Soumyabrata Barik, D. Das, R. Bansal, R. Naidoo, N. Das
{"title":"A Novel Forward-Backward Zero Bus Power Flow Method for the Placement of Renewable DGs in Distribution Network","authors":"Soumyabrata Barik, D. Das, R. Bansal, R. Naidoo, N. Das","doi":"10.1109/AUPEC52110.2021.9597713","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597713","url":null,"abstract":"The zero bus power flow (ZBPF) method is a recent development in the field of operation of active distribution network with renewable distributed generations (RNDGs), where a certain percentage of the total real and reactive power load demand is imported from the main grid, and the rest of the load demand is supplied by the DGs. DG connected to the zero bus ensures the pre-specified energy exchange with the upstream grid and the distribution network. However, to adopt the idea the standard load flow should be changed due to the absence of a slack bus. In literature, Newton-Raphson load flow (NRLF) is available; however, NRLF will not be converged for the distribution networks where the ratio of resistance to inductance $left(frac{R}{X}right)$ is very high. To sort out this issue, a modified forward-backward based load flow is developed in this paper to consider the effect of zero bus and pre-specified energy exchange with the upstream grid. To determine the location of zero bus, locations and the sizes of DGs, and shunt capacitor, a multi-objective optimization problem (MOOP) is proposed here. The fuzzy maxmin principle (FMMP) based mixed discrete particle swarm optimization (MDPSO) is applied for the optimal placement of the RNDGs, and shunt capacitor in 33 bus DN.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123728283","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Chathuranga D.W. Wanninayaka Mudiyanselage, Hareesh Ravuru, Gauri M. Sankhe, K. Hasan
{"title":"Modelling and Operation of a Price-Signal Controlled Market-based Virtual Power Plant","authors":"Chathuranga D.W. Wanninayaka Mudiyanselage, Hareesh Ravuru, Gauri M. Sankhe, K. Hasan","doi":"10.1109/AUPEC52110.2021.9597697","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597697","url":null,"abstract":"The electricity grids are transforming due to the increased penetration of renewable energy sources and new types of loads. As a result, the operational and planning regimes of power grids are evolving, which requires new types of service options, technological responses, and management strategies. The virtual power plant (VPP) emerged in the electricity grid recently to tackle the grid challenges caused by the intermittent generation resources and subsequent market reforms as a VPP can inter-network a number of energy resources to act as a single energy resource. This paper proposes a method to implement a price-signal controlled market-based model of a VPP, which would be suitable to mimic a large commercial and industrial (C&I) customer equipped with flexible loads, solar PV, biofuel, and diesel generators. This study analyses the operation of a VPP with two VPP control algorithms based on the variation (i.e., very low and very high) of the electricity market price. The modified IEEE 9 bus network is used to develop and simulate the VPP model in MATPOWER, which is an open-source MATLAB based power system simulation package. The simulated results showcase the response of the VPP to the negative and high electricity spot price and how the control algorithm turn on/off its generator(s) and load units to gain the least operational cost for large C&I customer.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126652597","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Geethu Asokkumar Seena, C. Townsend, T. Fernando, H. Iu, Farzad Farajizadeh, Xinan Zhang
{"title":"A Review on Cascaded Multilevel Inverter Control Strategies","authors":"Geethu Asokkumar Seena, C. Townsend, T. Fernando, H. Iu, Farzad Farajizadeh, Xinan Zhang","doi":"10.1109/AUPEC52110.2021.9597740","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597740","url":null,"abstract":"Cascaded multilevel inverter topologies have gained a lot of interest in industry due to their modularity and scalability for high power and medium voltage levels. A set of structured controllers are required to coordinate each cell for achieving a broad variety of objectives. This paper presents a comprehensive overview of different control architectures developed for monitoring and coordinating cascaded multilevel inverters across a diverse set of applications.