{"title":"Contextual effects on robotic experiments of sensory feedback for object manipulation","authors":"C. Stepp, B. Dellon, Y. Matsuoka","doi":"10.1109/BIOROB.2010.5627824","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5627824","url":null,"abstract":"Tactile and proprioceptive feedback for prosthetic hand users is assumed to be critical, yet there is no systematic knowledge about how to provide this feedback effectively. Haptic virtual environments are ideal tools with which to manipulate properties of object interaction to build a model of such feedback. This work shows the importance of the environmental context to capture results relevant to prosthetic hand sensory feedback. While an interface utilizing manipulation of a second-order oscillatory spring-mass system at its natural frequency did not show consistent effects of haptic feedback on motor performance, an interface based on manipulation of an object with the competing goals of overcoming friction without breaking the object showed an increase in task performance with the addition of haptic feedback to visual feedback. Contextual effects such as functional relevance should be considered in robotic experiments on the role of multisensory feedback in object manipulation.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123121368","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Baek, Yasuhide Kozuka, N. Sugita, A. Morita, S. Sora, R. Mochizuki, M. Mitsuishi
{"title":"Highly precise master-slave robot system for super micro surgery","authors":"Y. Baek, Yasuhide Kozuka, N. Sugita, A. Morita, S. Sora, R. Mochizuki, M. Mitsuishi","doi":"10.1109/BIOROB.2010.5625946","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5625946","url":null,"abstract":"Super micro surgery in neurosurgical field is very challenging problem because neurosurgeons handle very tiny object through a microscope. Advances in technology such as microscope make micro surgery possible, but manipulating small instruments under the circumstance of microscope restricts the humans' dexterity even in the constrained workspace. To perform micro surgery successfully, we have developed a master-slave surgical robot system. Our objective is to achieve the high accuracy of positioning and improving operability of micro surgery. In this paper, we address mainly mechanical design issues of slave manipulator and control system. We evaluated our system through suturing experiments with fine artificial blood vessels. The preliminary results show the improvement of surgeon's dexterity and operability.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121242969","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hiroshi Onodera, Takeshi Yamaguchi, Hiroteru Yamanouchi, Kazumasa Nagamori, Masaru Yano, Y. Hirata, K. Hokkirigawa
{"title":"Analysis of the slip-related falls and fall prevention with an intelligent shoe system","authors":"Hiroshi Onodera, Takeshi Yamaguchi, Hiroteru Yamanouchi, Kazumasa Nagamori, Masaru Yano, Y. Hirata, K. Hokkirigawa","doi":"10.1109/BIOROB.2010.5628030","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5628030","url":null,"abstract":"We studied a relationship between a zero moment point (ZMP) and a base of support (BOS) during slipping. ZMP is the point on the ground where no moment may be transmitted about the whole body center of mass (COM). When subjects could walk without slipping, ZMP was located within the BOS at a single support phase. When a fall after a forward slip was observed, the ZMP remained outside of the BOS edge. The maximum distance between the ZMP and the BOS edge (Lmax) was longer in the fall group than in the recovery group (p < 0.001). The maximum velocity of the slipping foot segment relative to the torso segment (vr max) had a positive correlation with Lmax. An intelligent shoe system, which can extend the shoe sole area (BOS) laterally, improved both static standing balance and dynamic standing balance. Thus, appropriate coefficient of sliding friction on the shoe sole and intelligent control of the shoe sole area would be of value in reducing the risk of falling, particularly for the people with movement disorders.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"235 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123300321","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An estimation method of muscle forces for each muscle group using theory of functionally different effective muscles considering human dynamics","authors":"Atsuki Sugino, S. Komada, J. Hirai","doi":"10.1109/BIOROB.2010.5628024","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5628024","url":null,"abstract":"Although the effectiveness of biofeedback using an electromyogram (EMG) has been reported, it is seldom used in ordinary therapeutic exercise because it takes time to attach electrodes. Conventional muscle force estimation methods using joint torque take time in order to solve optimization problems. In order to make the computation time shorter, a method has been proposed, which converts tip force of limbs to each force of 6 muscle groups by using the FEM theory for 2D motion of 2 joints of limbs, which is given to each optimization problem. Since muscles exert not only tip force of limbs but also force due to dynamics such as inertia force and so on, estimation accuracy is not satisfactory. The new tip force which is sum of tip force of limbs and the tip force according to dynamics of limbs is given to the muscle force estimation method using the FEM theory. For the exercise using the manipulator for lower limbs, the estimation result of the proposed method is similar to Okuyama's muscle force estimation method which uses joint torque considering dynamics of limbs while the computation time is shorter than the Okuyama's method.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126738931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Christophe Halgand, P. Souéres, Y. Trotter, S. Celebrini, C. Jouffrais
