1988 Conference on Precision Electromagnetic Measurements最新文献

筛选
英文 中文
In search of the best clock 寻找最好的时钟
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671187
D. Allan, M. Weiss, T. K. Peppler
{"title":"In search of the best clock","authors":"D. Allan, M. Weiss, T. K. Peppler","doi":"10.1109/CPEM.1988.671187","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671187","url":null,"abstract":"Because of the increased need for better clock performance than is currently available, this paper addresses some fundamental questions regarding clock metrology. Heretofore, most work has focussed on improving the clocks to meet the increased need. Though this is fundamental and will be addressed in the paper, we will also show that significant gains are available through the algoritbms which process the clock readings and through international comparisons now available via satellite. Proper algorithms for processing seem to be more important than the proportionate attention generally given them. In fact, to date, the only way we have been able to investigate some of the long-term performance aspects of the millisecond pulsar, ESR 1937+21, is by using such optimization algorithms. Since there are indications in the pulsar data of variations which could be explained as arising from the influence of gravity waves, these long-term stability studies take on a new importance. Years of study will probably be necessary to confirm these initial indications, but clearly improved long-term stability of earth-bound clock systems would significantly assist this study.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131665558","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 27
NBS Determination of the Fine-Structure Constant, and of the Quantized Hall Resistance and Josephson Frequency to Voltage Quotient in Si Units 精细结构常数的NBS测定,以及量子化霍尔电阻和约瑟夫森频率对Si单位电压商的影响
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671331
M. E. Cage, R. Dziuba, R. Elmquist, G. Jones, P. T. Olsen, W. Phillips, J. Q. Shields, R. Steiner, B. Taylor, E. Williams
{"title":"NBS Determination of the Fine-Structure Constant, and of the Quantized Hall Resistance and Josephson Frequency to Voltage Quotient in Si Units","authors":"M. E. Cage, R. Dziuba, R. Elmquist, G. Jones, P. T. Olsen, W. Phillips, J. Q. Shields, R. Steiner, B. Taylor, E. Williams","doi":"10.1109/CPEM.1988.671331","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671331","url":null,"abstract":"Results from NBS experiments to realize the ohm and the watt, to determine the proton gyromagnetic ratio and the time dependence of the NBS ohm using the quantum Hall effect, and to maintain the NBS volt using the Josephson effect, are appropriately combined to obtain a highly accurate value of the fine-structure constant and of the quantized Hall resistance in SI units, and accurate values in SI units of the Josephson frequency to voltage quotient, Planck constant, and elementary charge.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130386386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
A Current-Dividing-Type High Stable DC Current Transformer Using a Magnetic Modulator 一种采用磁调制器的分流型高稳定直流电流互感器
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671231
M. Abe, J. Nakazoe
{"title":"A Current-Dividing-Type High Stable DC Current Transformer Using a Magnetic Modulator","authors":"M. Abe, J. Nakazoe","doi":"10.1109/CPEM.1988.671231","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671231","url":null,"abstract":"A high stable(lppm) large dc current transformer is described. It is constructed using a current dividing network by shunt resistors and two magnetic-modulator-type ampere-turn comparators. The transform ratio of the transformer is independent of the current ratio in the shunt resistors.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129990052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measurement Of The Complex Permittivity Of Microwave Materials With A Submillimeter Waveguide Four-Port Reflectometer 用亚毫米波波导四端口反射计测量微波材料的复介电常数
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671221
U. Stumper
{"title":"Measurement Of The Complex Permittivity Of Microwave Materials With A Submillimeter Waveguide Four-Port Reflectometer","authors":"U. Stumper","doi":"10.1109/CPEM.1988.671221","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671221","url":null,"abstract":"A new four-port reflectometer for the determination of the complex relative permittivity of microwave materials at submillimeter wavelengths is described. Measurement results obtained with various low-loss solids at frequencies of about 380 GHz agree well with data taken from the literature or obtained as results of an international comparison measurement exercise.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131172477","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Controlling And Data Acquisition System For The Reference Diffuse Reflectance Spectrophotometer Based On The IBM-PC/XT Computer 基于IBM-PC/XT计算机的基准漫反射分光光度计控制与数据采集系统
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671300
Deming Zhu, M. Wu, J. Hsia
