{"title":"The study of polymer pressure sensor by nanocomposites with MWNT and it's characteristics testing","authors":"H.T. Chen, H. Ko, C. Gau","doi":"10.1109/NANOMED.2009.5559076","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559076","url":null,"abstract":"Polyimide (PI)-carbon nanotube composites were fabricated by in situ polymerization using multi-wall carbon nanotubes (MWNT) as fillers. The composite film was characterized by some analytical instruments to ensure its structure and good dispersion of the MWNTs in the composites. The electrical resistivity of this composite was found to vary significantly with both the temperature and the stress in the material. The PI-MWNT composites possess a very linear piezoresistive nature which can be used as a good pressure sensor material, provided with proper temperature compensation. Fabrication of a micropolymer pressure sensor using this nanocomposite sensing material is demonstrated and sensor performance is evaluated. The sensor has a higher sensitivity than a polysilicon sensor, rapid response, and is thermally stable. The sensor is suitable for mass production, and can be widely applied or integrated in a microfluidic system or biochip where pressure information is required.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"87 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122406057","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Investigation of scratching nano grooves on aluminum film","authors":"C. Y. Huang, C. Hsieh, J. Wang, C. Hsu","doi":"10.1109/NANOMED.2009.5559098","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559098","url":null,"abstract":"A mechanical machining method, scratch, is used to fabricate nano grooves in this investigation. The nanoindentation instrument with a lateral force module, which has high resolution three dimensional displacement and force sensors and actuators, is utilized to conduct the scratch tests. A Berkovich indenter with a sharp triangular pyramid diamond tip, whose tip radius is less than 50 nm, is used as a scriber to scratch aluminum film in these tests. To shape grooves, successful generation of chips to efficiently remove the material is crucial, and is affected by both scratch direction and depth. It is found that scratch the material by single face of the tip is the best direction to efficiently generate the chips. Moreover, the chips are usually attached to the end of the grooves and still needed to be removed. UV curing material is coated on the scratched sample, and is then separated from the sample after UV curing process. It is shown to be a good method to separate the chips from the sample.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"105 6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127410517","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on wafer-level packaging and electrochemical characterization of planar AgCl micro reference electrode","authors":"I. Huang, Chia-Hsu Hsieh, C. Chu","doi":"10.1109/NANOMED.2009.5559122","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559122","url":null,"abstract":"This study proposes a novel chip-level packaged planar Ti/Pd/Ag/AgCl/KCl-gel micro reference electrode for the electrochemical and biomedical sensing applications. The miniaturized reference electrode is constructed by two wafers (“Ti/Pd/Ag/AgCl quasi reference electrode wafer” and “KCl-gel cap sealing wafer”) and with a total dimension of only 9 mm (L) × 6 mm (W) × 1 mm (H), hundredfold less than the commercial Ag/AgCl reference electrode (OD = 12 mm). Many excellent characteristics were demonstrated by the optimized encapsulated solid-state micro reference electrode, including a very stable cell potential (5 mV drift voltage in 30,000 s), an approximately zero offset-voltage, a very low impedance (<1.50 kΩ) and phase shift (<8.98 °) at normal operation frequency range (0∼1 kHz), and a low electro-chemical noise spectrum.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114996884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fabrication of full glass chips with hybrid micro- and nanochannels and their application to protein concentration","authors":"Qiaohong He, Hua Lu, Shuang Chen, Heng-wu Chen","doi":"10.1109/NANOMED.2009.5559123","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559123","url":null,"abstract":"In this paper, we proposed an alternative method that is simple and cost-effective to fabricate full glass chips with hybrid micro- and nanochannels. Double-lithography and double wet-etching technique was used for the fabrication of hybrid micro and nanostructures. The microchannels were firstly constructed on a glass substrate by standard UV photolithography and wet etching technique. After washing away the rest photoresist and spinning a new layer of photoresist on the microchannel-structured glass substrate, nanochannels with the depth less than 100 nm were produced on the same substrate by second lithography and wet etching. Then the channels-structured glass substrate was sealed to a cover glass plate by using previously developed room temperature bonding technique. Without using clean room facilities and expensive instruments, micro- and nanofluidic chips with delicate structures were well fabricated. The good nature of those nanofluidic chips was demonstrated by the successful concentration of FITC-labeled bovine serum albumin via electrokinetic ion trapping.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117281384","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chin-wen Chang, Ming-Yu Lin, H. Harn, Yen-Chern Harn, Chien-Hung Chen, Kun-His Tsai, C. Hwang
{"title":"Automatic segmentation of abnormal cell nuclei from microscopic image analysis for cervical cancer screening","authors":"Chin-wen Chang, Ming-Yu Lin, H. Harn, Yen-Chern Harn, Chien-Hung Chen, Kun-His Tsai, C. Hwang","doi":"10.1109/NANOMED.2009.5559114","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559114","url":null,"abstract":"In this paper, two methods of microscopic image analysis were presented to classify the abnormal cells in Papanicolaou(Pap) smear for cervical cancer screening. Our goal is to extract those cell nuclei which are abnormally large size, bizarre shape as well as hyper density and we hope to apply this method to the different kinds of abnormal cells. The global information of the image and the local image condition were meantime considered. The reported method searched whole picture by scanning on different axes and determined the locations of abnormal cell nuclei with high contrast This developed method is also able to find cell nuclei, those were almost as bright as the background. Using the reported cytological image analysis, we successfully recognized the abnormal cells such as squamous intraepithelial neoplasia (SIL) and differentiated them from the normal epithelial cells.