Journal of Radiation Protection and Research最新文献

筛选
英文 中文
Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels 带门控通道的移动ZnS(Ag)/PTV阵列和手持PVT杆快速测量表层土壤中总α / β和90Sr活性的初步研究
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-12-29 DOI: 10.14407/jrpr.2021.00178
Chanki Lee, H. Kim
{"title":"Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels","authors":"Chanki Lee, H. Kim","doi":"10.14407/jrpr.2021.00178","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00178","url":null,"abstract":"Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq· g-1, 3 Bq· g-1, and 10 Bq· g-1 were prepared and hardened by flocculation.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"8 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75407634","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Mass Interception Fractions and Weathering Half-lives of Iodine-131 and Radiocesium in Leafy Vegetables Observed after the Fukushima Daiichi Nuclear Power Plant Accident 福岛第一核电站事故后叶菜中碘-131和放射性铯的质量拦截分数和风化半衰期
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-12-29 DOI: 10.14407/jrpr.2021.00164
K. Tagami, S. Uchida
{"title":"Mass Interception Fractions and Weathering Half-lives of Iodine-131 and Radiocesium in Leafy Vegetables Observed after the Fukushima Daiichi Nuclear Power Plant Accident","authors":"K. Tagami, S. Uchida","doi":"10.14407/jrpr.2021.00164","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00164","url":null,"abstract":"Background: This study was carried out to provide environmental transfer parameter values to estimate activity concentrations of these radionuclides in agricultural crops when direct contamination occurred. Materials and Methods: Mass interception fractions ( F B s) and weathering half-lives ( T w s) of 131 I and radiocesium were calculated using openly available monitoring data obtained after the Fukushima Daiichi Nuclear Power Plant accident. F B is the ratio between the initial radioactivity concentration of a radionuclide retained by the edible part of the plant (Bq ‧ kg -1 fresh weight [FW]) and the amount of deposited radionuclide in that area (Bq ‧ m -2 ). T w values can be calculated using activity concentrations of crops decreased with time after the initial contamination. Results and Discussion: Calculated F B and T w values for 131 I and radiocesium were mostly obtained for leafy vegetables. The analytical results showed that there was no difference of F B s between 131 I and radiocesium by t -test; geometric mean values for leafy vegetables cultivated under outdoor conditions were 0.058 and 0.12 m 2 ‧ kg -1 FW, respectively. Geometric mean T w value of 131 I in leafy vegetables grown under outdoor conditions was 8.6 days, and that of radiocesium was 6.6 days; there was no significant difference between T w values of these radionuclides by Wilcoxon rank sum test. Conclusion: There was no difference between 131 I and radiocesium for F B s and T w s. By using these factors, we would be able to carry out a rough estimation of the activity concentrations of 131 I and radiocesium in the edible part of leafy crops when a nuclear accident occurred.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"32 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84795409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Age-Specific Thyroid Internal Dose Estimation for Koreans 韩国人年龄特异性甲状腺内剂量估计
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-12-25 DOI: 10.14407/jrpr.2021.00066
Tae-Eun Kwon, Seokwon Yoon, Wi-Ho Ha, Yoonsun Chung, Y. Jin
{"title":"Age-Specific Thyroid Internal Dose Estimation for Koreans","authors":"Tae-Eun Kwon, Seokwon Yoon, Wi-Ho Ha, Yoonsun Chung, Y. Jin","doi":"10.14407/jrpr.2021.00066","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00066","url":null,"abstract":"Background: The International Commission on Radiological Protection is preparing to pro-vide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. There-fore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129 I and 131 I were considerably lower than those calculated for the world population (25%–76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"94 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89672372","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Machine Learning-Based Radioisotope Identifiers for Plastic Scintillation Detector 基于机器学习的塑料闪烁探测器放射性同位素标识符比较
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-11-27 DOI: 10.14407/jrpr.2021.00206
Byoungil Jeon, Jongyul Kim, Yonggyun Yu, Myungkook Moon
{"title":"Comparison of Machine Learning-Based Radioisotope Identifiers for Plastic Scintillation Detector","authors":"Byoungil Jeon, Jongyul Kim, Yonggyun Yu, Myungkook Moon","doi":"10.14407/jrpr.2021.00206","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00206","url":null,"abstract":"Background: Identification of radioisotopes for plastic scintillation detectors is challenging because their spectra have poor energy resolutions and lack photo peaks. To overcome this weak-ness, many researchers have conducted radioisotope identification studies using machine learning algorithms; however, the effect of data normalization on radioisotope identification has not been addressed yet. Furthermore, studies on machine learning-based radioisotope identifiers for plastic scintillation detectors are limited. Materials and Methods: In this study, machine learning-based radioisotope identifiers were implemented, and their performances according to data normalization methods were compared. Eight classes of radioisotopes consisting of combinations of 22 Na, 60 Co, and 137 Cs, and the background, were defined. The training set was generated by the random sampling technique based on probabilistic density functions acquired by experiments and simulations, and test set was acquired by experiments. Support vector machine (SVM), artificial neural network (ANN), and convolutional neural network (CNN) were implemented as radioisotope identifiers with six data normalization methods, and trained using the generated training set. Results and Discussion: The implemented identifiers were evaluated by test sets acquired by experiments with and without gain shifts to confirm the robustness of the identifiers against the gain shift effect. Among the three machine learning-based radioisotope identifiers, prediction accuracy followed the order SVM > ANN > CNN, while the training time followed the order SVM > ANN > CNN. Conclusion: The prediction accuracy for the combined test sets was highest with the SVM. The CNN exhibited a minimum variation in prediction accuracy for each class, even though it had the lowest prediction accuracy for the combined test sets among three identifiers. The SVM exhibited the highest prediction accuracy for the combined test sets, and its training time was the shortest among three identifiers.