2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)最新文献

筛选
英文 中文
The optimal design of lighting systems for designated office building in Thailand according to ministerial, the Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E.2552 泰国指定办公大楼照明系统的优化设计,根据部委,建筑类型或大小标准和规则和程序,建筑节能设计,法案B.E.2552
S. Panjavaranont, P. Bhasaputra, W. Pattaraprakorn, K. Tirawannavit, C. Kumpeerakupt, S. Rimsmutchai, N. Pawanawichien
{"title":"The optimal design of lighting systems for designated office building in Thailand according to ministerial, the Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E.2552","authors":"S. Panjavaranont, P. Bhasaputra, W. Pattaraprakorn, K. Tirawannavit, C. Kumpeerakupt, S. Rimsmutchai, N. Pawanawichien","doi":"10.1109/ICUEPES.2011.6497773","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497773","url":null,"abstract":"The financial index of payback period analysis is proposed to evaluate the economic performance of lighting system between conventional designs and design by the Energy Conversation Promotion Act (no.2) B.E. 2550 of Ministry of Energy, The Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E.2552 for office building in term of illumination standard, energy consumption, return of investment and environmental aspect. First of all, the Type or Size of Building Standards and Rule and Procedures, Building Design for Energy Conservation, Act B.E.2552 is reviewed to compare with the conventional designs of lighting system for office building. Secondary, the life time energy consumption of fluorescent lamp T5 with electronic ballast, fluorescent lamp T8 with standard ballast and fluorescent lamp T8 with electronic ballast is simulated by various sizes of office buildings according to IEEE, IEC, IES, and the Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E.2552. In addition, the payback period and CO2 emission of lighting system for selected office building are simulated by various scenarios which the analytical results show that are the optimal lighting system for office building under the present situation. Finally, the optimal design of lighting system for designated office building in Thailand will be discussed about the energy performance with environmental friendly.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128794278","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Electricity generation from micro hydro turbine: A case study of crossflow turbine 微型水轮机发电:以横流水轮机为例
Y. Keawsuntia
{"title":"Electricity generation from micro hydro turbine: A case study of crossflow turbine","authors":"Y. Keawsuntia","doi":"10.1109/ICUEPES.2011.6497731","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497731","url":null,"abstract":"From the energy crisis situation in the present, renewable energy becomes the main choice of national energy. Hydropower is a renewable energy as very clean source energy. Especially small hydropower, the renewable energy which still has large potential and low cost of installation. Micro hydro turbine is an alternative technology for electricity generating that does not cause pollution from small hydropower. The crossflow turbine was studied experimentally in this project because of it is low cost, small sized, the materials used in construction are cheap and the technologies involved are conventional. At testing of micro crossflow turbine with 0.6 meter diameters of wheel and a 20 blades water turbine which has a semi-circle shape at 0.1 meter diameters of blade, connected with generator at gear up ratio of 1-3 and 1-5 respectively, was undertaken. The results from the test run of crossflow turbine by varying flow rate from 60 to 120 L/min at 0.0127, 0.0190 and 0.0254 meter diameter of nozzle respectively, showed that at water flow rate 120 L/min, 0.017 meter diameter of nozzle and gear ratio of 1-3 give the maximum electric power of 121 watts at generator speed of 468 rpm.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127165882","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
VHDL implementation for measurement of the distance test distribution pattern of the Tri-Axial magnetic probe for the PD detection circuit system by using 3 GHz ADC and FPGA 用VHDL实现了用于PD检测电路系统的三轴磁探头距离测试分布模式的测量,采用3ghz ADC和FPGA
E. Emilliano, C. Chakrabarty, A. Ghani, A. Ramasamy
{"title":"VHDL implementation for measurement of the distance test distribution pattern of the Tri-Axial magnetic probe for the PD detection circuit system by using 3 GHz ADC and FPGA","authors":"E. Emilliano, C. Chakrabarty, A. Ghani, A. Ramasamy","doi":"10.1109/ICUEPES.2011.6497711","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497711","url":null,"abstract":"This paper is purely a model to implement Partial Discharge (PD) detection in FPGA technology and then implement the VHDL modeled in FPGA technology for measurement of the distance test distribution pattern of the Tri-Axial magnetic probe using 3GHz ADC (ADC083000RB-Reference Board) and impulse generator. Partial discharge (PD) is a well known phenomenon that causes insulation degradation in cross linked polyethylene (XLPE) power cable and ultimately it will cause insulation failure. The research shall involve ISE Simulator version 10.1i (Xilinx) and ISE Xilinx Synthesized Technology (XST) using Very high integrated circuit Hardware Description Language (VHDL) programming to evaluate the use of Field Programming Gate Array (FPGA-Xilinx Virtex 5 ML501 Board) for the detection and counting of partial discharge signals in high voltage underground cable. The impulse signals at the input data have very fast rise time in the field can have a bandwith of about 200 - 600 MHz. The output signals of the combination 4 blocks (peak detector block, 64 bit BCD counter with reset block, reset automatic block and 64 bit BCD counter) is processed using reset automatic block and 64 bit latch block for keep output data in LCD to constant when the 64 bit BCD counter block is reset and return to zero again until update new data again. The combination of all blocks of PD detection circuit system is tested by using Xilinx ISE simulator and implemented by ISE Xilinx Synthesized Technology and Xilinx ISE Implement Design. The distance resolution measurement of magnetic field is shown in this paper.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125204904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Accelerated starting by motoring a grid-connected small wind turbine generator 通过驱动并网的小型风力涡轮发电机加速启动
