Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference最新文献

筛选
英文 中文
Fixation of osteochondral fractures with absorbable pins 可吸收针固定骨软骨骨折
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514431
B. Lurate, D. P. Mukherjee, R. N. Kruse, J. Albright
{"title":"Fixation of osteochondral fractures with absorbable pins","authors":"B. Lurate, D. P. Mukherjee, R. N. Kruse, J. Albright","doi":"10.1109/SBEC.1995.514431","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514431","url":null,"abstract":"Smaller osteschondral fragments containing little or no cortex present difficult treatment dilemma. Metallic screws or Kirschner wires often require subsequent removal either as part of the original operative plan or because of problems such as loosening and/or cartilage erosion. An attractive alternative would be a biodegradable implant that would transfix an osteochondral fragment with minimal violation of the articular surface. The objectives of this study are (1) to compare osteochondral fracture fixation of 2mm polyglycolic acid (PGA) absorbable pins (Acufex, Manfield, Mass) with that of Kirschner wires (K-wires) in cadavers, (2) to review patient data where osteochondral fractures were fixed with PGA-pins. The following conclusions were obtained: (1) Cadaver Studies: The biomechanical parameters of the osteochondral fractures fixed with absorbable PGA pins were not statistically different from those fixed with K-wires. Based on these laboratory studies it appears that fixation of osteochondral fractures with bioabsorbable PGA pins may offer a viable alternative to the use of K-wires. (2) Clinical Cases: A short follow up period with four clinical cases indicated that in carefully selected injuries, fixation with absorbable pins could become the treatment of choice of smaller joints. For severely comminuted fractures about major joints, PGA absorbable pins may be an adjunct to metal fixation.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123805884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A new hemostasis device for hemodialysis patients 一种用于血液透析患者的新型止血装置
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514507
J.R. Tamarapalli, J. Lemons, J. Dockery, B. Burdick
{"title":"A new hemostasis device for hemodialysis patients","authors":"J.R. Tamarapalli, J. Lemons, J. Dockery, B. Burdick","doi":"10.1109/SBEC.1995.514507","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514507","url":null,"abstract":"The major main aims of the study were to: 1. develop a device to obtain a better result compared to manual puncture site compression; 2. develop a stable device which would not slip during application; 3. help all dialysis patients, especially those patients who are unable to hold their needle puncture sites; 4. relieve the nurse to attend to other activities; and 5. to better utilize the whole length of the graft thereby preventing recirculation of non-dialysis blood and repeatedly puncturing a short length of the graft. A device was fabricated from a light weight plastic material with a C shape. This contour allowed conformity to the various shapes of the dialysis access limbs. The device included a rotatable threaded shaft, with which it was possible to achieve a controlled pressure on the fistula or graft. An internal (shaft) safety mechanism was incorporated so that undue pressure could not be applied on the vascular graft. The device was designed to be stable and comfortable. The puncture site contact surface of the device was designed to be disposable and to minimize any possibilities of cross contamination. Different sizes of clamps were made to best accommodate the various sizes of upper and lower access limbs. An initial clinical study on 25 patients conducted by the dialysis nurses at the University of Alabama at Birmingham and Sylacauga dialysis center, Sylacaga, Alabama demonstrated no problems with the C clamp system.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131287240","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measurement of the intracranial buffering capacity of the cerebrospinal fluid system 脑脊液系统颅内缓冲能力的测定
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514495
E. Walsh, A. Schettini
{"title":"Measurement of the intracranial buffering capacity of the cerebrospinal fluid system","authors":"E. Walsh, A. Schettini","doi":"10.1109/SBEC.1995.514495","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514495","url":null,"abstract":"Intracranial pressure (ICP) monitoring of cerebrospinal fluid (CSF) dynamics is used in the management of neurological conditions associated with intracranial hypertension. An extension of this is the measurement of the system pressure-volume index (PVI) which is intended to provide an indication of the intracranial buffering capacity, used in predicting the change in ICP when the craniospinal system is subject to further volume increments. Alternative means of identifying the intracranial buffering capacity involve the determination of the system compliance (C) or the volume-pressure response (VPR). Here, the authors contrast these measurements in the case of controlled intracranial mass expansion and, further, relate the determination of brain tissue response derived from these measurements to a more direct method of measuring brain tissue properties.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127570153","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative biomechanical analysis of supracondylar femur fracture fixation: locked intramedullary nail vs. 95/spl deg/ angled plate 股骨髁上骨折固定的生物力学分析:锁定髓内钉与95/spl度/角度钢板
