D. Nadig, G. Paul, V. Pavan, C. Mahishi, H. Sudharshan, Anshuman Dubey
{"title":"Wear properties of Polytetrafluroethylene (PTFE) at cryogenic temperature","authors":"D. Nadig, G. Paul, V. Pavan, C. Mahishi, H. Sudharshan, Anshuman Dubey","doi":"10.5958/2349-2120.2018.00029.8","DOIUrl":"https://doi.org/10.5958/2349-2120.2018.00029.8","url":null,"abstract":"Conventional lubricants like oil and grease cannot be used for cryogenic applications, since they tend to solidify at low temperatures. For these applications, solid lubricants like Polytetrafluroethylene (PTFE) and its carbon composites are extensively used. In this experimental study, the tribological properties of cryotreated and untreated PTFE and its composites are studied at room and cryogenic temperatures. A dedicated pin on disc type cryotribometer has been designed and developed to study the wear. Results of tribological experiments carried for fixed time duration of 10 minutes, constant speed of 400rpm and track diameter of 60mm under the applied load of 10N are studied and analysed.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129778978","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. V. Rijin, M. Xavier, A. Antony, J. Paul, V. Narayanan
{"title":"Mathematical modeling of cryogenic propellant tank pressurisation system provided with heat exchanger","authors":"K. V. Rijin, M. Xavier, A. Antony, J. Paul, V. Narayanan","doi":"10.5958/2349-2120.2017.00015.2","DOIUrl":"https://doi.org/10.5958/2349-2120.2017.00015.2","url":null,"abstract":"Pressurisation of propellant tank during flight is required to maintain specified NPSP (Net Positive Suction Pressure) at pump inlet and also to ensure structural stability against buckling under flight loads. Selection of propellant tank pressurisation system plays a vital role in configuring a high performance propulsion stage. Heat exchanger is used to heat the pressurant gas so that overall mass of pressurization system is reduced considerably. When heated gas is used for pressurisation, it is imperative to quantify the mass of liquid attaining temperature higher than the acceptable value for cavitation free pump operation. Heat exchanger design is a trade-off between optimum pressurant gas temperature, the stratified propellant mass and pressurization system mass. The objective of this paper is to mathematically model the pressurization system for Liquid Oxygen (LOX) tank employed in a cryogenic propulsion stage.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128616357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Design optimization of perforated plate heat exchangers using taguchi method","authors":"L. R. Raju, T. K. Nandi","doi":"10.5958/2349-2120.2015.00016.3","DOIUrl":"https://doi.org/10.5958/2349-2120.2015.00016.3","url":null,"abstract":"Performance of a Perforated plate heat exchanger (PPHE) depends on many design variables such as plate thickness, spacer thickness, pore diameter, porosity etc. For a given heat duty, these parameters can be optimized for maximizing effectiveness, minimizing volume and minimizing or limiting pressure drop. In this paper an attempt has been made for optimization of the design variables of a PPHE so that effectiveness of the heat exchanger per unit volume is maximized under the constraints of fluid pressure drop and length of the heat exchanger. Unlike the conventional approach, importance is given to the length of the heat exchanger which is limited to the available space inside the vacuum chamber of the diffusion bounding machine or the space available in a specific application. Using the given length of the heat exchanger and allowable pressure drop, the problem has been defined in unconstrained form and solved by Taguchi method.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130527747","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Verma, N. Shivaprakash, U. Behera, S. Kasthurirengan, G. Bharath, R. Gangradey
{"title":"Thermal conductivity studies of epoxy-aluminium composites (300 K-4.5 K) for the development of cryosorption pumps","authors":"R. Verma, N. Shivaprakash, U. Behera, S. Kasthurirengan, G. Bharath, R. Gangradey","doi":"10.5958/2349-2120.2018.00018.3","DOIUrl":"https://doi.org/10.5958/2349-2120.2018.00018.3","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114066056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of lab scale sub-cooled liquid nitrogen facility for high temperature superconductor applications","authors":"N. Bairagi, H. Nimavat, D. Sonara, V. Tanna","doi":"10.5958/2349-2120.2019.00024.4","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00024.4","url":null,"abstract":"The technological advances in high temperature superconductors (HTS) have led to its use in various high voltage and high current applications. HTS based devices have huge application prospect compared to low temperature superconductors (LTS) owing to their higher engineering current density, higher critical temperature (hence higher operating temperature) resulting in high power density and lower investment on cryogenics. Here we report the development of sub-cooled liquid nitrogen facility for cooling small scale HTS application with single phase liquid nitrogen under a temperature range of 64 K-77 K. We have sub-cooled liquid nitrogen inside commercially available 50 L Dewar by boiling nitrogen under reduced pressure. As a proof of principle, we have cooled a 1 meter long vacuum insulated flexible cryogenic transfer line to 70 K using sub-cooled nitrogen. This same facility can be used to efficiently cool future High Temperature Superconductor (HTS) based applications at a laboratory scale.