Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)最新文献

筛选
英文 中文
Investigations of dose rate effects on CMOS submicronic technologies 剂量率对CMOS亚微米技术影响的研究
T. Corbiere, J. L. Venturin
{"title":"Investigations of dose rate effects on CMOS submicronic technologies","authors":"T. Corbiere, J. L. Venturin","doi":"10.1109/REDW.1995.483403","DOIUrl":"https://doi.org/10.1109/REDW.1995.483403","url":null,"abstract":"Majority of the TOTAL DOSE evaluations of MOS devices are made by using Cobalt 60 sources at dose rates which are far from the real conditions found in the natural space environment. When geostationary satellites experienced dose rate around 1 to 2 Krad(Si) per year, the dose rate recommended by the two major test procedures vary from 30 Rad(Si)/hour up to 300Krad(Si)/hour. One can think that those test conditions do not reflect the permanent effects that could occur during the lifetime of the mission. The objective of the study is to evaluate the dose rate effects on circuits representative of the MATRA MHS state-of-the-art CMOS technology used for space parts manufacturing and provide recommendations for future new CMOS technologies characterizations.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134017863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Single event effect proton and heavy ion test results in support of candidate NASA programs 单事件效应质子和重离子测试结果支持候选NASA项目
K. Label, A. Moran, D. Hawkins, A. Sanders, C. Seidleck, H. Kim, J. Fomey, E. Stassinopoulos, P. Marshall, C. Dale, R. Barry
{"title":"Single event effect proton and heavy ion test results in support of candidate NASA programs","authors":"K. Label, A. Moran, D. Hawkins, A. Sanders, C. Seidleck, H. Kim, J. Fomey, E. Stassinopoulos, P. Marshall, C. Dale, R. Barry","doi":"10.1109/REDW.1995.483259","DOIUrl":"https://doi.org/10.1109/REDW.1995.483259","url":null,"abstract":"We present proton and heavy ion single event effect (SEE) ground test results for candidate spacecraft electronics. The variety of analog and digital devices tested includes ADCs, DC-DC converters, DRAMs, linear devices, and microprocessors.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125037736","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Radiation effects in Micrel MIC4427 MOSFET drivers Micrel MIC4427 MOSFET驱动器中的辐射效应
M. Skipper, K. Atkins, G. Hopkinson, K. Label
{"title":"Radiation effects in Micrel MIC4427 MOSFET drivers","authors":"M. Skipper, K. Atkins, G. Hopkinson, K. Label","doi":"10.1109/REDW.1995.483376","DOIUrl":"https://doi.org/10.1109/REDW.1995.483376","url":null,"abstract":"Results of Co-60 total dose and heavy-ion latch-up testing indicate that the MIC4427 is capable of being used as a CCD clock driver in low dose rate space environments, up to a total dose of >50 krad(Si).","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131009353","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Cold X-ray simulation technology development at Phoenix 在凤凰城开发冷x射线模拟技术
E. Nolting, L. Miles, J. Miller, V. Kenyon, W. Spicer, J. Draper, C. Parsons, F. Warnock, A. Fisher, G. Peterson, R. Terry, M. Krishan, R. Prasad, G. Rondeau, J. Sethian, N. Pereira, F. Cochran, R. Smith
{"title":"Cold X-ray simulation technology development at Phoenix","authors":"E. Nolting, L. Miles, J. Miller, V. Kenyon, W. Spicer, J. Draper, C. Parsons, F. Warnock, A. Fisher, G. Peterson, R. Terry, M. Krishan, R. Prasad, G. Rondeau, J. Sethian, N. Pereira, F. Cochran, R. Smith","doi":"10.1109/REDW.1995.483406","DOIUrl":"https://doi.org/10.1109/REDW.1995.483406","url":null,"abstract":"When operated in its plasma radiation source (PRS) mode, the Phoenix simulator employs a 1.6 MJ marx capacitor bank to drive a nominal 3/8 /spl Omega/ diode. During its development, both aluminum wire and puff gas (argon and krypton) loads have been tested. To date, radiation outputs of 50 kJ aluminum and 20 kJ argon K-line radiation have been achieved at 65% of maximum energy storage. This paper emphasizes three aspects of the Phoenix PRS: (1) the operation of the fast rise time gas puff valve, (2) measurements of the implosion dynamics, and (3) the development of a solid deuterium debris shield.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"39 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116655674","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Single event upset and latchup measurements in avionics devices using the WNR neutron beam and a new neutron-induced latchup model 利用WNR中子束和一种新的中子诱导闭锁模型测量航空电子设备的单事件扰动和闭锁
E. Normand, J. Wert, P. Majewski, D. Oberg, W.G. Bartholet, S. Davis, M. Shoga, S. Wender, A. Gavron
{"title":"Single event upset and latchup measurements in avionics devices using the WNR neutron beam and a new neutron-induced latchup model","authors":"E. Normand, J. Wert, P. Majewski, D. Oberg, W.G. Bartholet, S. Davis, M. Shoga, S. Wender, A. Gavron","doi":"10.1109/REDW.1995.483373","DOIUrl":"https://doi.org/10.1109/REDW.1995.483373","url":null,"abstract":"Microelectronic devices used in avionics were tested in the WNR beam, simulating atmospheric neutrons. The SEU upset rates for ARINC 429 receivers agree with rates in memories, and neutron-induced latchup was measured in the LCA100 K and 200 K gate arrays and compared against a new neutron-induced latchup model.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134235109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 23
