{"title":"Fractional order control for DC electrical drives in networked control systems","authors":"S. Coman, V. Comnac, C. Boldisor, D. Dumitrache","doi":"10.1109/OPTIM.2010.5510503","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510503","url":null,"abstract":"The distributed control systems with communication networks are used in many industrial applications. These systems are often referred as “Networked Control Systems” (NCS). The network's induced delays are inevitable, however, when data is transmitted between control devices. Network delays degrade the NCS performance and destabilize the system. The goal of the paper is to analyze the network delays influence over the system stability by using two DC electrical drives applications, one having a PI controller, the second an FPI (fractional PI) controller. The behaviors of the presented control systems have been examined with MATLAB/SIMULINK simulations. From here it results that the fractional controller increases the phase margin, hence improving stability.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"88 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126371025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improving and measuring the efficiency of the speed sensorless vector controlled induction motor","authors":"Emad A. Hussein, P. Mutschler","doi":"10.1109/OPTIM.2010.5510389","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510389","url":null,"abstract":"In this paper an accurate loss model-based controller to calculate the optimal air gap flux is proposed. The model includes copper losses, iron losses, harmonic losses, friction and windage losses, and stray losses. These losses are represented as a function of the air gap flux. By using the calculated optimal air gap flux compared with rated flux for speed sensorless indirect vector controlled induction motor, an improvement in motor efficiency and power factor is achieved especially at light load.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126385629","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Aurel Cornel Stanca, P. Borza, M. Romanca, R. Păun, S. Zamfir
{"title":"Model of supercapacitor-starter assembly used for internal combustion engines starting","authors":"Aurel Cornel Stanca, P. Borza, M. Romanca, R. Păun, S. Zamfir","doi":"10.1109/OPTIM.2010.5510526","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510526","url":null,"abstract":"The advantages of supercapacitors at the starting of internal combustion engines (ICE), as a complementary source to classical batteries, are nowadays certitudes: the significant extension of battery life span, the reduced volume and weight, meeting the environmental demands and lowering starting time and energy. The paper intends to develop a model of the electrical behavior of the assembly supercapacitor-starter driven by the ICE crankshaft, model allowing reasonable estimations of supercapacitors characteristics used for ICE starting. The development of the model was based on real signal analysis on a conventional battery-starter starting system.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115266781","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Toader, P. Ruset, S. Haragus, C. Blaj, I. Hategan, N. Pinte, I. Cata
{"title":"Selective detection of simple grounding faults in medium voltage power networks with resonant earthed neutral system","authors":"D. Toader, P. Ruset, S. Haragus, C. Blaj, I. Hategan, N. Pinte, I. Cata","doi":"10.1109/OPTIM.2010.5510512","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510512","url":null,"abstract":"In this paper the influence of the medium voltage lines insulation ageing on some network parameters, namely the capacitive zero-sequence impedance of the network, the zero-sequence impedance of the grounding and arc-suppression coils taken together, as well as the equivalent zero-sequence impedance as seen from the grounding fault location, is analyzed. As a result of the analysis useful criteria to selectively detect faulty lines during a single grounding fault are formulated. These criteria are implemented by a digital protection block BYCD - 2. Measurements done in a real medium voltage network, during purposely provoked faults, validate the concepts the block is based on.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115286877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Stirban, I. Boldea, G. Andreescu, D. Iles, F. Blaabjerg
{"title":"Motion sensorless control of BLDC PM motor with offline FEM info assisted state observer","authors":"A. Stirban, I. Boldea, G. Andreescu, D. Iles, F. Blaabjerg","doi":"10.1109/OPTIM.2010.5510439","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510439","url":null,"abstract":"This paper describes a new offline FEM assisted position and speed observer, for brushless dc (BLDC) PM motor drive sensorless control, based on the line-to-line PM flux linkage estimation. The zero-crossing of the line-to-line PM flux linkage occurs right in the middle of two commutation points, which is used as a basis for the position and speed observer. For performance applications, the position between commutation points is obtained by comparing the estimated line-to-line PM flux linkage with the FEM calculated line-to-line PM flux linkage. Even if the proposed observer relies on the fundamental model of the machine, a safe starting strategy under heavy load torque, called I-f control, is used, with seamless transition to the proposed sensorless control. The I-f starting method allows low-speed sensorless control, without knowing the initial position, and without machine parameters identification. Digital simulations and experimental results are shown, demonstrating the reliability of the FEM assisted position and speed observer for BLDC PM motor sensorless control operation.