{"title":"Sterilization condition of UHMWPE is measured by thermoluminescence technique","authors":"O. Hall, M. Jahan","doi":"10.1109/SBEC.1995.514437","DOIUrl":null,"url":null,"abstract":"A thermoluminescence (TL) technique, which is simple but fast and sensitive, was used as a diagnostic tool to test short-term or initial (immediately following sterilization) oxidation of UHMWPE. More than 50% radical species decayed or oxidized in the first 10 min in an oxygen environment and in 25 min in a nitrogen environment. The glow-peak temperatures 130/spl deg/C and 160/spl deg/C of the TL glow curve were also found to be associated with the sterilization conditions, nitrogen and oxygen, respectively.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBEC.1995.514437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A thermoluminescence (TL) technique, which is simple but fast and sensitive, was used as a diagnostic tool to test short-term or initial (immediately following sterilization) oxidation of UHMWPE. More than 50% radical species decayed or oxidized in the first 10 min in an oxygen environment and in 25 min in a nitrogen environment. The glow-peak temperatures 130/spl deg/C and 160/spl deg/C of the TL glow curve were also found to be associated with the sterilization conditions, nitrogen and oxygen, respectively.
用热释光技术测定了超高分子量聚乙烯的灭菌条件
热释光(TL)技术是一种简单、快速、灵敏的诊断工具,用于检测UHMWPE的短期或初始(灭菌后立即)氧化。超过50%的自由基在氧气环境中的前10分钟和在氮气环境中的前25分钟腐烂或氧化。TL发光曲线的发光峰温度分别为130/spl°C和160/spl°C,与灭菌条件、氮气和氧气有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信