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114629608","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Critical current density and pinning mechanism in Hetero structure of Bi-2212 and MgB2 superconductors","authors":"M. Padmavathi, R. Singh","doi":"10.5958/2349-2120.2020.00028.X","DOIUrl":"https://doi.org/10.5958/2349-2120.2020.00028.X","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116177790","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Nikhil, K. Monisha, V. Unnikrishnan, R. Balakrishnan, A. Suresh Kumar, A. M. Nallaperumal
{"title":"Studies on premoulded pad for cryo insulation","authors":"P. Nikhil, K. Monisha, V. Unnikrishnan, R. Balakrishnan, A. Suresh Kumar, A. M. Nallaperumal","doi":"10.5958/2349-2120.2021.00011.x","DOIUrl":"https://doi.org/10.5958/2349-2120.2021.00011.x","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127900784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Bathula, D. K. Sharma, A. S. Gour, U. K. Choudhury, V. Rao
{"title":"A study on high temperature superconducting (HTS) double pancake field coils for HTS synchronous machines applications","authors":"V. Bathula, D. K. Sharma, A. S. Gour, U. K. Choudhury, V. Rao","doi":"10.5958/2349-2120.2019.00035.9","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00035.9","url":null,"abstract":"","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115859520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Khare, A. Agarwal, Tamal Ghosh, U. Bhunia, C. Nandi, A. Roy, J. Pradhan, M. Dey, S. K. Thakur
{"title":"Fabrication of racetrack-type double pancake HTS coil for K500 extraction beam line steering magnet","authors":"V. Khare, A. Agarwal, Tamal Ghosh, U. Bhunia, C. Nandi, A. Roy, J. Pradhan, M. Dey, S. K. Thakur","doi":"10.5958/2349-2120.2018.00015.8","DOIUrl":"https://doi.org/10.5958/2349-2120.2018.00015.8","url":null,"abstract":"A High Temperature Superconductor (HTS) based cryorefrigerator assisted steering magnet sunder development at VECC for the extraction beam line of K500 cyclotron. The magnet designed is specified for ± 3 degree horizontal correction and ± 1.5 degree of vertical correction of the beam of maximum rigidity of 3.3 T-m. The magnet is composed of two sets of double pancake racetrack coil-one set for vertical field (By) and other for horizontal field inside the return iron yoke. Double pancake coils are fabricated in-house using BSCCO-2223 HTS tapes by wet winding technique using cryogenic grade epoxy. The critical characteristics of the coils are tested at liquid nitrogen temperature in terms of critical current and index parameters. The paper describes the winding details of double pancake coils and test results at liquid nitrogen temperature.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"104 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130253299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Chakravarty, M. Jadhav, Mukesh Goyal, D. S. Pilkhwal
{"title":"Conceptualization and preliminary studies on the development of a 2K refrigeration system at BARC","authors":"A. Chakravarty, M. Jadhav, Mukesh Goyal, D. S. Pilkhwal","doi":"10.5958/2349-2120.2019.00004.9","DOIUrl":"https://doi.org/10.5958/2349-2120.2019.00004.9","url":null,"abstract":"Conceptualization and preliminary studies on the development of a 2K helium refrigeration system at BARC are reported in this article. Two different refrigeration schemes are considered and studied. In Scheme A, a separate cold box with 2 heat exchangers, a liquid helium bath and a sub atmospheric heat exchanger is considered and 2K refrigeration capacities for different liquid helium flow rates corresponding to LHP 50 and LHP 100 (BARC helium liquefiers), are computed and reported. In Scheme B, the 2K refrigeration system is considered to work in tandem with a back-up 4.5K helium liquefier (LHP 50/LHP 100), receiving a stream of cold supercritical helium from the liquefier. Different cases, with and without liquid nitrogen precooling options of the 4.5K liquefier, are considered. After preliminary studies, Scheme B is preferred over Scheme A and the process inputs for the sub atmospheric pressure heat exchanger are also arrived at and presented.","PeriodicalId":320122,"journal":{"name":"Indian Journal of Cryogenics","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132979333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}