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514489
M. E. Harrow, S. M. David, R. Peindl, S. Frick, J. Kellam
{"title":"Comparative biomechanical analysis of supracondylar femur fracture fixation: locked intramedullary nail vs. 95/spl deg/ angled plate","authors":"M. E. Harrow, S. M. David, R. Peindl, S. Frick, J. Kellam","doi":"10.1109/SBEC.1995.514489","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514489","url":null,"abstract":"Twelve matched pairs of fresh frozen human cadaveric femurs were tested in axial and torsional loading followed by implantation of an intramedullary nail or a 95/spl deg/ angled plate. An equal number of screws were used above the fracture, in either a grouped or dispersed configuration. Each femur was then tested with progressively more severe simulated fracture patterns. The plate with the dispersed screw configuration had the greatest torsional stiffness (p<0.0001). No significant difference was found in axial or torsional stiffness for nail or plate groups when analysing by increasing fracture severity.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127715160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A mechanical device to measure the three dimensional motion of the human jaw 测量人下巴三维运动的机械装置
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514442
V. Van Stee, J. Tortal, P.A. Williams, S. Saha
{"title":"A mechanical device to measure the three dimensional motion of the human jaw","authors":"V. Van Stee, J. Tortal, P.A. Williams, S. Saha","doi":"10.1109/SBEC.1995.514442","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514442","url":null,"abstract":"Many people suffer from temporomadibular joint (TMJ) pain and need treatment. However, the outcome of such physical therapy is often not evaluated objectively. The range of motion of the jaw could be used as an objective criterion for monitoring the effect of therapy for such patients. In this study the authors designed and manufactured such a device to measure the three dimensional motion of the jaw for human patients.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134067144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Sterilization condition of UHMWPE is measured by thermoluminescence technique 用热释光技术测定了超高分子量聚乙烯的灭菌条件
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514437
O. Hall, M. Jahan
{"title":"Sterilization condition of UHMWPE is measured by thermoluminescence technique","authors":"O. Hall, M. Jahan","doi":"10.1109/SBEC.1995.514437","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514437","url":null,"abstract":"A thermoluminescence (TL) technique, which is simple but fast and sensitive, was used as a diagnostic tool to test short-term or initial (immediately following sterilization) oxidation of UHMWPE. More than 50% radical species decayed or oxidized in the first 10 min in an oxygen environment and in 25 min in a nitrogen environment. The glow-peak temperatures 130/spl deg/C and 160/spl deg/C of the TL glow curve were also found to be associated with the sterilization conditions, nitrogen and oxygen, respectively.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115876678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of test temperature on vascular residual strain 试验温度对维管残余应变的影响
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514485
J. Vossoughi, T. Caperna
{"title":"Effect of test temperature on vascular residual strain","authors":"J. Vossoughi, T. Caperna","doi":"10.1109/SBEC.1995.514485","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514485","url":null,"abstract":"Summary form only given. In experiments dealing with mechanical characterization of biological tissues, for simplicity, the tests are usually conducted at room temperature. The validity of this practice, however, is often questioned by researchers in physiology and medicine. The purpose of the present study was to investigate the effect of test temperature on the value of the residual strain of aortic rings. Aortas from three pigs (150 kg and 6 months old) extending from the root of descending aorta to the bifurcation were used. Using a total of 240 rings from aortas of three pigs, we have found no difference in the value of residual strain at various temperatures. It is, therefore, concluded that for simplicity, residual strain measurement can be conducted at room temperature.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"49 12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123635499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Biomechanical evaluation of fixation devices for mandibular angle fractures 下颌角骨折固定装置的生物力学评价
