C. Hasselfield, P. Wilson, L. Penner, M. Lau, A. Gole
{"title":"An automated method for least cost distribution planning","authors":"C. Hasselfield, P. Wilson, L. Penner, M. Lau, A. Gole","doi":"10.1109/WESCAN.1991.160543","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160543","url":null,"abstract":"The authors describe a method of planning changes to a distribution system to meet load projections by minimizing the cost of these changes while ensuring the system meets required constraints. A computer program uses the method of simulated annealing to evaluate various configurations and to derive the optimal solution. The program evaluates options normally considered in a distribution planning study, such as reconductoring sections of feeders and switching sections of one feeder to another feeder. At each step of the optimization process, the program performs a load flow analysis to find the total losses and to check constraints. The objective function to be optimized is the cost of the changes added to the cost of the losses. The program has been used for several studies, including an existing 7.2 kV distribution system, and has provided good results.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114618118","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Active solar space heating in a Canadian prairie farmhouse","authors":"W. Stewart, N. Stewart","doi":"10.1109/WESCAN.1991.160538","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160538","url":null,"abstract":"The operation of a solar air heating system in a Canadian prairie farm home is described. It is shown that the system provides significant heat in the coldest months, shortens the supplementary heating season, and provides an extra measure of reliability and comfort compared to conventional heating methods. The system employs 26.5 m/sup 2/ of heater on a 250 m/sup 2/ house, uses air for the transfer fluid, rock for heat storage, and a gravity distribution system. Results show that this type of solar air heater can provide a significant amount of the space heating in an environmentally effective manner.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122993114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Security testing of high impedance fault detectors","authors":"A. Sultan, G. Swift","doi":"10.1109/WESCAN.1991.160545","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160545","url":null,"abstract":"The security of high-impedance fault (HIF) relays is examined. Waveforms of HIFs as well as loads that behave to appear like HIFs were collected and processed. The detection parameters used in a number of present HIF detection algorithms were extracted and compared to test the algorithms' ability to discriminate between faults and fault-like loads. It was found that there are loads that imitate HIFs, and that the present algorithms lack the security required under these load conditions. The high-impedance fault-like loads considered were: an arc welding machine; a personal computer; and a fluorescent light. It was found that arc welders can easily imitate HIF conditions, and that the tested algorithms showed insecurity when tested with an arc welder load.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"103 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114604987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"i/sup 2/F-Integrated Interface Facility","authors":"F. W. Tunison, G. Urquhart","doi":"10.1109/WESCAN.1991.160554","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160554","url":null,"abstract":"i/sup 2/F (Integrated Interface Facility) is a personal computer-based program which utilizes a scripting language to support console automation. The authors examine the nature of i/sup 2/F, where i/sup 2/F is best used, the design principles of i/sup 2/F, and the three versions of i/sup 2/F.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"38 6","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120889138","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A speech recognition system using a neural network model for vocal shaping","authors":"C. Love, W. Kinsner","doi":"10.1109/WESCAN.1991.160549","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160549","url":null,"abstract":"An automatic, isolated, limited vocabulary, multilevel speech recognition system is presented. The system uses a standard backpropagation neural network as the recognizer and linear predictive coding coefficients as the recognition feature. The recognition of an utterance involves the identity (class) and version (quality level). Multilevel classification involves using up to five discrete nonlinear levels that correspond to human assessment. The system software was developed using both Microsoft C and Think C. The result of the multilevel test using a vowel subset achieved 61.8% recognition, and it achieved an average classification of good. The consonant test achieved recognition of 46.5% and 48% for the vowels /a/ and /e/, respectively. The system is intended to be used as a vocal shaping tool by autistic individuals, thus requiring a multilevel recognition scheme.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125328385","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. McLaren, A. Gole, J. R. Lucas, I. Macbeath, G. Irwin, C. Bohn
{"title":"A workstation environment for assessing relay performance","authors":"P. McLaren, A. Gole, J. R. Lucas, I. Macbeath, G. Irwin, C. Bohn","doi":"10.1109/WESCAN.1991.160513","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160513","url":null,"abstract":"The authors describe an offline simulation facility for assessing the transient performance of relays. The facility is based on a user-friendly workstation environment whereby input and output information is presented in graphical form, making it easy for the nonexpert to use sophisticated simulation tools to solve problems relevant to choosing and setting relays. This greatly reduces the turnaround time in making design decisions and enhances appreciation of the capability and limitations of the elements in a protection system.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124167577","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. McLaren, R. Kuffel, R. Wierckx, J. Giesbrecht, L. Arendt
{"title":"A digital TNA for testing relays","authors":"P. McLaren, R. Kuffel, R. Wierckx, J. Giesbrecht, L. Arendt","doi":"10.1109/WESCAN.1991.160518","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160518","url":null,"abstract":"The authors describe the design and performance of a digital transient network analyzer (DTNA) for testing relays. The DTNA uses a parallel processing architecture to run power system simulations in real time with a time setup of 50-100 mu s. Relays can be fed with the appropriate signals from the DTNA, and the output from the relay trip circuit can be fed back into the simulation. Examples are given of tests on a commercial distance relay.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123799612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A thin route digital radio","authors":"S. Kumar, L.E. Fisher, T. Truman","doi":"10.1109/WESCAN.1991.160568","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160568","url":null,"abstract":"An eight-channel VHF digital radio is described. The radio was designed to provide service to remote communities located 100 km or more from the nearest node of a microwave LOS (line-of-sight) network. Some of the novel design features of the radio are briefly discussed. The performance results of a field trial in northern Saskatchewan are presented.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134116439","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Adaptive relaying for protecting a distribution system-a feasibility study","authors":"B. Chattopadhyay, M. S. Sachdev, T. S. Sidhu","doi":"10.1109/WESCAN.1991.160514","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160514","url":null,"abstract":"The feasibility of an adaptive relaying system for a distribution network is examined. A reduced version of the City of Saskatoon distribution network has been selected for this study. Overcurrent and directional overcurrent relays are used to protect the system. The scope of the work includes changing relay settings and relay pick-up currents in an online mode as operating conditions of the system change. The system changes considered are the loads and generation level changes and line and transformer outages over a period of several days. Relay coordination and communication software which are essential for implementing an adaptive relaying system are discussed. A laboratory model for an adaptive relaying system is presented. It is shown that by using microprocessor-based relays and appropriate software, as well as communication aids, an adaptive relaying concept can be implemented.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117336135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Oprişan, F. Filippelli, I. Clark, R. Billinton
{"title":"A reliability data system for the reporting of forced outages of distribution equipment","authors":"M. Oprişan, F. Filippelli, I. Clark, R. Billinton","doi":"10.1109/WESCAN.1991.160559","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160559","url":null,"abstract":"A system for reporting forced outages of distribution systems is described. Seven major component categories are used for this purpose, each of which is further divided into classes. This classification system provides the means for recording the forced outages of major components by type. Each forced outage is ascribed a primary cause and, in addition, each major component is assigned a list of subcomponents in order to identify which part of the major component was the cause of the outage or was damaged as a result. From these data, forced outage statistics can be calculated and an appraisal of the reliability of each type of major component can be made.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"122 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123432688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}