{"title":"A neural network mapper for stochastic code book parameter encoding in code-excited linear predictive speech processing","authors":"A. Indrayanto, A. Langi, W. Kinsner","doi":"10.1109/WESCAN.1991.160550","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160550","url":null,"abstract":"The authors present a novel method of stochastic code book (SCB) searching for code excited linear predictive (CELP) coding by implementing the counterpropagation neural network model. The high performance of CELP is achieved at the expense of very high computational power required to find the SCB parameters. The counterpropagation neural network model is used to replace the exhaustive serial searching process by an open-loop, less computationally demanding code book parameters encoding. A scheme to embed the neural network model into the original CELP coding is presented. The scheme is equivalent to a standard CELP with a 512 word SCB. The system performance is analyzed and compared with the present closed-loop parameter searching method.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116157162","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A digital multiplexed fiber optic transmission system for analog audio signals","authors":"T. Lee, K. Runtz, E. H. Hara","doi":"10.1109/WESCAN.1991.160537","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160537","url":null,"abstract":"The distribution of multiple high-fidelity audio signals over distances up to several kilometers has potential applications in commercial and institutional settings. A fiber-optic system for six channels is described. The system employs time division multiplexing to transmit six audio signals over a single optical fiber. The transmission circuitry is simplified by the use of a second fiber to transmit the system clock frequency. The system is designed for a frequency response of 100 Hz-20 kHz +or-1 dB over a minimum range of 1 km. A prototype of the design was assembled and preliminary tests indicated satisfactory performance.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"194 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122850499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analytical investigation of electrical transient phenomena in the Island Falls-Points North 138 kV line and substations","authors":"D. Ruiu, L.B. Rifaat","doi":"10.1109/WESCAN.1991.160531","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160531","url":null,"abstract":"SaskPower staff carried out, at the planning stage, several technical studies for the 138 kV Island Falls to Points North line and the substations connected to it. Electromagnetic Transient Program (EMTP) simulation runs provided the basic information required for the analytical investigation of the various electric transient phenomena which may appear in this 138 kV line and substations SaskPower planners used the conclusions obtained from this analysis to finalize the specifications for the electrical apparatus and make recommendations concerning the allowable operating procedures.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114461904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A digital subscriber loop carrier system for providing private line service on multi-party lines","authors":"W.J. Misskey, K.J. Runtz, Y. Liaw, S. Abozgaia","doi":"10.1109/WESCAN.1991.160533","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160533","url":null,"abstract":"To improve multiparty telephone services, a four-channel digital subscriber loop carrier system is proposed. Adaptive differential pulse code modulation bipolar 6-zero substitution line coding, and time-compression multiplexing of speech packets under microprocessor control are novel features of the proposed system. It is believed the design for a digital subscriber loop carrier system outlined will meet the requirements for providing private line service on multiparty lines. The cost of such a system is expected to be less than that required for reinforcement with metallic cables, while providing a comparable level of service.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114764968","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
W.M. Kotyk, T. G. Kirk, N. Klassen, J. N. Wilson, E. Jan
{"title":"Control system for combine harvesters","authors":"W.M. Kotyk, T. G. Kirk, N. Klassen, J. N. Wilson, E. Jan","doi":"10.1109/WESCAN.1991.160528","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160528","url":null,"abstract":"The design of a combine harvester system for controlling feedrate, sieve airflow, and cylinder speed is presented. Field tests show that feedrate control can lead to increased harvesting (productivity) rates. This feature, in combination with cylinder speed control, also reduces the risk of plugging under normal conditions. Airflow control on the sieves should contribute to increased separation efficiency and reduced loose grain loss. Cylinder speed control through an engine throttle boost compensates for sudden surges in feedrate, resulting in reduced cylinder and separation losses. This indicates that the throttle boost and simultaneous reduction in ground speed, as a result of a momentum interchange, is very effective in maintaining cylinder speed for sudden increases in feedrate.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130277559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Protection application considerations for northern transmission","authors":"L. Yee","doi":"10.1109/WESCAN.1991.160532","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160532","url":null,"abstract":"Two transmission systems in northern Saskatchewan, which have weak sources, long lines, high ground impedances, system harmonics and possible machine self-excitation, are discussed. These conditions create problems with protection applications. The weak nature of the system, coupled with long lines, makes it difficult to set the relays sensitive enough to detect faults. On the other hand, the expected harmonics and system self-excitation problems require the relays to be set less sensitively. These two points are conflicting requirements. The author discusses these problems, presents the solutions chosen, and provides a protection performance analysis.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132961019","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. J. Fleming, V. Sharma, L. Niekamp, William Borbely
