{"title":"A micromechanical relay with a thermally-driven mercury micro-drop","authors":"J. Simon, S. Saffer, C. Kim","doi":"10.1109/MEMSYS.1996.494035","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.494035","url":null,"abstract":"We present a mercury-contact micro-mechanical relay. While microrelays have been introduced to MEMS on several occasions, all are based on solid contacts, leaving the same contact problems faced by macroscale mechanical relays. The goal of our device is to use mercury to eliminate surface degradation, signal bounce, and high resistance at contacts common in solid contact devices. Descriptions of the design and fabrication of a micromechanical relay with a thermally-driven 25 /spl mu/m mercury micro-drop are presented, including the technique for formation of mercury droplets, as well as some data on the switching performance of the relay. Video demonstration of the actuation sequence will be presented.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116672009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new fabrication method for microactuators with piezoelectric thin film using precision cutting technique","authors":"Y. Yamagata, S. Mihara, N. Nishioki, T. Higuchi","doi":"10.1109/MEMSYS.1996.493999","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.493999","url":null,"abstract":"A new fabrication method for microactuators and microstructures is presented. It is based on a precision cutting technique and hydrothermal method to make piezoelectric thin film. It is generally considered that the cutting technique is not suitable for microparts fabrication because the cutting force is too large compared to the size of the structure. The authors have used a four axis ultra precision machine tool to prevent the problem of cutting force and were successful in fabricating three dimensional microstructures. Even a 10 /spl mu/m shaft or 100 /spl mu/m screw were possible to fabricate. On the surface of the microstructures, piezoelectric thin film is plated through hydrothermal method. Electrode pattern is produced through direct laser beam ablation. Fabrication examples of each process are presented and an application to a micro vibration gyro is proposed.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121217554","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power characteristics of 3-D operated microturbines for minimally invasive therapy","authors":"U. Wallrabe, J. Mohr, I. Tesari, K. Wulff","doi":"10.1109/MEMSYS.1996.494026","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.494026","url":null,"abstract":"Radial microturbines which can be integrated onto minimally invasive surgical tools are presented. With view to medical compatibility the turbines are operated using water. The fluid is delivered in normal direction to the turbine rotor which is realised by a hybrid set-up of assembled turbine components. The required microcomponents are fabricated using LIGA technology and mechanical microengineering resulting in multi-stepped microstructures, if necessary. The power characteristics of the turbines have been evaluated by macromodels with respect to hydrodynamic similarity laws. Thus, a design with a maximum power output is found. The turbines provide high numbers of revolutions making them particularly useful for milling and drilling operations.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"161 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115997295","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Ando, J. Ino, K. Ozaki, Y. Ishikawa, T. Kitahara
{"title":"Friction and pull-off force on silicon surface modified by FIB","authors":"Y. Ando, J. Ino, K. Ozaki, Y. Ishikawa, T. Kitahara","doi":"10.1109/MEMSYS.1996.494006","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.494006","url":null,"abstract":"The friction and adhesion forces were measured for silicon surfaces that had various patterns having cyclic asperity. The patterns were created by using a focused ion beam (FIB) to mill ditches and to deposit platinum mounds. To study the effect of cyclic asperity on the forces, the friction and pull-off forces were measured between the pattern and a flat, square scanning probe (0.7/spl times/0.7 /spl mu/m/sup 2/) of an atomic force microscope (AFM). Both the friction and pull-off forces decreased as the asperity increased (i.e., as the ditch depth or mound height increased). The decrease was greater for the cyclic ditches than for the cyclic mounds. The friction force was proportional to the pull-off force, which indicates the importance of reducing the adhesion force when devising lubrication methods for micromachines and micro-electro mechanical systems (MEMS).","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116125924","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chang-Yeol Lee, Yoonhyuk Kim, Yong-Gie Choi, Young‐Ho Cho, K. Lee, B. Kwak
{"title":"High-density silicon microprobe arrays for LCD pixel inspection","authors":"Chang-Yeol Lee, Yoonhyuk Kim, Yong-Gie Choi, Young‐Ho Cho, K. Lee, B. Kwak","doi":"10.1109/MEMSYS.1996.494020","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.494020","url":null,"abstract":"A novel structure and fabrication methods of high-density silicon microprobes have been developed for use in the pixel-wise inspection of flat-panel screens. The microprobe array consists of 101 parallel cantilever-beam springs, fabricated by an anisotropic etching of [110] silicon wafers. Each microbeam contains a hemispheric gold probe-tip for one-to-one electrical contact with high-density flat-panel electrodes, metal lines for pixel-wise electrical signal drive, and self-diagnostic structures for beam breakage detection. The dimensions of the microprobe array have been decided to meet a series of design constraints, including geometric and strength requirements, microfabrication constraints and the admissible ranges of contact forces, obtained from preliminary experiments. An integrated fabrication process has been developed based on surface-micromachining, electroplating, and bulk-micromachining processes with an etch-rate based corner compensation technique. The fabricated microprobe array has been applied to the probing of high-density electrodes on the 640/spl times/480 STN-LCD panel, resulting in stable electrical contacts for an applied load of 2g/sub f/ per microbeam.