{"title":"Analysis and simulation of series-resonant high-frequency AC-linked DC-AC converter realizable by inverter modules","authors":"Jin Wei, M. Ishida, T. Hori","doi":"10.1109/PCCON.1997.638335","DOIUrl":"https://doi.org/10.1109/PCCON.1997.638335","url":null,"abstract":"This paper proposes a new-type series resonant high-frequency AC linked DC-AC converter which simplifies the connection of a cycloconverter part using inverter configuration. Different aspects and the same aspects between the conventional and the proposed converter are compared. A simplified discrete time model is proposed for the simulation and analysis of the transient and steady state performance of the proposed converter. Simulation results are validated by experimental results.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129642079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of single phase diode rectifiers with power factor correction circuits","authors":"A. Ueda, T. Shinohara, M. Matsubara, A. To","doi":"10.1109/PCCON.1997.638366","DOIUrl":"https://doi.org/10.1109/PCCON.1997.638366","url":null,"abstract":"Single phase diode rectifiers with single switch boost chopper and their variation of soft switching circuits are analyzed. It is found that the voltage fluctuation at an AC filter capacitor is not so small that it can be neglected. Then an analytical calculation method is developed with the consideration of the voltage fluctuation at the AC filter capacitor. The developed method is very useful for circuit design of high power factor converters.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130651988","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sensorless speed estimation based on primary and secondary resistance estimation and output voltage compensation of induction motor","authors":"K. Akatsu, A. Kawamura","doi":"10.1109/PCCON.1997.645589","DOIUrl":"https://doi.org/10.1109/PCCON.1997.645589","url":null,"abstract":"In the very low speed region, it is difficult to estimate the rotor speed of the induction motor, because the machine parameter (especially R/sub 2/) has strong influence on the speed estimation. It is known that the simultaneous estimation of the speed and R/sub 2/ is impossible. In this paper R/sub 2/ estimation is proposed in the transient state without adding any additional signal to the stator current, and the output voltage compensation without the voltage sensors. R/sub 1/ is estimated from the instantaneous reactive power.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133000657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A method to measure EMI due to electric field coupling on PCB","authors":"B. Pong, A.C.M. Lee","doi":"10.1109/PCCON.1997.638393","DOIUrl":"https://doi.org/10.1109/PCCON.1997.638393","url":null,"abstract":"A new method to measure electric field coupling between PCB copper traces is presented. This method enables measurement of noise from waveforms obtainable from breadboard prototypes, which is available in an early stage in the design process. The measurement result can then be analyzed and provide information for further PCB design. This method is verified by experiments and applied to an off-line flyback converter.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"31 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134289144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modified charge-control equation for more realistic simulation of power diode characteristics","authors":"K. Tseng, S. Pan","doi":"10.1109/PCCON.1997.645651","DOIUrl":"https://doi.org/10.1109/PCCON.1997.645651","url":null,"abstract":"The mathematical diode model currently used in most circuit simulations is not able to fully account for the device's forward and reverse recovery characteristics. This is due to the quasi-static diffusion charge equation and the fixed internal resistance used in the model. A proposed modification to the charge equation is presented in this paper. This important modification, together with a proposed charge-dependent internal resistance equation, have been test-implemented in PSpice using the Analog Behavioral Modeling technique. It has been experimentally verified that the new model is able to describe the power diode forward and reverse recovery behaviour more realistically without degrading the convergence properties of the simulators.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129444934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Digital robust speed servo system with complete avoidance of output saturation effect","authors":"Kiyoshi Ohishi, T. Mashimo, Nagaoka","doi":"10.1109/PCCON.1997.645662","DOIUrl":"https://doi.org/10.1109/PCCON.1997.645662","url":null,"abstract":"In order to prevent a robust speed servo system from having the saturation effect of controller output, this paper proposes a new anti-windup algorithm for a robust high-order speed controller connected to PI current controller in series. Using the proposed algorithm, a digital speed servo system completely avoids having the effect of output saturation caused by the limitation of motor voltage and motor current. The experimental results show that the proposed digital speed servo system has no output saturation effect caused by the limitation of motor voltage and motor current. The proposed system keeps the desired speed response for a fast and large speed reference on condition of full load torque.