Journal of Electronics, Electromedical Engineering, and Medical Informatics最新文献

筛选
英文 中文
Waterbath Design equipped With Temperature Distribution Monitor 配备温度分布监视器的水浴设计
Journal of Electronics, Electromedical Engineering, and Medical Informatics Pub Date : 2019-07-22 DOI: 10.35882/JEEEMI.V1I1.3
Febri Indiani, D. Titisari, L. Lamidi
{"title":"Waterbath Design equipped With Temperature Distribution Monitor","authors":"Febri Indiani, D. Titisari, L. Lamidi","doi":"10.35882/JEEEMI.V1I1.3","DOIUrl":"https://doi.org/10.35882/JEEEMI.V1I1.3","url":null,"abstract":"Waterbath is a device used to create a constant temperature. This tool is used to incubates in microbiology analysis. Temperature is maintained according to the desired range. The heating element is controlled by the heater driver. This module is created by using Arduino Atmega 328 as a minimum system and time controller, Using a PID controller as temperature control, and using a DS18B20 sensor as a temperature sensor. The design of this study uses pre-experimental methods after only design research. The measurement results are done by comparing the module with a standard measurement instrument that produces the biggest % error in setting temperature of 37 ˚C which is equal to 1.21%, it is related to the boundary between water temperature and temperature setting too short which is affected by the DS18B20 temperature sensor reader that need time, to get a stable temperature reading. The minimum % error located at 60 ˚C, because to reach the temperature setting needs a long time so that DS18B20 the sensor reading is stable of setting temperature which is equal to 0.11%. The value % error of the timer is 3.4 % which the amount of the error is affected by the number of DS18B20 which is used and the delay from the microcontroller. Based on the results obtained this module can be used properly because still on the maximum limit error value less than 5%.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130509127","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Five Channel Temperature Calibrator Using Thermocouple Sensors Equipped With Data Storage 使用配备数据存储的热电偶传感器的五通道温度校准器
Journal of Electronics, Electromedical Engineering, and Medical Informatics Pub Date : 2019-07-22 DOI: 10.35882/JEEEMI.V1I1.1
Rizkiyatussani Rizkiyatussani, Her Gumiwang Ariswati, Syaifudin Syaifudin
{"title":"Five Channel Temperature Calibrator Using Thermocouple Sensors Equipped With Data Storage","authors":"Rizkiyatussani Rizkiyatussani, Her Gumiwang Ariswati, Syaifudin Syaifudin","doi":"10.35882/JEEEMI.V1I1.1","DOIUrl":"https://doi.org/10.35882/JEEEMI.V1I1.1","url":null,"abstract":"A temperature calibration device is a tool used to measure the accuracy of a temperature-related device such as a sterilisator. This temperature calibration device is needed when the temperature in the sterilisator is not linear. In this calibration tool the sensor used is a type-k thermocouple that is inserted into the media to be measured then the temperature results will be read. This tool is designed using pre-experimental methods with the type of after only design research. In this tool is equipped with storage on the micro sd card and also conversion mode to convert temperature results from Celsius to Rheamur, Farenheit and Kelvin. Temperature results will be displayed on a 4x20 LCD and processed using Arduino UNO. This module can be used in medical equipment calibration laboratories. After testing the thesis module with a comparison device from BPFK, the biggest error is obtained at 1% at 50 ° Celsius, 100 ° Celsius and 150 ° Celsius. The smallest percentage of error is 0% at 50 ° Celsius and 150 ° Celsius. It can be concluded that the tool \"Temperature Calibrator (5 Channels) Using Thermocouple Equipped with Data Storage.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129915115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信