{"title":"A Controlling And Data Acquisition System For The Reference Diffuse Reflectance Spectrophotometer Based On The IBM-PC/XT Computer","authors":"Deming Zhu, M. Wu, J. Hsia","doi":"10.1109/CPEM.1988.671300","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671300","url":null,"abstract":"A System has been designed for controlling, acquiring and storing the photoelectric signals for the reference reflectance spectrophotometer in the division of radiometric physics at the NBS. Based on the IBM-PC/XT computer system, the GPIB interface is chosen to connect with various instruments (such as, current amplifier, lock-in amplifier, digital voltmeter and programmable high voltage power supply etc.) The control and analysis program is written in the TBASIC programming language. This system can also be used to control several stepping motors, as well as to control the opening and closing of the shutters. This computer program can be used for both the visible spectrum region from 200 to 750 NM and the near infrared region from 750 to 2500 NM. In this paper, the reference reflectance spectrophotometer, the computer program, and the resutts of the performance test are described.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"503 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134033162","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of the New PTB Highly Accurate AC Power Source 新型PTB高精度交流电源的研制
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671336
R. Bergeest, M. Kahmann, M. Klonz, R. Zirpel, P. Miljanic, B. Stojanovic
{"title":"Development of the New PTB Highly Accurate AC Power Source","authors":"R. Bergeest, M. Kahmann, M. Klonz, R. Zirpel, P. Miljanic, B. Stojanovic","doi":"10.1109/CPEM.1988.671336","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671336","url":null,"abstract":"A highly accurate ac power source for unity power factor with an expected total uncertainty of a few parts in 10/sup 6/ to be used in the power frequency range is described. The rms value of the output voltage is continuously readjusted to a precisely known dc reference voltage using a multijunction thermal converter. A reference current is derived from the output voltage using an accurately known reiistor. The output current of a transconductance amplifier is compared to this reference current by means of a current comparator and continuously readjusted.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134600344","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Electrical Measurement System in the Federal Republic of Germany 德意志联邦共和国电气测量系统
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671282
V. Kose, E. Fay, F. Melchert
{"title":"Electrical Measurement System in the Federal Republic of Germany","authors":"V. Kose, E. Fay, F. Melchert","doi":"10.1109/CPEM.1988.671282","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671282","url":null,"abstract":"Before 1900 the Electrical Measurement System in Germany was founded based on the \"Law on electrical Units\" from 1898. This paper describes the present status of the tasks and organization of the legal and the industrial metrology in the area of electricity in the Federal Republic of Germany and West Berlin. The \"Deutscher Kalibrierdienst\" DKD, which was founded 1977, assures traceability to national standards of measurements done in industry for quality control. The links of the German Electrical Measurement System to international organizations and institutions are given.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134393825","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accuracy of the ftne structure constant 精细结构常数的精度
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671185
T. Kinoshita
{"title":"Accuracy of the ftne structure constant","authors":"T. Kinoshita","doi":"10.1109/CPEM.1988.671185","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671185","url":null,"abstract":"At present the fine structure constant /spl alpha/ can be determined with a precision of better than few parts in 10/sup 7/ in four independent ways. They are based on the ac Josephson effect, the quantized Hall effect, the muonium hfs, and the anomalous magnetic.moment of the electron. Further improvements of these results and their implications to physics and metrology will be discussed.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132802214","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Convenient Error Estimating Method for Current Transformer Test System Using Current Comparator 基于电流比较器的电流互感器测试系统误差估计方法
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671265
K. Takahashi
{"title":"Convenient Error Estimating Method for Current Transformer Test System Using Current Comparator","authors":"K. Takahashi","doi":"10.1109/CPEM.1988.671265","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671265","url":null,"abstract":"","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"190 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114092766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
1/f noise in electrical components caused by the positive thermal feedback in self-generating syste 1/f自生系统中由热正反馈引起的电气元件噪声
1988 Conference on Precision Electromagnetic Measurements Pub Date : 1988-06-07 DOI: 10.1109/CPEM.1988.671175
H. Seppa, T. Korkolainen, T. Ryhanen
{"title":"1/f noise in electrical components caused by the positive thermal feedback in self-generating syste","authors":"H. Seppa, T. Korkolainen, T. Ryhanen","doi":"10.1109/CPEM.1988.671175","DOIUrl":"https://doi.org/10.1109/CPEM.1988.671175","url":null,"abstract":"The positive thermal feedback in a self-generating system is shown to convert thermally induced white noise into 1/f noise. According to this model the slope of the low frequency noise spectrum is very close to unity since the real component evacuates its heat into the three-dimensional space. The theory predicts that the 1/f noise exceeds white noise below the frequency characterizing both the geometric structure of the component and the thermal properties of the surroundings. Consequently, the uncertainty of the measurement is inversely proportional to the physical size of the component or the standard.","PeriodicalId":326579,"journal":{"name":"1988 Conference on Precision Electromagnetic Measurements","volume":"134 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116340294","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信