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122391470","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electroplated thick CoNiMnP permanent magnet arrays for micromachined magnetic device applications","authors":"T.M. Linkopoulos, Wenjin Zhang, G.H. Ahn","doi":"10.1109/MEMSYS.1996.493833","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.493833","url":null,"abstract":"Electroplated thick CoNiMnP permanent magnet arrays for micromachined magnetic device applications have been designed, fabricated, and tested. The electroplated arrays contain 5000 magnets of 40 /spl mu/m/spl times/40 /spl mu/m/spl times/50 /spl mu/m in a cubic shape on the silicon membrane of 4.6 mm/spl times/4.6 mm /spl times/20 /spl mu/m, where the magnets have shown a fairly high magnetic vertical coercivity of 600 Oe, a retentivity of 0.2-0.3 Teslas, and a maximum energy density of 10 kJ/m/sup 3/. Using the electroplated magnet array, a proto-type bi-directional vertical microactuator on silicon membrane has been realized with integrated spiral coils. The magnet arrays realized in this work allow a low power consumption, a flexible bi-directional actuation, as well as a favorable CMOS compatibility.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121899039","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Surface-micromachined electrostatic-comb driven scanning micromirrors for barcode scanners","authors":"M. Kiang, O. Solgaard, R. Muller, K. Y. Lau","doi":"10.1109/MEMSYS.1996.493852","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.493852","url":null,"abstract":"This paper describes the design and fabrication of micromachined resonant scanners that have large scan angles at fast scan speeds. Driven by an electrostatic comb motor, these 200 /spl mu/m by 250 /spl mu/m scanning-micromirrors can scan about 12/spl deg/ (optical) at the resonance frequency of 3 kHz with a sinusoidal voltage input of 20 V in amplitude. Fabricated with a four-poly-layer silicon-surface-micromachining process, these resonant scanners are compact, extremely light in weight, and potentially very low in cost. The power consumption is also minimal since the capacitive motor draws very little current. We have demonstrated the scanner as a laser-beam deflector in a barcode reader, a potentially important application that has a growing popularity in many industries.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121436913","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A microactuator system for the study and control of screech in high speed jets","authors":"Chunchieh Huang, J. Papp, K. Najafi, H. Nagib","doi":"10.1109/MEMSYS.1996.493823","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.493823","url":null,"abstract":"The development of an electrostatic microactuator system for closed-loop control of screech in a high-speed jet flow system is presented in this paper. The electrostatic actuators have been fabricated using a bulk-silicon dissolved-wafer process, and are more than 10 /spl mu/m in thickness needed for large stiffness in z-direction. The actuators can resonate at a frequency of about 5 kHz, consistent with the \"screech\" frequency, and an amplitude of 70 /spl mu/m peak to peak using 20 V dc and 20 V ac drive voltage. The system consists of several of these actuators mounted at the exit lip of a high-speed jet flow system and has been shown to provide disturbances in the jet flow measured downstream from the jet nozzle. Closed-loop control strategies and experiments are underway to demonstrate control of screech.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133290936","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Kahn, S. Stemmer, K. Nandakumar, A. Heuer, R. Mullen, R. Ballarini, M. Huff
{"title":"Mechanical properties of thick, surface micromachined polysilicon films","authors":"H. Kahn, S. Stemmer, K. Nandakumar, A. Heuer, R. Mullen, R. Ballarini, M. Huff","doi":"10.1109/MEMSYS.1996.494005","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.494005","url":null,"abstract":"Polycrystalline silicon is the most widely used structural material for surface micromachined microelectromechanical systems (MEMS). There are many advantages to using thick polysilicon films; however, due to process equipment limitations, these devices are typically fabricated from polysilicon films less than 3 /spl mu/m thick. In this work, microelectromechanical test structures were designed and processed from thick (up to 10 /spl mu/m) undoped and in situ boron-doped polysilicon films. The elastic moduli of the doped films were 150/spl plusmn/30 GPa, and appeared to be independent of film thickness. The thermal oxidation of the polysilicon induced a compressive stress into the top surface of the films, which was detected as a residual stress in the polysilicon after the device fabrication was complete. The average nominal fracture toughness of the polysilicon was 2.3/spl plusmn/0.1 MPa /spl radic/m.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"114 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133815434","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
F. Jiang, Y. Tai, B. Gupta, R. Goodman, S. Tung, Jin-Biao Huang, Chih-Ming Ho
{"title":"A surface-micromachined shear stress imager","authors":"F. Jiang, Y. Tai, B. Gupta, R. Goodman, S. Tung, Jin-Biao Huang, Chih-Ming Ho","doi":"10.1109/MEMSYS.1996.493838","DOIUrl":"https://doi.org/10.1109/MEMSYS.1996.493838","url":null,"abstract":"A new MEMS shear stress sensor imager has been developed and its capability of imaging surface shear stress distribution has been demonstrated. The imager consists of multi-rows of vacuum-insulated shear stress sensors with a 300 /spl mu/m pitch. This small spacing allows it to detect surface flow patterns that could not be directly measured before. The high frequency response (30 kHz) of the sensor under constant temperature bias mode also allows it to be used in high Reynolds number turbulent flow studies. The measurement results in a fully developed turbulent flow agree well with the numerical and experimental results previously published.","PeriodicalId":328680,"journal":{"name":"Proceedings of Ninth International Workshop on Micro Electromechanical Systems","volume":"163 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128346318","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}