2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)最新文献

筛选
英文 中文
PXI-based non-contact vital sign detection system 基于pxi的非接触式生命体征检测系统
S. Banerjee, Changzhan Gu, Changzhi Li
{"title":"PXI-based non-contact vital sign detection system","authors":"S. Banerjee, Changzhan Gu, Changzhi Li","doi":"10.1109/BIOWIRELESS.2014.6827730","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827730","url":null,"abstract":"This paper presents a novel noncontact vital sign detection (VSD) system, which integrates an entire radar transceiver along with advanced signal processing algorithms in one compact PXI (Peripheral Component Interconnect eXtensions for Instrumentation) system. Realtime signal processing has been implemented using automatic DC calibration based on compressed sensing algorithm and ‘differentiate and cross-multiply’ (DACM) demodulation algorithm. Experimental results show that the proposed compact instrument based radar is able to measure respiration motions with simple hardware configuration. This facilitates many proof-of-concept studies for noncontact vital sign detection.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"210 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130158417","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Design and implementation of wearable RFID tag for real-time ubiquitous medical care 面向实时普适医疗的可穿戴RFID标签的设计与实现
Yeh-Cheng Chen, Hung-Min Sun, Ruey-Shun Chen
{"title":"Design and implementation of wearable RFID tag for real-time ubiquitous medical care","authors":"Yeh-Cheng Chen, Hung-Min Sun, Ruey-Shun Chen","doi":"10.1109/BIOWIRELESS.2014.6827735","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827735","url":null,"abstract":"With the upcoming aging society and emerging of some newly discovered chronic diseases, the demand of hospital nursing for elderly patients had been significantly increased. It is a critical issue for health worker to provide a comprehensive, proactive health care in hospital, especially for those vulnerable patients who are unable to speak or behave for themselves. This study proposes an innovative, wearable RFID tag which embedded body temperature monitoring sensor, and equipped with automatic identification and localization, real-time emergency notification for health care workers. Additionally, operating with the intelligent backend system architecture, this system can also provide immediate physician advices in case if emergency situation happens without doctor near the site. The result of this study provides a ubiquitous medical care throughout whole hospital, and the new-invented tag may bring a significant change to normal health care process, especially in patient care.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131366757","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Movement-immune respiration monitoring using automatic DC-correction algorithm for CW Doppler radar system 连续波多普勒雷达系统运动免疫呼吸自动校正算法
Yiran Li, Guochao Wang, Changzhan Gu, Changzhi Li
{"title":"Movement-immune respiration monitoring using automatic DC-correction algorithm for CW Doppler radar system","authors":"Yiran Li, Guochao Wang, Changzhan Gu, Changzhi Li","doi":"10.1109/BIOWIRELESS.2014.6827740","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827740","url":null,"abstract":"Doppler radar has the capability to remotely monitor human respiration. However, in real applications random body movements during measurement will cause drift of “DC” level in the experiment results. Also, the dc level will shift slowly with the temperature change of the radar circuit. Those DC drifts will cause inaccurate measurement results. To solve the dc drift issue during the experiments, an automatic DC-correction algorithm is developed. Experiment results show that this algorithm eliminates undesirable DC drifts and offset while recovering useful information of the original respiration signal. It is able to provide reliable respiration measurement even if there are large body movements that otherwise overwhelm the desired signal.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124925020","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
SAR evaluation of ultra wideband (UWB) textile antennas 超宽带(UWB)纺织天线SAR评价
P. Soh, G. Vandenbosch, F. H. Wee, M. Mercuri, A. van den Bosch, M. Martínez-Vázquez, D. Schreurs
{"title":"SAR evaluation of ultra wideband (UWB) textile antennas","authors":"P. Soh, G. Vandenbosch, F. H. Wee, M. Mercuri, A. van den Bosch, M. Martínez-Vázquez, D. Schreurs","doi":"10.1109/BIOWIRELESS.2014.6827725","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827725","url":null,"abstract":"This work presents a systematic investigation of the Specific Absorption Rate (SAR) of two ultra wideband (UWB) textile antennas. These popular UWB topologies are implemented using similar materials and evaluated at a common frequency point for comparison purposes in a certified SAR facility. Evaluations indicate that the antenna ground plane area and the distance to the body phantom also seriously affects SAR levels. This evaluation has also quantified the SAR measurement repeatability at various distances at a maximum of 10 %.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123740882","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
A low switching frequency AC-DC boost converter for wireless powered miniaturized implants 一种用于无线供电微型植入物的低开关频率AC-DC升压转换器
Hao Jiang, Ben Lariviere, Di Lan, Junmin Zhang, Jing Wang, R. Fechter, M. Harrison, Shuvo Roy