M. Aner, E. Nowicki, D. Wood
{"title":"Accelerated starting by motoring a grid-connected small wind turbine generator","authors":"M. Aner, E. Nowicki, D. Wood","doi":"10.1109/ICUEPES.2011.6497765","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497765","url":null,"abstract":"In recent years, an increasing proportion of small wind turbines have been connected to the electrical grid. With appropriate switchgear and control, it should be possible to use grid power to operate the generator as a motor for faster starting of the turbine. The artificial case of a step increase in wind speed from zero is considered. It is shown that motoring yields an energy gain for all wind speeds typical of the operating range of small turbines. This paper proposes short-period motoring of a permanent magnet generator in a 5kW wind turbine system connected to the grid with a backward very sparse matrix converter which has bidirectional power flow capability. Motoring produces torque in the same direction as the aerodynamic torque on the turbine which in turn accelerates the turbine more quickly towards the maximum power point. Interestingly, the overall result is that more energy is delivered to the grid by short-term motoring than in the case where the turbine is accelerated aerodynamically without motoring. In the proposed system, the very sparse matrix converter controls the generator torque through field orientation where d-axis current is set to zero while the q-axis current is used to control the generator torque and thus control the turbine speed in both motoring and generating modes. The switching signals of the converter are formed based on the principle of space vector modulation. Simulation results, with and without an electromagnetic starting torque, indicate that the proposed technique increases the overall energy efficiency of small wind turbine systems while providing fast starting.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116600129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
GIS based distribution load flow for better planning and operation 基于GIS的配电潮流更好的规划和运行
K. Buayai, W. Ongsakul, M. Nadarajah, K. Pauirnchai
{"title":"GIS based distribution load flow for better planning and operation","authors":"K. Buayai, W. Ongsakul, M. Nadarajah, K. Pauirnchai","doi":"10.1109/ICUEPES.2011.6497717","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497717","url":null,"abstract":"This paper presents the conceptual design of the novel integrated planning tool intended to distribution system load flow based on GIS and it application. The computer-based (PC) framework combines the analytical capabilities of modern Geographic Information Systems (GIS) and distribution load flow. The avenue program is the program language that comes with Arc View. It used for tracing the attributes of distribution feeder perform to load flow input data. The load flow analysis was implemented in MATLAB and embedded in a GIS application (Arc View). This GIS like drawing tool has the capability to partially display a system based on different layers. The processing capabilities of GIS and the system' ability to manipulate geo-referenced data and results in different formats and models make them suitable for planning and operation of distribution system. Multiple agents are involved in the distribution system planning and operation and therefore, authorities, utilities, and investors can become users of GIS planning.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130044904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Energy audit of a 400/220 kV substation - A case study 400/220千伏变电站能源审计案例研究
S. M. Jaralikar, M. Aruna
{"title":"Energy audit of a 400/220 kV substation - A case study","authors":"S. M. Jaralikar, M. Aruna","doi":"10.1109/ICUEPES.2011.6497772","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497772","url":null,"abstract":"The paper highlights the necessity of undertaking performance analysis and energy audit study of an electrical installation, more particularly a power substation on regular basis. A 630 MVA, 400/220 kV substation was identified and a detailed study was carried out to assess the various station performance parameters under different operating conditions. It was observed that the installed capacity of the station (transformer) was very large compared to the actual load it had to supply. Thus the station was under loaded and underutilized for the major period of its operation. This reduced the operational efficiency of the station. Secondly the incoming line voltage level was remaining high during most of the period of operation. Presently voltage is tried to be maintained by switching ON the line reactors at the receiving and sending ends of this station, switching OFF one of the 400 kV incoming lines during off peak loading conditions, thus risking the supply reliability. The present study emphasizes on the urgent need for improving the power quality, streamlining and optimizing the station capacity, operations and its loading pattern. Accordingly suggestions are proposed for the same.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116636143","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Design and simulation of active antenna for communication in smart grids 智能电网通信有源天线的设计与仿真
V. K. Sharma, H. Kumar, M. Sharma
