V. Soni, Arvind Gupta, R. Kumar, N. Suman, T. Ram, Reena Sharma, T. S. Datta, S. Kar
{"title":"Post-Quench electromechanical analysis of 1.5 T whole body clinical MRI system","authors":"V. Soni, Arvind Gupta, R. Kumar, N. Suman, T. Ram, Reena Sharma, T. S. Datta, S. Kar","doi":"10.5958/2349-2120.2019.00033.5","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00033.5","url":null,"abstract":"A 1.5 T superconducting magnet has been designed for the whole-body clinical MRI scanner. The stored energy (∼4.5 MJ) of the magnet if released during a quench, can adversely affect the coil by raising its temperature and the associated voltage across the coil. Any quench in the MRI magnet induces an eddy current on various components of the magnet system such as bobbin, thermal radiation shield, etc. A passive quench protection scheme has been designed and simulated for the MRI magnet. The hot-spot temperature and the peak voltage in the magnet respectively are 136 K and 2.15 kV. The quench induced eddy current and the associated mechanical stresses have also been simulated for the various components. The peak density of the eddy current on the magnet bobbin and the thermal radiation shield are 375.5 A/cm2 and 2316 A/cm2 respectively. Whereas the peak mechanical stresses are 40.48 MPa and 11 MPa for the bobbin and the thermal radiation shield respectively. This paper briefly discusses the quench protection scheme, quench-induced eddy current and its associated mechanical stresses on various components of the magnet system.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133396196","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analytical model of cryo-target in thermo-vacuum chamber","authors":"M. Hasan","doi":"10.5958/2349-2120.2015.00024.2","DOIUrl":"https://doi.org/10.5958/2349-2120.2015.00024.2","url":null,"abstract":"Nitrogen and Helium based Cryo-Target (CT) systems are used for various experimental, industrial and testing applications in high vacuum chambers. Thermal performance of such systems depends upon a number of factors such as thermal exchange coefficient of coolant, various forms of heat losses, coolant properties, CT plate characteristics, externally applied heat loads etc. Therefore an analytical formulation is necessary in order to quantify the effect of such factors over thermal performance of CT system. In this paper analytical model is developed for flat plate CT system based on the positive root of heat balance quartic equation. Important analytical formulas related to characterization of thermal performance of CT systems are presented. This paper doesn't consider mixed phase flow in CT.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"16 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133488005","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Tokamak: A device for nuclear fusion","authors":"Y. Saxena","doi":"10.5958/2349-2120.2016.00001.7","DOIUrl":"https://doi.org/10.5958/2349-2120.2016.00001.7","url":null,"abstract":"Tokamak is a plasma confinement device, which uses a combination of magnetic fields to confine hot plasma. Tokamak research has made rapid progress in terms of plasma confinement parameters and temperatures and it is a strong candidate for magnetic confinement based Nuclear Fusion Reactor. The paper gives introduction to tokama device, reviews the status to tokamak research with emphasis on tokamak research in India.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133643633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CFD analysis of the evaporating two-phase flow in the slug flow regime of a cryogenic fluid in a microchannel","authors":"J. Akhter, S. Pal, C. Nandi","doi":"10.5958/2349-2120.2019.00027.x","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00027.x","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"75 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131284758","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CFD analysis of axial pump of lox booster turbo pump for a staged combustion cycle based rocket engine","authors":"A. Mishra, P. Ghosh","doi":"10.5958/2349-2120.2017.00014.0","DOIUrl":"https://doi.org/10.5958/2349-2120.2017.00014.0","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127223933","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Z. A. Naser, C. Nandi, M. Ahammed, M. Mondal, Pankaj Kumar, M. Dey, Anjan Dutta Gupta, G. Pal
{"title":"Study of fluid flow parameters of cryogen distribution system for E-Linac facility of RIB Project at VECC, Kolkata","authors":"Z. A. Naser, C. Nandi, M. Ahammed, M. Mondal, Pankaj Kumar, M. Dey, Anjan Dutta Gupta, G. Pal","doi":"10.5958/2349-2120.2017.00021.8","DOIUrl":"https://doi.org/10.5958/2349-2120.2017.00021.8","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133734099","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
