2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering最新文献

筛选
英文 中文
A study of magnetic domain distribution in ferrite by magnetic force microscopy 磁力显微镜下铁氧体磁畴分布的研究
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559070
Wei-Sheng Hsu, Min-Da Yang, Yichuan Wang, Li-Jiaun Lin
{"title":"A study of magnetic domain distribution in ferrite by magnetic force microscopy","authors":"Wei-Sheng Hsu, Min-Da Yang, Yichuan Wang, Li-Jiaun Lin","doi":"10.1109/NANOMED.2009.5559070","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559070","url":null,"abstract":"In this study, vibration sample measurement (VSM) and magnetic force microscopy (MFM) have been used to observe the magnetic behavior and identify the magnetic domain distribution of NiZn ferrite, which was synthesized via chemical route and spray deposition method. Cases considered in the present study involve the types of NZF1 and NZF2 NiZn ferrite. VSM results show that the films with different deposition rate have the saturation magnetization from 200 to 900 emu/cm3, and the resistance of the film is about 1 Mohm. The ferromagnetic resonance frequency is 1 GHz approximately. MFM results show that images were also discussed the domain wall motion between the particle of NiZn ferrite, which generated the different magnetic moment direction. Therefore, MFM could obtain the relationship results between the qualitative magnetic domain structure distribution and surface morphology of two types of NiZn ferrite.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"1 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114088766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Micro integrated laser Doppler blood flow sensor and its application to dehydration prevention 微集成激光多普勒血流传感器及其在脱水预防中的应用
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559082
Hirofumi Nogami, W. Iwasaki, F. Matsuoka, K. Akase, Y. Kimura, A. Onoe, E. Higurashi, S. Takeuchi, M. Kido, M. Furue, R. Sawada
{"title":"Micro integrated laser Doppler blood flow sensor and its application to dehydration prevention","authors":"Hirofumi Nogami, W. Iwasaki, F. Matsuoka, K. Akase, Y. Kimura, A. Onoe, E. Higurashi, S. Takeuchi, M. Kido, M. Furue, R. Sawada","doi":"10.1109/NANOMED.2009.5559082","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559082","url":null,"abstract":"Using Micro Electro Mechanical Systems (MEMS) technologies, we have developed the world's smallest, lightest, and least power-consuming integrated laser Doppler blood flow sensor. Unlikely commercial optical fiber type blood flow instruments, the structure of our sensor need not optical fiber, which is also invulnerable to any movements of the person wearing it. Therefore our sensor enables stable measurement the person raising an arm with our sensor attached to a finger-tip (arm-raising test). In this paper, we present a new structure of an integrated laser Doppler blood flow sensor and its application to dehydration prevention using our sensor and arm-raising test.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117111066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Construct the micro fluidic nozzles to electrospray ionizing large biomolecules in mass spectrometry analyzing 在质谱分析中,构建了电喷雾电离大分子的微流体喷嘴
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559112
K. Weng, Mei-Ya Wang, Chien-Chih Huang, C.-H. Kuo
{"title":"Construct the micro fluidic nozzles to electrospray ionizing large biomolecules in mass spectrometry analyzing","authors":"K. Weng, Mei-Ya Wang, Chien-Chih Huang, C.-H. Kuo","doi":"10.1109/NANOMED.2009.5559112","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559112","url":null,"abstract":"A novel and simple technique is implemented to construct the spray nozzle tips on the glass microchips with 50µm width by 20µm depth channels. The microchips are fabricated in following the conventional photolithography and glass wet etching processes. The nozzles are diced using the wafer dicing machines, which is integrated the nozzle fabrication step at the same dicing step. The chips are cut through the substrate in the x−y plane and saw the depth of the chip exquisitely to form the spray nozzle in the z-axis. The SEM view of nozzles and Taylor cone of electrospray are demonstrated. The green fluorescent protein is the sample to verify the spray nozzle function and mass spectrometry was obtained.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127721481","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of the annealing effect of low-temperature oxide on the etch rate in TMAH solutions for micro-heater applications 低温氧化物对微加热器TMAH溶液中蚀刻速率的退火影响研究
