{"title":"Solid state single phase to three phase converter","authors":"S. Olsen","doi":"10.1109/WESCAN.1991.160544","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160544","url":null,"abstract":"The development of the 5 hp prototype solid state phase converter has been completed. The converter will fill a need for motor drives which require more control than the present phase converters can provide but do not require a full-blown variable frequency drive. While a variable frequency drive can operate a three phase motor from a single phase supply, it does not typically provide power factor correction as the solid state phase converter does. The technology developed is capable of handling a power level equal to the entire service capacity of a standard rural feed.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"108 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115670476","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design of a microprocessor-based overcurrent relay","authors":"T. S. Sidhu, M. S. Sachdev, H. C. Wood","doi":"10.1109/WESCAN.1991.160517","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160517","url":null,"abstract":"The authors describe the design of a microprocessor-based overcurrent relay that is suitable for protecting distribution and subtransmission networks. A modified technique for modeling the time-current characteristics is described. The proposed design is implemented using a Texas Instruments TMS320C25 digital signal processor. Some details of the hardware and software of the relay are presented. A digital overcurrent relay is also described. Test results indicate that the overcurrent relay accurately emulates the desired time-current characteristics.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126695165","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"FT/sup 2/D: fiber-to-the-desk","authors":"P. Kong, T. Lee, E. H. Hara","doi":"10.1109/WESCAN.1991.160536","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160536","url":null,"abstract":"Attention is given to the FT/sup 2/D unit, a full-duplex fiber optic multiplexer-demultiplexer that can be placed on a desk top. It has an aggregate digital transmission capacity of 100 Mb/s consisting of ten 10 Mb/s full duplex channels. These channels are submultiplexed into eight 1.25 Mb/s channels, providing a total of 80 full-duplex data channels. These data channels can be allocated electronically to meet a given telecommunication requirement. To provide flexibility in meeting a wide range of telecommunication needs, the unit has one card slot for the fiber-optic multiplexer-demultiplexer card and two card slots for interface cards. The two interface card slots offer a flexible approach to meet specific needs because a wide range of interface cards supporting various telecommunication needs, such as analog telephone, RS-232C, and Ethernet local area networks, are offered.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"28 8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123600386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Enhancing rural Saskatchewan health care through telecommunications and information management","authors":"P. Kindred, D. Harley","doi":"10.1109/WESCAN.1991.160535","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160535","url":null,"abstract":"It is suggested that telecommunication and information management technology can play a catalytic role in the rebirth of rural Saskatchewan health care. Three available technologies that may provide solutions to the problems that rural Saskatchewan health care is experiencing are discussed. SmartCard technology can provide province-wide access to patient records. Distance education via satellite, microwave, and fiber-optic links can provide continuing education for health care professionals and health work shops for the public. Teleradiology for distance diagnostics can provide specialist services to rural and remote locations.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121545671","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Athabasca Transmission System voltage control studies","authors":"A. C. Thomson, D. Cotcher","doi":"10.1109/WESCAN.1991.160529","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160529","url":null,"abstract":"The Athabasca Transmission System was first energized on October 20, 1988. Bus voltage measurements provided by remote telemetry during the energization process showed values for the fundamental frequency voltages that were within 1% of predicted values. Voltage recordings provided by transient fault data recorders indicate that the harmonic overvoltages that occurred on system energization compared well with the EMTP (Electromagnetic Transients Program) simulations. For full load rejections that have occurred on the system since its commissioning, the automatic voltage regulators (AVRs) have successfully controlled the voltages.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"84 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134505480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Guang-You Tu, O. Malik, Peichun Liu, Zhengliang Bu
{"title":"8096 single-chip-microcomputer-based system for application in digital control and protection of power systems","authors":"Guang-You Tu, O. Malik, Peichun Liu, Zhengliang Bu","doi":"10.1109/WESCAN.1991.160515","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160515","url":null,"abstract":"An Intel 8096 single-chip-microcomputer (SCMC)-based system using a hierarchical structure has been developed. It consists of a master unit and slave units realized by the 8096 SCMCs. The master unit performs the primary function, and the slave units perform ancillary functions such as sampling and data preprocessing. It can be employed for different industrial applications with only a small change in the bus interconnections and the associated application software. The system developed is simple in logic structure, low in cost (which is very important in developing countries), and high in reliability. Basic principles, details of the logic structure, 8096-SCMC implementation of the developed system, and two applications in digital control and protection of power systems are described.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128229090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Using i/sup 2/F at the help desk (integrated interface facility)","authors":"F.W. Tunison, R. Coller","doi":"10.1109/WESCAN.1991.160555","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160555","url":null,"abstract":"The authors describe the evolution of i/sup 2/F (Integrated Interface Facility) at the Westbridge Computer Corporation help desk. Past events that explain the changes that have occurred in the help desk from its inception to the present are examined. This is followed by a discussion of the current operations and development projects. The authors conclude with a view of what the help desk at Westbridge in the future might be, and thus provide with a target for planning, configuration, and staff requirements, and a justification for meeting market needs.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123484227","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Device for the integration of television and telephone control via hand held infrared remote","authors":"P. D. King","doi":"10.1109/WESCAN.1991.160566","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160566","url":null,"abstract":"The author describes a device built for SaskTel's Superman 1 Trial. The objective was to provide the look and feel of an integrated two-way broadband network. The device described integrates control of telephone and television systems at the hand-held remote, providing the user with interactive video-on-demand.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124573791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An approach to benchmarking storage reclamation strategies","authors":"J. Katzberg, P. Katzberg","doi":"10.1109/WESCAN.1991.160552","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160552","url":null,"abstract":"A research program to gain experimental data to test the various conjectures and theories concerning the performance of storage reclamation strategies in a virtual memory environment is reported. A modular Lisp interpreter was designed in which various list storage and reclamation strategies could be implemented and evaluated. This Lisp interpreter is implemented in Turbo Pascal and runs under Microsoft DOS. It includes a virtual memory system. The Lisp interpreter is described along with the test programs and measurement strategies used for evaluating storage reclamation (termed garbage collection) performance in a virtual memory environment. Preliminary results are presented.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"550 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123243704","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simulation of power system dynamics by the singular perturbation technique","authors":"Mao Chengxiong, Fan Jun, O. Malik","doi":"10.1109/WESCAN.1991.160546","DOIUrl":"https://doi.org/10.1109/WESCAN.1991.160546","url":null,"abstract":"Application of the principle of singular perturbation to the simulation of electric power system dynamics is studied. The proposed method is used in place of Newton's method to simultaneously solve the difference equations and algebraic equations in implicit integration techniques. It is much faster than Newton's method per step when the step is the proper length. This method also has high accuracy.<<ETX>>","PeriodicalId":327448,"journal":{"name":"[Proceedings] WESCANEX '91","volume":"136 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1991-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123417823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}