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126348322","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Islanded and Grid connected operation of PV based microgrid with HESS","authors":"E. Şehirli, Ö. Usta","doi":"10.1109/AUPEC52110.2021.9597790","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597790","url":null,"abstract":"In this paper, a micro grid study including photovoltaic (PV) array, super capacitor (SC) and lithium (Li)/Ion battery connected to grid by three phase neutral point clamped inverter (NPC) is realized for both islanded and grid connected mode operation. In this system, PV energy is transferred to dc bus by using SEPIC converter based MPPT having P&O algorithm. Also, each of Li/Ion battery and supercapacitors has bidirectional battery charger providing their charge and discharge. Besides, this bidirectional battery charger uses both current and voltage controllers for charging and discharging modes. Furthermore, there is also a supervisory controller providing the charge/discharge of battery and supercapacitor with respect to state of charge (SOC) of battery, supercapacitor and irradiation level of PV energy, availability of grid power. Moreover, this controller provides load shedding when there is no available power to supply for secondary loads. By using Matlab/Simulink, operation of the system is observed, with grid connected and island mode, under irradiation and ambient temperature change of the PV. Thanks to the simulation, PV power, battery and super capacitor power are presented. It is shown that the system presented here works properly and fast transients nearly few cycles are obtained between grid connected to islanded mode and vice versa. Also, THD of phase currents and voltages are obtained under the limit of standards.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124864652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Armin Abadifard, Pedram Ghavidel, S. Hosseini, Masoud Farhadi
{"title":"Non-Isolated Single-Switch Zeta Based High-Step up DC-DC Converter with Coupled Inductor","authors":"Armin Abadifard, Pedram Ghavidel, S. Hosseini, Masoud Farhadi","doi":"10.1109/AUPEC52110.2021.9597786","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597786","url":null,"abstract":"In this paper, a non-isolated high step-up DC-DC converter has been proposed for renewable energy applications. The proposed structure converter has been derived from the fundamental Zeta converter, in both of which only a single switch is employed. The voltage gain ratio has considerably enhanced in this converter with the absence of using switched capacity. To magnify voltage gain of the converter, a coupled-inductor has adopted. Increase and decrease of gain by changing the ratio of coupled-inductor assist the duty cycle. The number of components is low in this structure. The operating principle and evaluation of the proposed converter, considering designing approaches for elements, are discussed in detail. To verify the feasibility of the proposed converter, simulation results have been provided and evaluated.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133514789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Yifan Xu, Fuyan Liu, Xinyi Lai, Min Yu, Xiaoyong Yang, F. Wen
{"title":"Comprehensive Method for Determining Transformer Decommissioning Life Considering Economic Life and Physical Life","authors":"Yifan Xu, Fuyan Liu, Xinyi Lai, Min Yu, Xiaoyong Yang, F. Wen","doi":"10.1109/AUPEC52110.2021.9597728","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597728","url":null,"abstract":"Accurately calculating the decommissioning life of power transformers is not only helpful for maintaining their operational security and reliability, but also can enhance the economic operation of the power system concerned. This paper proposes a comprehensive method to determine the decommissioning life of power transformers considering both the economic life and physical life. First, according to the Life Cycle Cost (LCC) model of power transformers, a mathematical model of initial cost, operating and maintenance cost, failure cost and disposal cost is established. Then the economic life of power transformers is obtained based on the annual average LCC curve. Secondly, the physical life of power transformers is calculated by first correcting the expected service life with the load factor, temperature factor and humidity factor, and then correcting it with the failure number during operation. Finally, the theoretical decommissioning life of power transformers is attained by comprehensively considering both the economic life and physical life.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129460520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Palak M., G. Revati, Md. Alamgir Hossain, A. Sheikh
{"title":"Deep Learning models for Smart Building Load Profile Prediction","authors":"Palak M., G. Revati, Md. Alamgir Hossain, A. Sheikh","doi":"10.1109/AUPEC52110.2021.9597700","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597700","url":null,"abstract":"With the development in the sector of smart cities, smart buildings are becoming quite popular. For effective energy management of smart buildings, the accurate prediction of the electrical consumption data is required. To increase the accuracy of prediction, the paper proposes deep learning methods for load profile prediction in a model-free environment. In this paper, a commercial smart building load profile is predicted using the re-current neural network (RNN), long short term memory (LSTM), bidirectional LSTM (BiLSTM), and gated recurrent unit (GRU) model. Using the best features of RNN and BiLSTM a hybrid model is developed for the load profile prediction. To compare the performance of different models error metrics such as Root Mean Square Error (RMSE) and Mean Absolute Percentage Error (MAPE) are considered for performance evaluation. The paper also highlights the significance of hyperparameters in improving the accuracy of prediction. Finally, from the results, it can be claimed that the hybrid model performs better as compared to RNN, LSTM, and GRU models.