{"title":"Design and simulation of active antenna for communication in smart grids","authors":"V. K. Sharma, H. Kumar, M. Sharma","doi":"10.1109/ICUEPES.2011.6497753","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497753","url":null,"abstract":"In this paper, the design of a dual-port dual-band annular slot active antenna suitable for communication use in smart grids & WLAN, a new active antenna is proposed for optimizing the smart grid. Two way commutations are key to making the grid smarter. The smart grids refer to system that can communicate data back and forth between a utility company and a customer. The wireless communication and antennas that utilize RF signals are often best suited to facilitate this grids communication. This antenna based on modern MIC and MMIC fabrication technology is used to develop a compact light weight, small size, high performance and low cost active antenna. The proposed antenna is designed to radiate and transmit equal amounts of power. The return loss of the proposed antenna is higher than that desired for one-port antenna application at the desired dual-band frequencies. The antenna generates two separate frequency resonant modes cover to cover 2.45/5.2Ghz. The antenna is fabricated on one side of a Neltec substrate with εr =3.2 and thickness= 0.762 mm, and the microstrip feeding line is fabricated on the opposite side of the board. The antenna is designed to operate at WLAN bands centered at 2.45 and 5.2GHz. The simulated and measured results show fairly good agreement.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121769669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Thermal performance enhancement in solar air heater channel with periodically V-shaped baffles 带有周期性v型挡板的太阳能空气加热器通道的热性能增强
C. Khanoknaiyakarn, S. Kwankaomeng, P. Promvonge
{"title":"Thermal performance enhancement in solar air heater channel with periodically V-shaped baffles","authors":"C. Khanoknaiyakarn, S. Kwankaomeng, P. Promvonge","doi":"10.1109/ICUEPES.2011.6497777","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497777","url":null,"abstract":"The research paper presents a study on thermal performance enhancement in a rectangular channel heat exchanger mounted with periodically V-shaped baffles. The channel has an aspect ratio (width to height ratio), AR=10 and height, H=30 mm while baffle characteristics are the baffle to channel height ratio, e/H=0.2, 0.3 and 0.4; the baffle pitch to channel height ratio, PR=P/H=2 and 2.67; the attack angle (α) of 30° relative to the flow direction. The experiment has been conducted by varying air flow velocity in order to adjust Reynolds number range from 5000 to 25,000. The upper wall of the channel is uniformly heated as a constant heat flux while the rests are covered with thermal insulations to reduce heat loss to surroundings. The effects of the baffles on Nusselt number and friction factor have been examined. The overall performance of tested baffled channel is evaluated to obtain the degree of heat transfer enhancement and friction factor induced by baffles with respect to the smooth channel under similar flow conditions.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128883307","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
Water valuation in Vietnamese electric power generation market 越南发电市场用水估价
D. X. Duc, J. G. Singh, W. Ongsakul
{"title":"Water valuation in Vietnamese electric power generation market","authors":"D. X. Duc, J. G. Singh, W. Ongsakul","doi":"10.1109/ICUEPES.2011.6497713","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497713","url":null,"abstract":"This work has been devoted to water valuation regarding Vietnamese reservoirs in a competitive electricity market environment. Water value concept, which has been assumed as fuel cost of water, helped to reflect the exploiting cost of water resource in the context of hydrothermal power system. In this work, the Stochastic Dual Dynamic Programming (SDDP) approach has been suggested for modeling the water valuation problem. Further, a trade-off has been obtained between immediate and future operating cost. Effectiveness of the developed approach has been investigated in Vietnamese electric power generation market for the period of 2011-2012. The results have been obtained in terms of the water value for major reservoirs, short-run marginal cost (SRMC) and classification of generating units as well. Moreover, optimal generation scheduling of cascading reservoirs and their respective trajectories have also been analyzed in this work.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127898511","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A new approach for designing a hybrid solar concentrator 一种设计混合太阳能聚光器的新方法
J. Canaletti, C. Cristofari, G. Notton, J. Panighi
{"title":"A new approach for designing a hybrid solar concentrator","authors":"J. Canaletti, C. Cristofari, G. Notton, J. Panighi","doi":"10.1109/ICUEPES.2011.6497750","DOIUrl":"https://doi.org/10.1109/ICUEPES.2011.6497750","url":null,"abstract":"From a promising first study performed on a reflecting flats solar concentrator, we propose to improve and optimize the design by providing a number of additional functions related to technological progress in the field of energy solar and electrical engineering. In order to satisfy a need for a specific production of heat around 150°C, the original system is equipped with an anti-radiation structure boiler and a more efficient control to improve and regulate the production of heat. Taking advantage of these technical improvements, photovoltaic cells are added behind flats for a stand-alone function and a possible connection to the grid (Fig 1). This new approach of solar concentration with hybrid PV/Th is studied with an experimental system built in our research laboratory.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114475060","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信