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"48 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78281906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
A Review of Organ Dose Calculation Tools for Patients Undergoing Computed Tomography Scans 计算机断层扫描患者的器官剂量计算工具综述
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-11-05 DOI: 10.14407/jrpr.2021.00136
Choonsik Lee
{"title":"A Review of Organ Dose Calculation Tools for Patients Undergoing Computed Tomography Scans","authors":"Choonsik Lee","doi":"10.14407/jrpr.2021.00136","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00136","url":null,"abstract":"Background: Computed tomography (CT) is one of the crucial diagnostic tools in modern medicine. However, careful monitoring of radiation dose for CT patients is essential since the procedure involves ionizing radiation, a known carcinogen. Materials and Methods: The most desirable CT dose descriptor for risk analysis is the organ absorbed dose. A variety of CT organ dose calculators currently available were reviewed in this article. Results and Discussion: Key common elements included in CT dose calculators were discussed and compared, such as computational human phantoms, CT scanner models, organ dose database, effective dose calculation methods, tube current modulation modeling, and user interface platforms. Conclusion: It is envisioned that more research needs to be conducted to more accurately map CT coverage on computational human phantoms, to automatically segment organs and tissues for patient-specific dose calculations, and to accurately estimate radiation dose in the cone beam computed tomography process during image-guided radiation therapy.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"82 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73676764","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity 高清晰度双曝光x射线成像双能信号与噪声研究
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-10-15 DOI: 10.14407/jrpr.2021.00017
Boram Song, Changsoo Kim, Junwoo Kim
{"title":"Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity","authors":"Boram Song, Changsoo Kim, Junwoo Kim","doi":"10.14407/jrpr.2021.00017","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00017","url":null,"abstract":"Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of doubleexposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"103 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90520778","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Lifetime Risk Assessment of Lung Cancer Incidence for Nonsmokers in Japan Considering the Joint Effect of Radiation and Smoking Based on the Life Span Study of Atomic Bomb Survivors 考虑辐射和吸烟共同影响的日本非吸烟者肺癌发病率终生风险评估——基于原子弹幸存者寿命研究
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-09-30 DOI: 10.14407/jrpr.2020.00255
K. Shimada, M. Kai
{"title":"Lifetime Risk Assessment of Lung Cancer Incidence for Nonsmokers in Japan Considering the Joint Effect of Radiation and Smoking Based on the Life Span Study of Atomic Bomb Survivors","authors":"K. Shimada, M. Kai","doi":"10.14407/jrpr.2020.00255","DOIUrl":"https://doi.org/10.14407/jrpr.2020.00255","url":null,"abstract":"Background: The lifetime risk of lung cancer incidence due to radiation for nonsmokers is overestimated because of the use of the average cancer baseline risk among a mixed population, including smokers. In recent years, the generalized multiplicative (GM)-excess relative risk (ERR) model has been developed in the life span study of atomic bomb survivors to consider the joint effect of radiation and smoking. Based on this background, this paper discusses the issues of radiation risk assessment considering smoking in two parts.Materials and Methods: In Part 1, we proposed a simple method of estimating the baseline risk for nonsmokers using current smoking data. We performed sensitivity analysis on baseline risk estimation to discuss the birth cohort effects. In Part 2, we applied the GM-ERR model for Japanese smokers to calculate lifetime attributable risk (LAR). We also performed a sensitivity analysis using other ERR models (e.g., simple additive (SA)-ERR model).Results and Discussion: In Part 1, the lifetime baseline risk from mixed population including smokers to nonsmokers decreased by 54% (44%–60%) for males and 24% (18%–29%) for females. In Part 2, comparison of LAR between SA- and GM-ERR models showed that if the radiation dose was ≤200 mGy or less, the difference between these ERR models was within the standard deviation of LAR due to the uncertainty of smoking information.Conclusion: The use of mixed population for baseline risk assessment overestimates the risk for lung cancer due to low-dose radiation exposure in Japanese males.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"7 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84356193","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients 透视x射线:疑似COVID-19患者的移动成像剂量学和图像质量
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-09-30 DOI: 10.14407/jrpr.2020.00269
Alexandra Schelleman, Chris Boyd
