct-drive PM wind generation system in a micro grid. The strategy is based on the vector control algorithm for a two-level IGBT full power converter. The object of this novel control is to operate the wind generation, with a hybrid DC-AC link topology, either in Maximum Power Point Tracking (MPPT) mode, or non-MPPT mode with enhanced tracking performance. The simulation proves that the proposed MPPT algorithm is much faster, more robust and adaptive to changes of the environment than the conventional variable-step Hill Climbing Search (HCS) algorithm, while the non-MPPT module has a fast response to the change of the power demand and the environment, and accurate steady state response as well. Moreover, the result shows that the control strategy can switch between the MPPT and non-MPPT automatically.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134271530","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparison of different cooling systems for Doubly-Fed Wind Generator","authors":"Lizhong Huang, Yingming Zhang, Xueqing Feng","doi":"10.1109/PEMWA.2012.6316371","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316371","url":null,"abstract":"This paper presents the numerical simulation of flow-thermal coupling for 2 MW Doubly-Fed Induction Wind Generator (DFIG). With fundamental assumptions and corresponding boundary conditions, the number of grid is reduced to save calculation time. The temperature of internal air for different cooling system configuration is calculated with commercial FEA software FLUENT without assumption. Four cooling system configurations of DFIG are presented, analyzed and compared in details. The best cooling system configuration of DFIG has been found and will be used into our DFIG production.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"168 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132616946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A coordinated primary frequency regulation from Permanent Magnet Synchronous Wind Turbine Generation","authors":"Ziping Wu, Wenzhong Gao, Jianhui Wang, S. Gu","doi":"10.1109/PEMWA.2012.6316405","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316405","url":null,"abstract":"As a growing number of Permanent Magnet Synchronous Wind Turbine Generations (PMSG-WT) are integrated into the modern power grid, there has been a great concern for system operators who expects PMSG-WT to play an active role in the primary frequency regulation when frequency event occurs. However, PMSG-WTs are still unable to provide any additional active power in response to the system frequency change. In this work, a control scheme of coordinated frequency regulation for DFIG is redesigned and implemented into a PMSG-WT model by synthesizing the inertial control, over-rotor speed control and pitch angle control. Inertial control emulates the total inertia response of both wind turbine and generator to provide a short-term frequency support. According to the de-loaded optimum power extraction curve, the over-rotor speed and pitch angle controls are coordinated to maintain the reserved power and meanwhile assist the primary frequency regulation in a long-term period. The coordinated control strategy of PMSG-WT comprises the low, medium and high wind speed modes. By this means, the comprehensive control method will promote the PMSG-based wind farms to effectively participate in the system frequency regulation under a full scope of wind speed conditions.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115042057","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sang-Wook Sohn, A. Allen, S. Kulkarni, W. Grady, S. Santoso
{"title":"Event detection method for the PMUs synchrophasor data","authors":"Sang-Wook Sohn, A. Allen, S. Kulkarni, W. Grady, S. Santoso","doi":"10.1109/PEMWA.2012.6316400","DOIUrl":"https://doi.org/10.1109/PEMWA.2012.6316400","url":null,"abstract":"The objective of the paper is to present an innovative method for event detection. The data is collected using a PMU network installed to provide wide-area monitoring and analysis of Texas' bulk power system. Grid events are detected using a combination of simple statstical algorithms, singular point detection with residual modeling, short time Fourier transform and linear regression. The performance of the proposed method is shown through the results of analysis on two types of actual events.","PeriodicalId":375595,"journal":{"name":"2012 IEEE Power Electronics and Machines in Wind Applications","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121198393","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}