PL-GEOSpace: three-dimensional visualization of the dynamic space environment PL-GEOSpace:动态空间环境的三维可视化
G. Ginet, R. Biasca, M. Tautz
{"title":"PL-GEOSpace: three-dimensional visualization of the dynamic space environment","authors":"G. Ginet, R. Biasca, M. Tautz","doi":"10.1109/REDW.1995.483405","DOIUrl":"https://doi.org/10.1109/REDW.1995.483405","url":null,"abstract":"PL-GEOSpace is a software package designed to provide a user-friendly graphical interface to a variety of near-Earth space environment models and applications with an emphasis on three-dimensional visualization. A brief description of the design and capabilities of PL-GEOSpace is given.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"2008 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125612974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Confirmation of calculated error rates in a logic circuit using a pulsed laser 用脉冲激光确认逻辑电路中的计算错误率
S. Buchner, J. Melinger, D. McMorrow, M. Baze, W. G. Bartholet
{"title":"Confirmation of calculated error rates in a logic circuit using a pulsed laser","authors":"S. Buchner, J. Melinger, D. McMorrow, M. Baze, W. G. Bartholet","doi":"10.1109/REDW.1995.483374","DOIUrl":"https://doi.org/10.1109/REDW.1995.483374","url":null,"abstract":"Understanding the generation and propagation of single event upsets (SEU) induced by energetic ions passing through logic circuits is difficult due to the fact that neither the location of the ion strike, nor the time at which it occurs, can readily be determined. The task is greatly simplified with a pulsed laser because the laser light can be focused to a small spot and positioned on a particular node in the circuit, making it possible to identify the location of the upset. Furthermore, the time at which the upset occurs can also be established by synchronizing the laser pulse to the circuit clock. In this way, a great deal of information regarding the sensitivity of logic circuits to SEUs can be obtained. We have used the pulsed laser to generate upsets in a logic circuit. The measured upset rates agreed quite well with calculated error rates.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"162 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132604606","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
TRENDS IN DEVICE SEE SUSCEPTIBILITY FROM HEAVY IONS 器件的趋势可以看出对重离子的敏感性
D. Nichols, J. Coss, K. Mccarty, H. Schwartz, G. Swift, R. Watson, R. Koga
{"title":"TRENDS IN DEVICE SEE SUSCEPTIBILITY FROM HEAVY IONS","authors":"D. Nichols, J. Coss, K. Mccarty, H. Schwartz, G. Swift, R. Watson, R. Koga","doi":"10.1109/REDW.1995.483258","DOIUrl":"https://doi.org/10.1109/REDW.1995.483258","url":null,"abstract":"The sixth set of heavy ion single event effects (SEE) test data have been collected since the last IEEE publications in December issues of IEEE - Nuclear Science Transactions for 1985, 1987, 1989, 1991, and the IEEE Workshop Record, 1993. Trends in SEE susceptibility (including soft errors and latchup) for state-of- are evaluated.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116083526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Total dose characterization of the PACE 1750A microprocessor chipset PACE 1750A微处理器芯片组的总剂量特性
M. Regula, O. Pedersen, R. R. Konegen
{"title":"Total dose characterization of the PACE 1750A microprocessor chipset","authors":"M. Regula, O. Pedersen, R. R. Konegen","doi":"10.1109/REDW.1995.483400","DOIUrl":"https://doi.org/10.1109/REDW.1995.483400","url":null,"abstract":"Total dose irradiation characterization testing of the PACE 1750A SOS chipset built on commercial SOS material and of the chipset manufactured using the Westinghouse radiation enhanced process based on 5416 Aerorad Sarnoff silicon epilayer wafers has been performed by Performance Semiconductor Corporation (PSC) and by Daimler-Benz Aerospace (Dasa). Total dose tolerance of the non-hardened chipsets varied between <10 krad(Si) and >100 krad(Si). The radiation hardened chipsets were all radiation hard to levels /spl ges/100 krad(Si).","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121838499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Heavy ion, proton and Co-60 radiation evaluation of 16 Mbit DRAM memories for space application 空间应用16mbit DRAM存储器的重离子、质子和Co-60辐射评价
R. Harboe-Sørensen, R. Muller, S. Fraenkel
{"title":"Heavy ion, proton and Co-60 radiation evaluation of 16 Mbit DRAM memories for space application","authors":"R. Harboe-Sørensen, R. Muller, S. Fraenkel","doi":"10.1109/REDW.1995.483375","DOIUrl":"https://doi.org/10.1109/REDW.1995.483375","url":null,"abstract":"This paper presents the results of a heavy ion, proton and Co-60 radiation evaluation programme carried out on a large number of current available 16 Mbit DRAMs. Testing issues, results obtained and recommendations are given for 15 difference DRAM types representing 8 manufacturers.","PeriodicalId":302588,"journal":{"name":"Proceedings of 1995 IEEE Nuclear and Space Radiation Effects Conference (NSREC'95)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131731669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书