{"title":"X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients","authors":"Alexandra Schelleman, Chris Boyd","doi":"10.14407/jrpr.2020.00269","DOIUrl":"https://doi.org/10.14407/jrpr.2020.00269","url":null,"abstract":"Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks.Materials and Methods: Two exposure levels were examined, a “typical” mobile exposure of 100 kVp/1.6 mAs and a “high” exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility.Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 μGy to 67.82 μGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings.Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"15 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90311343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determination of 226Ra in TENORM Sample Considering Radon Leakage Correction 考虑氡泄漏校正的TENORM样品中226Ra的测定
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-09-30 DOI: 10.14407/jrpr.2021.00087
Sooyeon Lim, N. Syam, Seongjin Maeng, Sang Hoon Lee
{"title":"Determination of 226Ra in TENORM Sample Considering Radon Leakage Correction","authors":"Sooyeon Lim, N. Syam, Seongjin Maeng, Sang Hoon Lee","doi":"10.14407/jrpr.2021.00087","DOIUrl":"https://doi.org/10.14407/jrpr.2021.00087","url":null,"abstract":"Background: Phosphogypsum is material produced as a byproduct in fertilizer industry and is generally used for building materials. This material may contain enhanced radium-226 (226Ra) activity concentration compared to its natural concentration that may lead to indoor radon accumulation. Therefore, an accurate measurement method is proposed in this study to determine 226Ra activity concentration in phosphogypsum sample, considering the potential radon leakage from the sample container.Materials and Methods: The International Atomic Energy Agency (IAEA) phosphogypsum reference material was used as a sample in this study. High-purity germanium (HPGe) gamma spectrometry was used to measure the activity concentration of the 226Ra decay products, i.e., 214Bi and 214Pb. Marinelli beakers sealed with three different sealing methods were used as sample containers. Due to the potential leakage of radon from the Marinelli beaker (MB), correction to the activity concentration resulted in gamma spectrometry is needed. Therefore, the leaked fraction of radon escaped from the sample container was calculated and added to the gamma spectrometry measured values.Results and Discussion: Total activity concentration of 226Ra was determined by summing up the activity concentration from gamma spectrometry measurement and calculated concentration from radon leakage correction method. The results obtained from 214Bi peak were 723.4 ± 4.0 Bq· kg-1 in MB1 and 719.2 ± 3.5 Bq· kg-1 in MB2 that showed about 5% discrepancy compared to the certified activity. Besides, results obtained from 214Pb peak were 741.9 ± 3.6 Bq· kg-1 in MB1 and 740.1 ± 3.4 Bq· kg-1 in MB2 that showed about 2% difference compared to the certified activity measurement of 226Ra concentration activity.Conclusion: The results show that radon leakage correction was calculated with insignificant discrepancy to the certified values and provided improvement to the gamma spectrometry. Therefore, measuring 226Ra activity concentration in TENORM (technologically enhanced naturally occurring radioactive material) sample using radon leakage correction can be concluded as a convenient and accurate method that can be easily conducted with simple calculation.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"70 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84096942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The IRPA Young Generation Network: Activity Report from the Middle of 2018 to the Beginning of 2021 IRPA青年一代网络:2018年年中至2021年初的活动报告
IF 0.5
Journal of Radiation Protection and Research Pub Date : 2021-07-23 DOI: 10.14407/JRPR.2021.00080
S. Andresz, Akihiro Sakoda, Wi-Ho Ha, F. Kabrt, Takahiko Kono, Marina Sáez Muñoz, Omar Nusrat, C. Papp, Rui Qiu, P. Bryant
{"title":"The IRPA Young Generation Network: Activity Report from the Middle of 2018 to the Beginning of 2021","authors":"S. Andresz, Akihiro Sakoda, Wi-Ho Ha, F. Kabrt, Takahiko Kono, Marina Sáez Muñoz, Omar Nusrat, C. Papp, Rui Qiu, P. Bryant","doi":"10.14407/JRPR.2021.00080","DOIUrl":"https://doi.org/10.14407/JRPR.2021.00080","url":null,"abstract":"Since its establishment in 2018, the Young Generation Network (YGN) has been dedicated, with support of the International Radiation Protection Association (IRPA), to a variety of activities to promote communication, collaboration and professional development of students and young professionals in the area of radiation protection and its allied fields. This article reports our recent activities from the middle of 2018 to the beginning of 2021, with highlights on some important events: “Joint JHPS-SRP-KARP Workshop of Young Generation Network” (December 2019 in Japan);contribution to “Nuclear Energy Agency Workshop on Optimization: Rethinking the Art of Reasonable” (January 2020 in Portugal);survey on the impact of coronavirus disease 2019 (COVID-19) on radiation protection among IRPA YGN members (March 2020);and contribution to IRPA15 (15th International Congress of the IRPA;January–February 2021, online). The discussion and insight obtained from each activity are also summarized. The IRPA YGN will aim to achieve its on-going activities and continue to follow the ways paved in the Strategic Agenda and despite the challenges raised by the COVID-19 pandemic. Namely, running an international survey (for example, on the usage of social media in radiation protection, and on the long-term consequences of the COVID-19 pandemic), engaging national YGNs, extending the network, finding new relationships with networks with an interest in the young generation and participation in (remote) events will be aspired for. Copyright © 2021 The Korean Association for Radiation Protection.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"77 1","pages":""},"PeriodicalIF":0.5,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81554219","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信