{"title":"A low switching frequency AC-DC boost converter for wireless powered miniaturized implants","authors":"Hao Jiang, Ben Lariviere, Di Lan, Junmin Zhang, Jing Wang, R. Fechter, M. Harrison, Shuvo Roy","doi":"10.1109/BIOWIRELESS.2014.6827739","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827739","url":null,"abstract":"Providing electrical power to an implantable microelectronic device (IMD) via wireless power transfer technology is critical to implant's efficacy. The inductive coupling based wireless power transfer technology has been the primary approach to remotely power an IMD [1]. Reducing the coil size and improving efficiency are the two primary design goals for the power harvesting component in an IMD. A pulse-width-modulated (PWM) boost converter has been demonstrated to efficiently convert the low-voltage (much less than the regular diode's turn-on voltage) AC power generated by a miniaturized receiving coil to a desired high-voltage DC power [2]. In [2], the switching frequency of the PWM is much higher than the frequency of the input AC power. The high switching frequency not only dissipates more power during the switching, which deteriorates the converter's overall efficiency, but also prevents the circuit from handling the high-frequency input AC power. In this paper, a low switching frequency AC to DC boost converter is demonstrated. By aligning the PWM signal with the input AC, the boost converter is able to convert the AC power, whose amplitude is 500 mV at the open-circuit condition, to a >5 V DC output. The converter demonstrated in this paper has the potential to significantly improve the conversion efficiency by reducing the dissipated power associated with the PWM switch, especially when the input AC is at higher frequencies.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133179157","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Radiation efficiency of planar implantable antennas at ISM band 平面植入式天线在ISM波段的辐射效率
M. Tofighi, Shi-Min Huang
{"title":"Radiation efficiency of planar implantable antennas at ISM band","authors":"M. Tofighi, Shi-Min Huang","doi":"10.1109/BIOWIRELESS.2014.6827724","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827724","url":null,"abstract":"Most attentions regarding the performance of implantable antennas have been paid to the reflection coefficient (S11 with respect to 50 Ω), bandwidth, and far-field radiation pattern, while little effort has been dedicated to investigate the radiation efficiency during the implant design process. Analysis of two slot-type (annular and meandered) and two strip-type (ring and meandered PIFA) antennas embedded in muscle is presented in this paper at 2.4 GHz ISM band. It reveals that the slot types have superior performance in terms of their radiation efficiency. Also, the radiation efficiency is improved by operating away from the resonance, mostly where the admittance is inductive. The radiation efficiency may vary over an order of magnitude or more depending on the choice of the antenna and its resonance point, a fact that deserves further attention.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128331928","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A power consumption optimized reflective in-ear pulse oximeter for mobile health monitoring 用于移动健康监测的功耗优化反射式耳内脉搏血氧仪
B. Venema, Matthias Simon Wolke, V. Blazek, S. Leonhardt
{"title":"A power consumption optimized reflective in-ear pulse oximeter for mobile health monitoring","authors":"B. Venema, Matthias Simon Wolke, V. Blazek, S. Leonhardt","doi":"10.1109/BIOWIRELESS.2014.6827738","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827738","url":null,"abstract":"An unobtrusive, mobile in-ear pulse oximeter for body sensor network with predictive power-management optimization algorithm is presented. The system can be connected via Bluetooth to a smartphone for online visualization of vital signs, recording or telemonitoring via UMTS (Universal Mobile Telecommunications System). The work focuses on energy saving strategies. Main part of the work is a significant reduction of the PPG-on-time by means of a real-time heart rate estimation routine. The concept is tested on sleep apnea patients with 96.8 % correct estimated heart events at a mean power consumption of 103 mW.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"40 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131471818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A mobile and wireless approach for cardiac output monitoring 心输出量监测的移动和无线方法
D. Teichmann, Thorsten Bartelt, S. Leonhardt, M. Walter
{"title":"A mobile and wireless approach for cardiac output monitoring","authors":"D. Teichmann, Thorsten Bartelt, S. Leonhardt, M. Walter","doi":"10.1109/BIOWIRELESS.2014.6827737","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827737","url":null,"abstract":"This paper presents a novel device for cardiac output monitoring based on electromagnetic coupling between the sensor and the thoracic tissue. The device works in a noncontact way and is integrated into a shirt. Since the device is wearable, mobile, wireless, and easily operated, it would allow the incorporation of cardiac output measurements into home monitoring systems.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"24 11","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120841802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Optimal design of energy efficient inductive links for powering implanted devices 为植入设备供电的高能效感应链路的优化设计
F. L. Cabrera, F. R. de Sousa
{"title":"Optimal design of energy efficient inductive links for powering implanted devices","authors":"F. L. Cabrera, F. R. de Sousa","doi":"10.1109/BIOWIRELESS.2014.6827731","DOIUrl":"https://doi.org/10.1109/BIOWIRELESS.2014.6827731","url":null,"abstract":"This paper presents a method for optimal design of inductive links using geometric programming. The optimization proposed allows the inclusion of all geometric and electric constraints associated to the link. As an example, we design the dimensions of the primary inductor and frequency when the secondary inductor has a diameter of 4 mm. The set of inductors designed for a distance of 15 mm was implemented. The maximum efficiency measured is 30% at 415 MHz, which agrees with the expected values.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123879545","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信