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559093
Wen-Chie Huang, Chung-Nan Chen, Shang-Hung Shen, Cheng Chen
{"title":"Study of the annealing effect of low-temperature oxide on the etch rate in TMAH solutions for micro-heater applications","authors":"Wen-Chie Huang, Chung-Nan Chen, Shang-Hung Shen, Cheng Chen","doi":"10.1109/NANOMED.2009.5559093","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559093","url":null,"abstract":"Suspended structures are frequently used in some micro-electro-mechanical system (MEMS) devices. They are usually protected and supported by silicon oxide. Because the suspended structures are released from the silicon substrate in various etchants, the etch resistivity of the oxide layer is very important for suspended structure fabrication. In this paper, we improve the etch resistivity of low temperature chemical vapor deposition (CVD) silicon oxide layers by using annealing process to substitute thermal oxide grown in a high-temperature and high-cleanness furnace. We prepared thermal oxide and CVD oxide samples and then measured the etch rates after tetramethyl ammonium hydroxide (TMAH) anisotropic etching process and dry etch process. According to the experiment data, we found that the etch rates of CVD oxide were slightly decreased in dry etch and obviously decreased in TMAH solution. The etch rates of 600 °C annealed TEOS based oxide and 600 °C annealed SiH4 based oxide in 25 wt.% TMAH at 80 °C are 1.1 and 0.7 Å/min respectively. The etch resistivity of CVD oxide can compete the etch resistivity of thermal oxide when annealing temperature is up to 600 °C. The stress characteristics of annealed oxide layer were also measured in this paper. The stress has a minimum value at 600 °C annealing temperature. In our work, a single crystalline silicon heater was successfully completed by using annealed CVD oxide as passivation layer. The heater with a resistance of 200 ohms glowed as bias current is up to 38 mA. We also simulated and characterized the temperature distribution of the microheater. The ANSYS simulation shows the central temperature of the microheater is 1135 °C as the bias power is 0.59 W.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127816717","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The effect of voltage and diameter of anodic porous alumina in acid solutions 电压和直径对酸溶液中阳极多孔氧化铝的影响
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559105
G. Chen, Chengpeng Liu
{"title":"The effect of voltage and diameter of anodic porous alumina in acid solutions","authors":"G. Chen, Chengpeng Liu","doi":"10.1109/NANOMED.2009.5559105","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559105","url":null,"abstract":"Anodic aluminum oxide (AAO) is fabricated by electrochemical anodization of aluminum. This work is focused on the optimization on the diameter of the pores in anodic aluminum oxide (AAO) template. The Al sheet (20 × 20 × 0.15 mm) and Al (1 µm) deposited on silicon wafers (p-type) were used for anodic aluminum oxide (AAO) growth. The growing time, temperatures, kinds of electrolyte, working voltage were used to optimize the anodization of alumina. Besides, the effect of working voltage on the diameter of pores was also investigated. The porous array of alumina film has a uniform; closely packs honeycomb structure approximately 15 nm to 150 nm in diameter. Because of this, the structure is a good material for photonic crystal application in the future. This structure of alumina film is observed by scanning electrical microscope (SEM), and the density of porous channels was also obtained (1010 /cm2).","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128661567","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A novel CMOS-compatible polysilicon/titanium thermopile 一种新型cmos兼容多晶硅/钛热电堆
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559097
Chung-Nan Chen, Wen-Chie Huang, Cheng Chen, Shang-Hung Shen