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514426
J. Wittenberg, B. Smith, R. N. Kruse, D. P. Mukherjee
{"title":"Biomechanical evaluation of fixation devices for mandibular angle fractures","authors":"J. Wittenberg, B. Smith, R. N. Kruse, D. P. Mukherjee","doi":"10.1109/SBEC.1995.514426","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514426","url":null,"abstract":"The treatment of mandibular angle fractures is plagued with the highest postsurgical complication rate of all mandibular fractures. Multiple plating systems are available. In this study four plating variations were compared in a biomechanical in vitro study. All plating systems were noncompressive Synthes titanium plates. The 3.0 mm reconstruction plate with 6 holes, the 2 mm universal fracture plate with 6 and 8 holes and tension bands and the 6 hole universal fracture plate without tension band were compared. Measurements of gaps at the osteotomy sites showed no significant difference for the plating systems. However the vertical (inferior/superior) displacements were significantly higher for the six-hole plate without tension. The horizontal (bucca/lingual) displacement for the six-hole plate without tension had also highest displacement value. The addition of a tension band was effective to reduce these displacement values. Quantitative computed tomography scans were used to demonstrate a minimal difference in bone quality.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"297 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122008785","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The development of a masking device for tinnitus patients 耳鸣患者掩蔽装置的研制
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514415
C.E. Lopez-Reyna, R. Bagla, K.M. Lombard, J. Saunders
{"title":"The development of a masking device for tinnitus patients","authors":"C.E. Lopez-Reyna, R. Bagla, K.M. Lombard, J. Saunders","doi":"10.1109/SBEC.1995.514415","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514415","url":null,"abstract":"Over 60 million Americans suffer from \"ringing-in-the-ears\" or tinnitus. This disorder ranges from mildly annoying to debilitating, and at the moment there is no known effective medical treatment. Acoustic masking of the subjective tinnitus sound does provide a measure a relief for many patients. A narrow band masking device that is tunable and potentially portable is described in this report.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121605872","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A zinc calcium phosphorous oxide ceramic and malic acid-Ca(OH)/sub 2/-vitamin E composite for repairing bone defects 氧化锌钙磷陶瓷与苹果酸-钙(OH)/亚2/维生素E复合材料修复骨缺损
Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference Pub Date : 1995-04-07 DOI: 10.1109/SBEC.1995.514453
A. Longo, B. Mehling, P. Barre, D. Snead, A. Taylor, D. Reynolds, P. K. Bajpai
{"title":"A zinc calcium phosphorous oxide ceramic and malic acid-Ca(OH)/sub 2/-vitamin E composite for repairing bone defects","authors":"A. Longo, B. Mehling, P. Barre, D. Snead, A. Taylor, D. Reynolds, P. K. Bajpai","doi":"10.1109/SBEC.1995.514453","DOIUrl":"https://doi.org/10.1109/SBEC.1995.514453","url":null,"abstract":"The objective of this investigation was to develop a resorbable zinc calcium phosphorous ceramic oxide (ZCAP) organic acid-vitamin E composite containing an antibiotic for orthopedic and/or dental application, including nearly all cases of trauma of hard tissues. A composite consisting of 3.0 g ZCAP, 1.2 g malic acid, 0.6 g Ca(OH)/sub 2/, 9.6 mg gentamicin sulfate and 20 pl of vitamin E oil was compressed in a 5/16\" die into 0.1 g pellets at a load of 2000 lbs in a hydraulic press. The right femur of experimental animals was accessed by routine surgical procedures. A mid-diaphyseal fracture was created under direct vision using a surgical bone saw. A 0.62 threaded K-wire was inserted into the intramedullary canal and retrograded through the knee using a drill. The implant was placed between the two ends of the fracture and the K-wire antegraded through the pellet into the proximal end of the femur and tested to assure good fixation. The K-wire protruding from the bone was cut flush with the end of the bone using wire cutters. The surgical site was closed using routine surgical procedures. Post surgery, each rat showed normal movement during the ten week experimental period. Gross morphological examination of euthanized animals showed filling of the defect. Radiographic examination of the bones showed resorption of the composite, evidence of bone healing and cancellous bone ingrowth. However, the new bone ingrowth appeared less dense than the cortical bone on either side of the defect. The data collected to date suggest that ZCAP composites can be used as osteoconductive fillers between two fractured ends of a bone.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127240743","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信