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"12 1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115568591","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nano-indentation patterns for Surface Enhanced Raman Scattering","authors":"Y. Lin, Chia-Wei Chang, Li‐Kai Lin, J. Liao","doi":"10.1109/NANOMED.2009.5559099","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559099","url":null,"abstract":"The technique of Surface Enhanced Raman Scattering (SERS) provides high informational content on the chemical structure of the probed substances, which makes this method a very promising tool in biomedical spectroscopy. In this study, we presented a novel method that utilizes nanoindentation to generate graphically indented patterns on Au surface. The modified Au surface was thereafter relevant to the applications of SERS. 5, 5′-Dithio-bis (2-nitrobenzoic acid) (DTNB) and Rhodamine 6G (R6G) were particularly grafted on the modified Au surface to verify an enhanced Raman Effect. DTNB was chemically adsorbed, while R6G was physically adsorbed on the modified Au surface. The particularly modified Au surfaces exhibited significant SERS enhancements and possibly applied for microorganism detection.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129064207","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Test on acoustic resonance characteristic of PTFE micro/nano-aperture membrane for nanobiomedical application","authors":"Wanfeng Lin, W. Lou, Xin Li, Jing Xu","doi":"10.1109/NANOMED.2009.5559131","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559131","url":null,"abstract":"This study investigate the potential biomedical application of micro/nano-aperture membrane fabricated with Polytetrafluoroethylene (PTFE). Experimental work is carried out to examine the membrane's sound transmission/absorption characteristics under the condition of different aperture diameter, thickness and cavity depth of tube. It is discovered that when there is no air layer besides the tested membrane, sound transmission is not affected. When there is sound layer, it is resonant sound absorption. In the frequency range of 100–1500Hz, it is low frequency high rate sound transmission zone. In the frequency range of 1500Hz–6300Hz, it is high frequency resonant sound absorption. It is found that PTFE as a fine sound transmission material as well as a fine sound absorption material. The original test provides a solid evidence for further research and modeling of sound transmission theory.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"169 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114952464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nanoindentation response and microstructure of single-crystal silicon under different loads","authors":"Woei-Shyan Lee, Tao-Hsing Chen, Shuo-Ling Chang","doi":"10.1109/NANOMED.2009.5559094","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559094","url":null,"abstract":"Nanoindentation tests are performed on single-crystal silicon wafers using a Berkovich indenter and maximum indentation loads of 30 mN, 40 mN, and 70 mN, respectively. The microstructural evolutions of the indented specimens are examined using transmission electron microscopy and selected area diffraction techniques. The results show that the unloading curve of the specimen indented to a maximum load of 30 mN has a smooth profile, whereas those of the specimens indented to 40 mN or 70 mN have a pop-out feature. The hardness and Young's modulus of the silicon specimens reduce with an increasing indentation load, and have values of 15.8 GPa and 182 GPa, respectively, under the highest indentation load of 70 mN. A completely amorphous phase is induced within the indentation zone in the specimen indented to a maximum load of 30 mN, whereas a mixed structure comprising amorphous phase and nanocrystalline phase is found in the indentation zones in the specimens loaded to 40 mN and 70 mN, respectively.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123616693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of Blood Pressure using magnetic method of blood pulse acquisition","authors":"C. T. Phua, G. Lissorgues","doi":"10.1109/NANOMED.2009.5559106","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559106","url":null,"abstract":"Current cuffless method of Arterial Blood Pressure (ABP) measurements can be continuously calculated from pulse wave velocity and the Pulse Transit Time (PTT). PTT is usually recorded as the time delay from the R wave of Electrocardiographic (ECG) signal to the upstroke of a peripheral pulse wave signal measured using Photoplethysmographic (PPG) sensors or alternatively from the sound of Phonocardiographic (PCG) signal. This paper proposes an alternative novel method of measuring the magnetic disturbance, using a Giant-Magneto-Resistance (GMR) based sensor, created by blood flow in a uniform magnetic field for peripheral pulse wave signal measurements allowing an optical independent measurement system for ABP. The magnetic disturbance created by blood flow in a uniform magnetic field allows for the sensing of the peripheral pulse wave… Measurements were done on 10 subjects aged between 22 to 25 years old where the ABP measured using the PTT correlates well within 8% error with respect to the Mean Arterial blood Pressure (MAP) measured from commercially available cuff based automated ABP measurement devices.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125042276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Brandon Bartling, Lei Fang, Lawrence Chao-Shan Chou, Lu Li, Shih-Hong Chang, B. Hwang, C. Liu
{"title":"Development of nano-metallic catalysts for the single-use, disposable biomedical sensor platform technology","authors":"Brandon Bartling, Lei Fang, Lawrence Chao-Shan Chou, Lu Li, Shih-Hong Chang, B. Hwang, C. Liu","doi":"10.1109/NANOMED.2009.5559074","DOIUrl":"https://doi.org/10.1109/NANOMED.2009.5559074","url":null,"abstract":"Single use, disposable biosensors for the in vitro detection of biomarkers are important for home care, point-of-care and early stage diagnosis applications. The sensitivity and the repeatability of the biosensor outputs are important, and minimum interference by other components in the test medium is also essential. Enzymatic reactions of the biomarkers producing an electrochemically active species, such as H2O2 and NADH, are often used as a means for the detection of the biomarkers. Nanoparticle metallic catalyst appears to provide enhanced performance of various biosensors. Experimental assessments of many biomarkers, such as glucose, ketone (3β-hydroxybutyrate), total bile acid and others using the nano-particle metallic catalyst have been undertaken. It is also shown that bi-metallic nanoparticles can further enhance the performance of the biosensor. Methods of preparing and testing these of nano-particles will be discussed.","PeriodicalId":289461,"journal":{"name":"2009 IEEE 3rd International Conference on Nano/Molecular Medicine and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129423068","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}