Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen最新文献

筛选
英文 中文
Noise Characterization in Digital Holographic Microscopy with Partial Spatial Coherence Illumination 部分空间相干照明下数字全息显微镜的噪声表征
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.ITH1E.4
J. Dohet-Eraly, C. Yourassowsky, A. E. Mallahi, F. Dubois
{"title":"Noise Characterization in Digital Holographic Microscopy with Partial Spatial Coherence Illumination","authors":"J. Dohet-Eraly, C. Yourassowsky, A. E. Mallahi, F. Dubois","doi":"10.1364/ISA.2017.ITH1E.4","DOIUrl":"https://doi.org/10.1364/ISA.2017.ITH1E.4","url":null,"abstract":"We present a theoretical model, experimentally validated, characterizing the noise when partial spatial coherence illumination is used in digital holographic microscopy. Both defocusing distance of the noise-generating field and spatial coherence of light are considered.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126891229","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quanta image sensors (QIS) for low-light high speed imaging 量子图像传感器(QIS)用于微光高速成像
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IM2E.3
E. Fossum
{"title":"Quanta image sensors (QIS) for low-light high speed imaging","authors":"E. Fossum","doi":"10.1364/ISA.2017.IM2E.3","DOIUrl":"https://doi.org/10.1364/ISA.2017.IM2E.3","url":null,"abstract":"Recent progress on the Quanta Image Sensor (QIS) is reported. A 1Mjot QIS operating at 1040 fps with 0.22e- rms read noise has been deomstrated in a 2-layer stacked backside-illuminated 65nm/45nm CMOS image sensor process.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123869159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Ultra-compact nanophotonic devices designed by computational metamaterials 计算超材料设计的超紧凑纳米光子器件
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IM2E.2
Apratim Majumder, B. Shen, R. Polson, R. Menon
{"title":"Ultra-compact nanophotonic devices designed by computational metamaterials","authors":"Apratim Majumder, B. Shen, R. Polson, R. Menon","doi":"10.1364/ISA.2017.IM2E.2","DOIUrl":"https://doi.org/10.1364/ISA.2017.IM2E.2","url":null,"abstract":"Computationally designed metamaterials are used to realize a number of novel nanophotonic devices. We report on the development of ultra-compact on-chip polarization rotators, waveguide cloaks and all optical modulators made possible by the use of a non-linear optimization algorithm.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"132 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121544861","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High-NA Chromatic-aberration-corrected Diffractive Lens for Broadband Focusing 用于宽带聚焦的高na色差校正衍射透镜
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IW3E.4
Xiaowen Wan, R. Menon
{"title":"High-NA Chromatic-aberration-corrected Diffractive Lens for Broadband Focusing","authors":"Xiaowen Wan, R. Menon","doi":"10.1364/ISA.2017.IW3E.4","DOIUrl":"https://doi.org/10.1364/ISA.2017.IW3E.4","url":null,"abstract":"Replacing bulky refractive lenses, a planar high-NA diffractive-lens is demonstrated to achieve apochromatic broadband focusing. For three-wavelength illumination (450nm, 538nm and 610nm), an average focusing efficiency of 66.6% is achieved with far-field-diffraction limited focal spots.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"190 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115893770","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Hyperspectral Compressive Sensing based on Online Dictionary Learning 基于在线词典学习的高光谱压缩感知
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.ITH4E.1
Irem Ülkü, Ersin Kızgut
{"title":"Hyperspectral Compressive Sensing based on Online Dictionary Learning","authors":"Irem Ülkü, Ersin Kızgut","doi":"10.1364/ISA.2017.ITH4E.1","DOIUrl":"https://doi.org/10.1364/ISA.2017.ITH4E.1","url":null,"abstract":"This is the first time that blind compressive sensing (BCS) is used with online dictionary learning in hyperspectral image compression. BCS is among the best three algorithms in terms of compression performance at high ratios.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124711698","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Blood flow monitoring of exercising muscle with fast diffuse correlation spectroscopy: a pilot study 用快速漫射相关光谱法监测运动肌肉的血流:一项初步研究
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.ITU4E.2
Wan Detian, W. Baker, A. Parthasarathy, Zhu Liguo, Zeren Li, A. Yodh