{"title":"A novel CMOS-compatible polysilicon/titanium thermopile","authors":"Chung-Nan Chen, Wen-Chie Huang, Cheng Chen, Shang-Hung Shen","doi":"10.1109/NANOMED.2009.5559097","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559097","url":null,"abstract":"In this paper, we present a 0.8-µm 1P2M CMOS process compatible polysilicon/titanium thermopile with a gold black absorption layer. Instead of an aluminum layer of 0.6 µm thickness in the first metallization process, a titanium layer of 0.1 µm thickness was introduced to the fabrication of a CMOS compatible thermopile in order to enhance sensitivity by lowering the thermal conductance of the sensor. After the CMOS process, a 1.2-mm-square floating thermopile structure was formed by using a front-side anisotropic etching process in dual-doped tetra-methyl ammonium hydroxide (TMAH) solution, in which the etch rates of aluminum thin film are relatively low. The experimental data reveal that the etch rate of a thermally evaporated aluminum film could be smaller than 10 Å/min in 5 wt.% TMAH solution with the addition of 4 gm/l ammonium peroxodisulfate (AP) and 24 gm/l silicic acid. Eventually, a 0.8-mm-square porous gold black layer was thermally evaporated upon the sensor surface to serve as an infrared absorption layer. The FTIR spectrum shows that the absorber has near perfect absorptance in the wavelength range of 5 to 15 µm. The completed thermopile sensor consists of 96 poly-Si/Ti thermocouples pairs and has a resistance of 43.5 kilo-ohms. For reducing environment noises, the sensor chip was encapsulated in a TO5 metal-can with an 8–14 µm filter. The measurement result indicates the sensor has a thermal time constant of 103 ms in atmosphere and 173 ms in a pressure of 16 mTorr respectively. In addition to an increasing time constant, the output voltage also raises by a factor of 2.3 in vacuum environment.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131186820","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Microfabrication of asymmetric planar electrodes for long-term glucose monitoring 用于长期血糖监测的非对称平面电极的微加工
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559121
Chih-Hsiu Yin, S. Parng, Jui-Tse Chen, K. Lee, Chu-Hsuan Chen, Tsung-Che Chou, Y. Chuang, Horn-Chin Lee, Yuh-Jiuan Lin
{"title":"Microfabrication of asymmetric planar electrodes for long-term glucose monitoring","authors":"Chih-Hsiu Yin, S. Parng, Jui-Tse Chen, K. Lee, Chu-Hsuan Chen, Tsung-Che Chou, Y. Chuang, Horn-Chin Lee, Yuh-Jiuan Lin","doi":"10.1109/NANOMED.2009.5559121","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559121","url":null,"abstract":"In the present study, we proposed a design of asymmetric planar electrodes for long-term monitoring of glucose level at body temperature. The asymmetric planar electrodes were fabricated by thin film technology on glass and cut as chip sensor. The glass-based chip sensor was further immobilized with glucose oxidase for glucose measuring. To investigate the stability of the glass-based chip sensor, we performed a long-term study and compared with a commercial polymer sensor. All of the experiments were carried out in phosphate buffer solution at 37°C. The result indicated that the glass-based chip senor was more stable in background signal than a commercial polymer sensor during a 18 days of study. The chip senor immobilized with glucose oxidase showed fast response time and broad detection range for glucose measurement. The present study demonstrated that our design of asymmetric planar electrodes was suitable for developing a glucose sensor with long-term stability.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125521572","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impedance spectroscopy of Chicken Infectious Laryngotracheitis Virus Based on atomic force microscopy 基于原子力显微镜的鸡传染性喉气管炎病毒阻抗谱分析
2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering Pub Date : 2009-10-01 DOI: 10.1109/NANOMED.2009.5559077
Michael B. Schulte, Zhuxin Dong, S. Tung, Jin-Woo Kim, U. Wejinya, H. Moon, B. Kong
{"title":"Impedance spectroscopy of Chicken Infectious Laryngotracheitis Virus Based on atomic force microscopy","authors":"Michael B. Schulte, Zhuxin Dong, S. Tung, Jin-Woo Kim, U. Wejinya, H. Moon, B. Kong","doi":"10.1109/NANOMED.2009.5559077","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559077","url":null,"abstract":"The AC impedance spectroscopy of Chicken Infectious Laryngotracheitis Virus (ILTV, gallid herpesvirus 1) was measured using atomic force microscopy (AFM). The result indicates a 30% difference in the absolute impedance values between the control and virus samples within a 10–65 kHz frequency range. Using an equivalent circuit of the systems and an electrical curve fitting program, the data shows the average capacitance of a single virus particle is approximately 6 nF. Based on a similar analysis of the electrical properties of polystyrene beads, the overall dielectric constant of the ILTV was determined to be approximately 2.4.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128789589","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书