Low voltage DC distribution - are we ready yet? 低压直流配电,准备好了吗?
R. Kunnath, K. Vasudevan, A. Jhunjhunwala, D. Jalihal, Prabhjot Kaur, M. Kumaravel
{"title":"Low voltage DC distribution - are we ready yet?","authors":"R. Kunnath, K. Vasudevan, A. Jhunjhunwala, D. Jalihal, Prabhjot Kaur, M. Kumaravel","doi":"10.1109/SGBC.2016.7935990","DOIUrl":"https://doi.org/10.1109/SGBC.2016.7935990","url":null,"abstract":"With the increasing use of power electronics in all types of appliances, and with the increasing penetration of solar PV, distribution of power in the DC form is becoming attractive. This paper brings together various concerns that have been expressed in DC distribution at low voltages for consumption in domestic and other building needs. The paper presents various arguments and attempts to arrive at a solution from various points of view. A suitable voltage level of 48 V, and a suitable distribution scheme are presented along with some field experiences of installation of such systems.","PeriodicalId":339120,"journal":{"name":"2016 First International Conference on Sustainable Green Buildings and Communities (SGBC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117163339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Energy efficiency in lighting: AC vs DC LED lights 照明的能源效率:交流与直流LED灯
A. Jhunjhunwala, K. Vasudevan, Prabhjot Kaur, B. Ramamurthi, Kumaravel, S. Bitra, Kushant Uppal
{"title":"Energy efficiency in lighting: AC vs DC LED lights","authors":"A. Jhunjhunwala, K. Vasudevan, Prabhjot Kaur, B. Ramamurthi, Kumaravel, S. Bitra, Kushant Uppal","doi":"10.1109/SGBC.2016.7936068","DOIUrl":"https://doi.org/10.1109/SGBC.2016.7936068","url":null,"abstract":"This paper focuses on LED lights that are powered by Direct Current source. A comparison of Alternating Current(AC) and Direct Current(DC) LED lights efficiencies has been done. We have also evaluated the driver efficiency and thermal stability for both AC and DC lights. Experiments have been conducted on the life-test of DC LED tube-light. The result shows that DC LED lights are more efficient and reliable than AC lights.","PeriodicalId":339120,"journal":{"name":"2016 First International Conference on Sustainable Green Buildings and Communities (SGBC)","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122714356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Power line carrier communication based low cost power monitoring and management system 基于电力线载波通信的低成本电力监控与管理系统
Vidyalaxmi Dani, D. Jalihal, S. Sampoornam, R. K. Chowdhury, S. Vasan, S. Ramanan, Ragavedhni K R
{"title":"Power line carrier communication based low cost power monitoring and management system","authors":"Vidyalaxmi Dani, D. Jalihal, S. Sampoornam, R. K. Chowdhury, S. Vasan, S. Ramanan, Ragavedhni K R","doi":"10.1109/SGBC.2016.7936054","DOIUrl":"https://doi.org/10.1109/SGBC.2016.7936054","url":null,"abstract":"Smart meter is an advanced energy meter which not only measures the electrical energy consumption, but also provides real time data on power consumed by electrical loads. Any smart meter needs an infrastructure, wired/wireless, for data communication with the central server. To enable this two-way communication link, we propose a narrowband Power Line Communication (PLC) system operating at a rate of few kbps and this can be deployed over existing outdoor/indoor power lines. Our design demonstrates reusing the existing wired electrical network to provide communication between the smart meter and a central server. A low-cost dedicated hardware for measuring the power usage of electrical appliance is designed. Further, a user interface is developed to remotely access the power usage measurements stored at the central hub database with features of power management. With the usage data at hand, smart decisions can be made in saving energy and, reducing carbon foot-prints. Our design uses low cost and off the shelf devices and no additional wiring as it communicates over the existing power line infrastructure.","PeriodicalId":339120,"journal":{"name":"2016 First International Conference on Sustainable Green Buildings and Communities (SGBC)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123788114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信