{"title":"Blood flow monitoring of exercising muscle with fast diffuse correlation spectroscopy: a pilot study","authors":"Wan Detian, W. Baker, A. Parthasarathy, Zhu Liguo, Zeren Li, A. Yodh","doi":"10.1364/ISA.2017.ITU4E.2","DOIUrl":"https://doi.org/10.1364/ISA.2017.ITU4E.2","url":null,"abstract":"Blood flow monitoring during rhythm exercising is very important for sports medicine and muscle dieases. Diffuse correlation spectroscopy(DCS) is a relative new invasive way to monitor blood flow but suffering from muscle fiber motion. In this study we focus on how to remove exercise driven artifacts and obtain accurate estimates of the increase in blood flow from exercise. Using a novel fast software correlator, we measured blood flow in forearm flexor muscles of N=2 healthy adults during handgrip exercise, at a sampling rate of 20 Hz. Combining the blood flow and acceleration data, we resolved the motion artifact in the DCS signal induced by muscle fiber motion, and isolated the blood flow component of the signal from the motion artifact. The results show that muscle fiber motion strongly affects the DCS signal, and if not accounted for, will result in an overestimate of blood flow more than ~1000%. Our measurements indicate rapid dilation of arterioles following exercise onset, which enabled blood flow to increase to a plateau of ~200% in ~10s. The blood flow also rapidly recovered to baseline following exercise in ~10s. Finally, preliminary results on the dependence of blood flow from exercise intensity changes will be discussed.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130085453","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Simplified wide-angle lens corrected using a projection technique 使用投影技术校正的简化广角镜头
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IW3E.1
X. Dallaire, S. Thibault
{"title":"Simplified wide-angle lens corrected using a projection technique","authors":"X. Dallaire, S. Thibault","doi":"10.1364/ISA.2017.IW3E.1","DOIUrl":"https://doi.org/10.1364/ISA.2017.IW3E.1","url":null,"abstract":"Plenoptic imaging can be used to correct aberrations. However, current techniques are demanding on computing power and limit themselves to systems with small field of view. We present a simplified correction technique well adapted to wide-angle lens. We then present simulation and experimental results carried on a custom simple wide-angle lens.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132258763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Broadband Imaging Through an Omni-Resonant Optical Micro-Cavity 全共振光学微腔的宽带成像
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IW4E.3
S. Shabahang, H. Kondakci, Massimo L. Villinger, Joshua D. Perlstein, A. Elhalawany, A. Abouraddy
{"title":"Broadband Imaging Through an Omni-Resonant Optical Micro-Cavity","authors":"S. Shabahang, H. Kondakci, Massimo L. Villinger, Joshua D. Perlstein, A. Elhalawany, A. Abouraddy","doi":"10.1364/ISA.2017.IW4E.3","DOIUrl":"https://doi.org/10.1364/ISA.2017.IW4E.3","url":null,"abstract":"We demonstrate broadband imaging through an optical micro-cavity in which omni-resonance is achieved by angularly-multiplexed phase-matching. We create a 60-nm-wide spectral transmission window starting from 0.7-nm-wide resonances.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125365933","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Computational Cannula Microscopy: Fluorescent imaging through ultra-thin glass needle 计算机套管显微镜:通过超薄玻璃针进行荧光成像
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.ITH1E.2
Ganghun Kim, N. Nagarajan, E. Pastuzyn, Kyle R Jenks, M. Capecchi, J. Shepherd, R. Menon
{"title":"Computational Cannula Microscopy: Fluorescent imaging through ultra-thin glass needle","authors":"Ganghun Kim, N. Nagarajan, E. Pastuzyn, Kyle R Jenks, M. Capecchi, J. Shepherd, R. Menon","doi":"10.1364/ISA.2017.ITH1E.2","DOIUrl":"https://doi.org/10.1364/ISA.2017.ITH1E.2","url":null,"abstract":"We demonstrate a fluorescent microscopy through an optical cannula (220µm diameter glass needle) for deep tissue imaging. We first show sample images captured in thin sections for the proof of principle. Then cannula is inserted deep into dissected brain tissue which captured high resolution images of microglia cells.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115051596","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Materials degrees of freedom for optical design 光学设计的材料自由度
Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen Pub Date : 2017-06-26 DOI: 10.1364/ISA.2017.IW3E.3
O. Tzang, Anurag Agrawal, R. Piestun
{"title":"Materials degrees of freedom for optical design","authors":"O. Tzang, Anurag Agrawal, R. Piestun","doi":"10.1364/ISA.2017.IW3E.3","DOIUrl":"https://doi.org/10.1364/ISA.2017.IW3E.3","url":null,"abstract":"We present a new concept for the design of optical elements. By specifying a general material with tailored anisotropic refractive index, we design refractive lenses that focus light with diffraction-limited resolution and reduced aberrations.","PeriodicalId":263258,"journal":{"name":"Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114072562","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信