{"title":"Harmonic analysis of a reduced SaskPower transmission network using an iterative approach","authors":"R. J. Fleming, V. Sharma, L. Niekamp, William Borbely","doi":"10.1109/WESCAN.1991.160562","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160562","url":null,"abstract":"Studies concerned with the harmonic voltage profile calculation of an electric power system are reported. An iterative method is used for computing the harmonic voltage profile. The method is based on frequency-domain analysis in conjunction with fundamental load flow computations. The advantage of the iterative method is that it obtains a realistic harmonic voltage profile without the need for field measurements. Such a method is helpful in the planning of a power system or extension of an existing power system. The model of transmission lines used specifically lends itself to the determination of voltage profile on a long transmission line. The important concepts of conventional reactive power and distortion power are incorporated in order to determine interaction between the power system and harmonic generating sources. A reduced power transmission network of SaskPower is analyzed to illustrate the use of the algorithm.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"412 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115938179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On partial neural-net decoding with retransmissions for data communications","authors":"Q. Yang, Q. Wang, V. Bhargava","doi":"10.1109/WESCAN.1991.160567","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160567","url":null,"abstract":"The authors discuss basic issues on partial decoding of linear block codes with retransmissions by recently developed neural network technology. In particular, the basic structure of a neural-net decoder is defined based on syndrome decoding methods. Partial decoding by the pocket algorithm and the random sampling algorithm is proposed, and its throughput performance is examined. The complexity issues of using feedforward neural networks for decoding programs are also addressed. Neural-net decoding could be a good alternative for providing an error control mechanism for data communications.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129330359","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Island Falls to Points North transmission system planning studies","authors":"G. Bélanger","doi":"10.1109/WESCAN.1991.160530","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160530","url":null,"abstract":"The author describes the planning studies conducted in the development of a transmission line proposal to supply power to several remote mines located in northern Saskatchewan. Because the required length of transmission line will be extensive, with large induction motor loads concentrated near the line end, the potential exists for extremes in voltage, both in steady state and during contingencies. The studies discussed principally address these possible voltage control problems. A 138 kV, uncompensated Island-Falls-to-Points-North (IF-PN) transmission line, with 477 kcmil conductor, was recommended for this system. The steady-state studies conducted show that series or shunt compensation would be necessary to supply the peak system load condition for 115 kV operation. Avoiding the need for series compensation on the 138 kV system will allow more capacity for upgrading the system in the future. Even though an additional transformation would be required for 138 kV operation, the reduced losses associated with 138 kV operation would represent a cost advantage compared with a 115 kV compensated system. Dynamic simulation studies confirmed that a 138 kV uncompensated IF-PN transmission system would satisfy the requirements for fault recovery, motor starting, and overvoltage control.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131835224","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Protecting a distributed data acquisition system from lightning","authors":"J.R. Saltvold","doi":"10.1109/WESCAN.1991.160519","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160519","url":null,"abstract":"In 1983 AECL Research installed a hydrogeological monitoring system at its underground research laboratory (URL) site to record water levels in about 40 boreholes spread over an area 1.5 km by 2.5 km. A major concern in designing this system was to make it resistant to damage from lightning. Other systems, installed over much smaller areas, were frequently damaged by lightning, even though pickup from the power line was often eliminated by using battery or generator power. The system described is line-powered and achieves resistance to lightning through the following measures: surge protectors, filters and ultraisolation transformers installed on connections to the power line, and surge protectors installed at each end of the lines transmitting analog and digital signals over long distances. These measures have not completely eliminated damage from lightning, but have kept it within acceptable limits and are probably all that can be done with existing technology.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120983462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}