U. Panda, S. Pal, R. Dey, N. Datta, A. Mukherjee, Anupam Mandal
{"title":"Speech alarm and cycle helium gas monitoring of helium refrigerator","authors":"U. Panda, S. Pal, R. Dey, N. Datta, A. Mukherjee, Anupam Mandal","doi":"10.5958/2349-2120.2014.00814.0","DOIUrl":"https://doi.org/10.5958/2349-2120.2014.00814.0","url":null,"abstract":"Two helium liquefiers are running round-the-clock in parallel. One of them is always connected to the Superconducting Cyclotron in refrigeration mode. EPICS based alarm system is running with alert sound in computer speaker. But the fault cannot be located without opening the fault screen. An audible English speech alarm system was envisaged and implemented in EPICS platform. Voice message are now being played in relation to faults or alarms. In continuously operating refrigeration system pure helium gas inventory is an important parameter to log. We need to calculate total pure equivalent helium cycle inventory. Now, we have put these calculations together in EPICS controller. This continuously calculates displays and archives the pure equivalent cycle helium gas. If any leak develops in the process, this trend gives a quick indication.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115019266","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. J. Thomas, K. Shafi, Mathew Skaria, G. Vivek, Jobin Thomas, K. Rakesh, V. Tanna, P. Panchal, S. Kasthurirengan
{"title":"Capacitance measurement circuits for void fraction sensors for cryogenic fluids","authors":"R. J. Thomas, K. Shafi, Mathew Skaria, G. Vivek, Jobin Thomas, K. Rakesh, V. Tanna, P. Panchal, S. Kasthurirengan","doi":"10.5958/2349-2120.2019.00030.x","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00030.x","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117162273","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Numerical analysis of miniature coaxial Stirling type pulse tube cryocooler with a modified reservoir","authors":"Derick Abraham, B. T. Kuzhiveli","doi":"10.5958/2349-2120.2018.00013.4","DOIUrl":"https://doi.org/10.5958/2349-2120.2018.00013.4","url":null,"abstract":"A Numerical model of a compact coaxial Stirling pulse tube cryocooler with a cooling capacity not less than 2W at 80K is done. The performance characteristics with varying geometrical parameters are simulated. The Inertance Pulse Tube Cryocooler (IPTC) with a modified reservoir is suggested, where the reverse fluctuation of pressure in the compressor case is used instead of the steady pressure in the reservoir to shift the phase of the flow velocity the hot end of the pulse tube. Therefore, the large reservoir volume of the cryocooler could be reduced, to make the cryocooler compact. The performance of the cryocooler was investigated and compared with the IPTC. The simulation results show that the cryocooler with modified reservoir can work as efficient as inertance type pulse tube cryocooler.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"107 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120863248","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of bottom heating on thermal stratification and self-pressurization in a cryogenic tank","authors":"S. Vishnu, T. H. Rahuldas, B. T. Kuzhiveli","doi":"10.5958/2349-2120.2018.00022.5","DOIUrl":"https://doi.org/10.5958/2349-2120.2018.00022.5","url":null,"abstract":"The aerodynamic side wall heating is an inevitable phenomenon happening in a cryogenic propellant tank during a space mission. The side wall heating leads to thermal stratification and self-pressurization of propellant tank. The rise in propellant temperature may also leads to cavitation in pump which has to be avoided. So modeling of stratification in cryogenic tank is essential as the liquid propellant must meet the pump inlet condition. Self-pressurization in a cylindrical tank which is partially filled with liquid hydrogen is investigated numerically under constant side wall heating and varying bottom heating. The Volume of Fluid (VOF) method is employed as well as a phase change model. The model is validated with experimental data reported in the literature. Numerical results indicate that considerable amount of side wall heating goes into raising the temperature of the fluid inside the boundary layer which enhances the stratification. By providing controlled bottom heating, some agitation is introduced, which disturbs the formation of free convection boundary layer. Due to the absence of well-defined free convection boundary layer flow in the tank, most of the side wall heating goes into raising the temperature of the bulk liquid, resulting delayed stratification.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121955204","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}