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129823246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A simple sensorless method for sinusoidal PWM converters","authors":"I. Ando, I. Takahashi, K. Utsunomiya","doi":"10.1109/PCCON.1997.645619","DOIUrl":"https://doi.org/10.1109/PCCON.1997.645619","url":null,"abstract":"This paper describes a simple sensorless method of PWM converters which can remove the line voltage sensors. It has the following characteristics. The voltage sensorless method is realized only by adding two operational amplifiers to the conventional PWM control circuit. Therefore, it has low cost and small size. The line current waveform can be improved by compensating voltage drops of the input filter reactor and dead-time of IGBTs. Quick response is also obtained on the high speed fluctuation of voltage and frequency or transient states. It can get characteristics other than the conventional complexity sensorless control methods. As a result, the input power factor and the total input current distortion of more than 99.5% and less than 2.3% are achieved, respectively on a 3 kW system. It not only obtains excellent performance but also realizes the small size, simple control construction and low cost converter.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"575 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132204308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Kanouda, Y. Sakurai, K. Kubo, K. Shimada, H. Kunisada, K. Umetsu
{"title":"All digital controlled three-phase UPS without inverter-transformer","authors":"A. Kanouda, Y. Sakurai, K. Kubo, K. Shimada, H. Kunisada, K. Umetsu","doi":"10.1109/PCCON.1997.638390","DOIUrl":"https://doi.org/10.1109/PCCON.1997.638390","url":null,"abstract":"A fully digital-controlled three-phase UPS (uninterruptible power system) is developed which does not have an inverter-transformer. To remove the transformer, a different type of main circuit from the conventional UPS is adopted. One phase of the input AC is regarded as the common voltage of the main circuit. A DC voltage stabilizer solves problems caused when this transformerless circuit is applied to the UPS. A digital controller with two RISC (Reduced Instruction Set Computer) processing microcomputers to operate the circuit is also proposed. Experiments show the THD (total harmonic distortion) of the input current is less than 5%, and that of the output voltage is less than 3.6% under nonlinear load.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133011522","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Harmonic evaluation of carrier-based PWM methods using harmonic distortion determining factor","authors":"S. Fukuda, K. Suzuki","doi":"10.1109/PCCON.1997.645622","DOIUrl":"https://doi.org/10.1109/PCCON.1997.645622","url":null,"abstract":"This paper describes harmonic evaluation of three phase carrier-based two-level and three-level PWM methods. The harmonic distortion determining factor, which represents the intrinsic spectral property of individual PWM methods, is used as the common basis. Almost all the carrier-based PWM schemes that have been proposed so far are considered. It is concluded that in AC drives the third harmonic injected sine PWM scheme is suitable for two-level inverters, and the double carrier unipolar PWM scheme is suitable for three-level inverters.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130150269","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J.M. Sun, N. Gamage, M. Nakaoka, H. Takano, T. Hatakeyama
{"title":"Comparative transient and steady-state performances of three resonant PWM inverter-controlled DC-DC converters using high-voltage transformer and cable parasitic circuit components","authors":"J.M. Sun, N. Gamage, M. Nakaoka, H. Takano, T. Hatakeyama","doi":"10.1109/PCCON.1997.638336","DOIUrl":"https://doi.org/10.1109/PCCON.1997.638336","url":null,"abstract":"The main purpose of this study is to describe some particular characteristic features and inherent benefits of series, parallel and series-parallel resonant tank inverter-fed DC-DC converters for a medical-use X-ray high-voltage generator from a practical viewpoint. The method to treat the parasitic resonant circuit parameters of the high-voltage high-frequency transformer used in three typical resonant tank topologies is discussed on the basis of some simulation results, and the simulation results are also verified by experiments.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114481917","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}