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132999895","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Model Predictive Control for Cotton Farm Microgrid Systems in Australia","authors":"Yunfeng Lin, Jiangfeng Zhang, Li Li","doi":"10.1109/AUPEC52110.2021.9597774","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597774","url":null,"abstract":"This paper presents a model predictive control (MPC) approach to a microgrid at a cotton farm so as to minimize the water pumping operational cost while taking full advantage of renewable energy sources. The reason for using MPC is its ability in handling noise, disturbance, and real-time parameter changes. In this paper, the MPC models of grid-connected are established; moreover, the effectiveness and robustness of the MPC models are analyzed by cotton farm case studies. Simulation results show that the optimal MPC solutions for grid-connected microgrid of a farm are AU$8.4/ML less than a manual control-based strategy. In addition, the MPC solution shows outstanding robustness in controlling the water reservoir level. When the disturbance data of the rainy season in 2016 are added, the system saves 34.5% of the operating cost compared with the baseline. When the rainy season disturbance is added together, the system saves 11.74% of operating costs compared to the baseline.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134049390","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Speed Control of a DC-DC Buck Converter Fed DC Motor Using an Adaptive Backstepping Sliding Mode Control Approach","authors":"T. K. Roy, M. Pramanik, F. Faria, S. K. Ghosh","doi":"10.1109/AUPEC52110.2021.9597745","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597745","url":null,"abstract":"A nonlinear hybrid control approach is proposed in this paper to control the speed of a DC-DC buck converter driven DC motor. An adaptive backstepping sliding mode control theory is used to design the proposed controller. To handle the sudden load variation effects, the load torque is considered as unknown terms which will be estimated using an adaptation law. The theoretical stability of the system is ensured by using the Lyapunov theory. Finally, a simulation study is conducted to demonstrate the effectiveness of the proposed control scheme, and the performance is compared with an existing controller. Simulation results reveal that the proposed controller outperforms the existing controller in terms of overshoot and settling time.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"31 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134094189","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optimal Placement of SVC using Residue Technique and Coordination with PSS for Damping Inter-Area Oscillations","authors":"Chirag Rohit, K. Yadav, P. Darji","doi":"10.1109/AUPEC52110.2021.9597791","DOIUrl":"https://doi.org/10.1109/AUPEC52110.2021.9597791","url":null,"abstract":"Local mode and inter-area mode are slowly growing oscillations affects the stability of the power system significantly becasue such growing oscillations for long time may lead to the blackout of the system. The oscillatory mode instability occurs in the power system due to various reasons like fast-acting exciters with high gain, heavy power transfer over a weak transmission line, etc. In this paper, static var compensator (SVC) is used to improve the system stability and performance by providing damping to the low-frequency inter-area mode of oscillation. To provide damping effectively to such mode simultaneous tuning of SVC and power system stabilizer (PSS) is mendatory under the different operating conditions of the power system. Moreover, to achieve controllability in the power system, the flexible ac transmission systems (FACTS) device and the PSS should be located optimally. In this paper, a residue-based method has been used to find the optimal location of the SVC controller for damping of the inter-area mode of oscillations and the optimal location of PSS is determined by participation factors. The proposed method is implemented on Four-machine, Ten-bus, Two-area test system. Simulation studies have been carried out in MATLAB/Simulink platform to verify the performance of with and without SVC and PSS for the test systems under three operating conditions, i.e., light loading, nominal loading, heavy loading conditions. In addition to this, eigenvalue analysis and time-domain simulation results are used to evaluate the performance of the system under above three loading conditions. The results confirm that the proposed approach significantly enhances the stability of the inter-area oscillation mode under all loading conditions.","PeriodicalId":246799,"journal":{"name":"2021 31st Australasian Universities Power Engineering Conference (AUPEC)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123341101","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}