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"42 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121014685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improved contours for ToF cameras based on vicinity logic operations","authors":"G. Danciu, M. Ivanovici, V. Buzuloiu","doi":"10.1109/OPTIM.2010.5510428","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510428","url":null,"abstract":"In this article we propose an improved contour extraction approach for images acquired with a Time of Flight camera (ToF), by combining the information from the edges of the distance and luminance images. We define and use vicinity logic operations in order to extract a better contour that allows us to emphasize the objects of interest in the scene, and in the same time to eliminate the unuseful information, i.e. the “false” contours determined by noise, various textures, shadows etc. We present our results and draw the conclusions.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114292019","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement system for non-destructive testing using ultrasonic tomography spectral attenuation","authors":"G. Concu, Barbara de Nicolo, C. Piga, V. Popescu","doi":"10.1109/OPTIM.2010.5510507","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510507","url":null,"abstract":"This paper presents a measuring system and the automated measuring procedure for non-destructive diagnosis of stone masonry structures. The diagnosis is based on algorithms using the propagation times and the frequency centroid downshift of ultrasonic signals.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"264 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122543011","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Flux-based control of PMSM","authors":"M. Oettmeier, C. Heising, V. Staudt, A. Steimel","doi":"10.1109/OPTIM.2010.5510527","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510527","url":null,"abstract":"With increasing performance of magnet material and decreasing cost permanent magnet synchronous machines (PMSM) become more and more important for practical use in light railway and e-car applications. Excellent torque dynamics are extremely important in these applications - not because of acceleration or deceleration, but to meet additional demands as slip-slide protection and electronic stability control. Dynamics are limited by the rating and the switching frequency of the converter. Therefore, the control has to make optimal use of these limited resources. This paper presents a stator-flux based control scheme for PMSM which gives the maximum physically possible dynamics with regard to the limitations stated above. It bases on the indirect stator control (ISC) scheme for asynchronous machines and is similar to the virtual-grid-flux-based control of active front end converters (AFE). The simulation results presented are based on a simulation structure which is verified by measurement and simulation carried out at an AFE.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"121 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134327398","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of trace additives on dielectric properties of gas","authors":"Z. Kucerovsky, A. Ieta","doi":"10.1109/OPTIM.2010.5510351","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510351","url":null,"abstract":"Corona current is produced by interactions between an inhomogeneous electric field and gas. In this paper, the impact of the field on the gaseous medium is studied by measuring and analyzing voltage-current characteristics in several gas mixtures. As the work requires strict control of the medium, with mixture compositions guaranteed to ∼ 0.1 ppm, the corona is created in a special apparatus that facilitates medium handling. Gas chromatographic and spectroscopic techniques have been used to verify the results. It has been established that several trace concentrations of certain medium additives have a considerable impact on the magnitude of the corona current, and on the electrical dielectric properties and breakdown strength of the medium. Role of the additives in the corona medium is analyzed in terms of their chemical properties and their efficacy in suppressiong the breakdown. The additives, divided into groups according to their Milliken-Jaffe energy, are classified in terms of their impact on the corona current and breakdown.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133883581","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new conversion and control system for a small off - grid wind turbine","authors":"N. Muntean, O. Cornea, D. Petrila","doi":"10.1109/OPTIM.2010.5510367","DOIUrl":"https://doi.org/10.1109/OPTIM.2010.5510367","url":null,"abstract":"The paper proposes a new architecture for a small off-grid wind-power generation, control, and storage system. This system employs a wind turbine, power electronic converters, supercapacitors, and operates with a variable d.c. voltage in the intermediate d.c. circuit. A significant amount of the generated energy is used to warm water, as an additional storage capacity. Since the voltage across the supercapacitor changes as a measure of stored energy, a new class of power converters and their control has been proposed. An energy management strategy, specific to this scheme, has been implemented. The paper presents the overall design for the system, for power converters and the control strategy. Extensive simulation results are provided.","PeriodicalId":239366,"journal":{"name":"2010 12th International Conference on Optimization of Electrical and Electronic Equipment","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132087942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}