Wind storms in Britain (BT power systems) 英国的暴风雨(英国电信电力系统)
12th International Conference on Telecommunications Energy Pub Date : 1990-10-21 DOI: 10.1109/INTLEC.1990.171217
J. Coppinger
{"title":"Wind storms in Britain (BT power systems)","authors":"J. Coppinger","doi":"10.1109/INTLEC.1990.171217","DOIUrl":"https://doi.org/10.1109/INTLEC.1990.171217","url":null,"abstract":"Two hurricane-force storms in the past three years have severely tested the British Telecom UK network. The task of restoring telecommunications service presented huge challenges in the deployment of staff equipment and materials. Experience was gained about both systems and procedures and, in particular, the importance of remote alarm, interrogation, and control facilities. The author describes the extent of the disruption and deals mainly with the performance of telecommunications power systems, the lessons learned and plans for closer integration of network power and building services within the network operations unit.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117346642","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A system approach assures quality battery plant performance 系统的方法保证了电池工厂的高质量性能
12th International Conference on Telecommunications Energy Pub Date : 1990-10-21 DOI: 10.1109/INTLEC.1990.171235
R. Kakalec
{"title":"A system approach assures quality battery plant performance","authors":"R. Kakalec","doi":"10.1109/INTLEC.1990.171235","DOIUrl":"https://doi.org/10.1109/INTLEC.1990.171235","url":null,"abstract":"The design of a telephone central office telecommunication battery plant is discussed with an emphasis on the critical processes required to insure a quality performing battery plant-thorough and complete requirements, design considerations, and system integration testing. Two perspectives of a quality battery plant are presented-the vendor's and the user's.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116943942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A new uninterruptible power supply with a bidirectional cycloconverter 一种新型双向循环变换器不间断电源
12th International Conference on Telecommunications Energy Pub Date : 1990-10-21 DOI: 10.1109/INTLEC.1990.171281
T. Aoki, K. Yotsumoto, S. Muroyama, Y. Kenmochi
{"title":"A new uninterruptible power supply with a bidirectional cycloconverter","authors":"T. Aoki, K. Yotsumoto, S. Muroyama, Y. Kenmochi","doi":"10.1109/INTLEC.1990.171281","DOIUrl":"https://doi.org/10.1109/INTLEC.1990.171281","url":null,"abstract":"A new configuration and control mechanism for an uninterruptible power supply (UPS) with a bidirectional cycloconverter are described. When commercial AC power is operating normally, the load is supplied by commercial AC power and the bidirectional cycloconverter operates as a battery charger. During interruptions of commercial AC power, the bidirectional cycloconverter operates as an inverter and supplies AC power to the load. Unlike conventional UPS, this new configuration does not require a battery charger, so it can be small, light-weight, cost-effective, and highly efficient. The output characteristics during the commercial AC power interruptions are also discussed.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126937236","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Power and backup power considerations for the ISDN network termination 1 (NT1) ISDN网络终端1 (NT1)的电源和备用电源考虑
12th International Conference on Telecommunications Energy Pub Date : 1990-10-21 DOI: 10.1109/INTLEC.1990.171219
K. Mistry, K. Moisan, T. D. O'sullivan
{"title":"Power and backup power considerations for the ISDN network termination 1 (NT1)","authors":"K. Mistry, K. Moisan, T. D. O'sullivan","doi":"10.1109/INTLEC.1990.171219","DOIUrl":"https://doi.org/10.1109/INTLEC.1990.171219","url":null,"abstract":"The evolution to a narrowband integrated services digital network (ISDN) necessitates the installation of additional electronics at the user end of the loop. Providing power and backup power for these electronics (referred to as the network termination 1 (NT1)) offers challenges to designers. One problem is that reliability and backup powering are not currently addressed in a uniform manner in the US. For locally provided power, the authors propose baseline criteria for reliability and backup powering. One generic topology comprising a power supply, a battery charger, and secondary batteries is presented. A backup time of eight hours is proposed with an option for additional backup provided via an extended reserve cabinet using primary or secondary batteries.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130007700","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
New PWM converter circuits combining zero switching loss with low conduction loss 零开关损耗与低导通损耗相结合的新型PWM变换器电路
12th International Conference on Telecommunications Energy Pub Date : 1990-10-01 DOI: 10.1109/INTLEC.1990.171245
P. Imbertson, N. Mohan
{"title":"New PWM converter circuits combining zero switching loss with low conduction loss","authors":"P. Imbertson, N. Mohan","doi":"10.1109/INTLEC.1990.171245","DOIUrl":"https://doi.org/10.1109/INTLEC.1990.171245","url":null,"abstract":"A new PWM (pulse width modulation) technique is presented and applied to two DC-DC power converters. The new converter topologies completely eliminate switching losses while retaining the low conduction losses typical of PWM circuits. The switches are operated for differing lengths of time, i.e., with unbalanced or asymmetrical duty cycles (for example, one switch at 40% and the other at 60%). The deadtime between switch conduction intervals is made long enough to insure that the switch voltages have commutated naturally from rail to rail, but not so long that the switch voltages have begun their return trip along their oscillatory path between the input rails. Thus, the best features of resonant (zero switching loss) and PWM (low conduction loss) circuits are combined. Design equations and notes are included for a buck type (step-down) and a boost type (step-up) converter.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1990-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123436764","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×