{"title":"A robotics approach for interpreting the gaze-related modulation of the activity of premotor neurons during reaching","authors":"Christophe Halgand, P. Souéres, Y. Trotter, S. Celebrini, C. Jouffrais","doi":"10.1109/BIOROB.2010.5626887","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5626887","url":null,"abstract":"This paper deals with the modeling of the activity of premotor neurons associated with the execution of a visually guided reaching movement in primates. We address this question from a robotics point of view, by considering a simplified kinematic model of the head, eye and arm joints. By using the formalism of visual servoing, we show that the hand controller depends on the direction of the head and the eye, as soon as the hand-target difference vector is expressed in eye-centered coordinates. Based on this result, we propose a new interpretation of previous electrophysiological recordings in monkey, showing the existence of a gaze-related modulation of the activity of premotor neurons during reaching. This approach sheds a new light on this phenomenon which, so far, is not clearly understood.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115108248","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jan Paskarbeit, J. Schmitz, M. Schilling, A. Schneider
{"title":"Layout and construction of a hexapod robot with increased mobility","authors":"Jan Paskarbeit, J. Schmitz, M. Schilling, A. Schneider","doi":"10.1109/BIOROB.2010.5626605","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5626605","url":null,"abstract":"In this paper we concentrate on the design and construction of a novel insectoid walking machine which considers important aspects of arthropods to provide an optimal bodily framework for bioinspired control approaches for walking [4]. In biological systems, control structures and body features have been subject to the same evolutional process. To benefit from bioinspired control approaches it is therefore fundamental to identify the most important body aspects in biological examples and to transfer body features and control approaches as pairs to the technical system. One example for these pairs is the local joint control during the stance phase of walking [9] and elastic features of the joint-driving muscles. A second example is the optimisation of joint-torques and the structural stability of leg segments as a result of the slanted axes in insect legs [6]. Following this train of thought, we introduced novel bioinspired elastic joint drives in the robot. The joint axes orientations, the leg onsets and the overall dimensions of the body and leg segments have been adopted and scaled-up from the biological model. To increase the range of movements, additional 2 DoF joints were introduced in between the individual body segments.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122211668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
G. D. Johnson, Nicholas R. Waytowich, Daniel Cox, D. Krusienski
{"title":"Extending the discrete selection capabilities of the P300 speller to goal-oriented robotic arm control","authors":"G. D. Johnson, Nicholas R. Waytowich, Daniel Cox, D. Krusienski","doi":"10.1109/BIOROB.2010.5628039","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5628039","url":null,"abstract":"A brain-computer interface (BCI), a system that translates a user's brain activity into device commands, can provide a non-muscular means for disabled individuals to interact with their environment. The P300 event-related potential, a transient brain response to a sensory stimulus, has been demonstrated to be a reliable brain signal for controlling a BCI. Traditionally, P300-based BCIs have been used for simple typing tasks using a P300 Speller application, which mimics the functionality of a computer keyboard. Here we extend the discrete selection capabilities of the P300 Speller to achieve high-level control of a 6 degree-of-freedom robotic arm. This study aims to determine if a user's performance, measured in accuracy and communication rate, is affected when a P300 Speller is used to control a robotic arm compared to simple typing. The results indicate that a user's performance is not significantly affected whether typing or controlling a robotic arm.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130223946","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Single-input single-output EMG-based musculoskeletal modeling for hand tremulous motion","authors":"R. Ruwadi, P. Poignet, Han Ming Li, Ang Wei Tech","doi":"10.1109/BIOROB.2010.5625968","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5625968","url":null,"abstract":"Musculoskeletal system modeling is one of the most challenging problems in rehabilitation engineering, especially when body part position or motion control is involved. Musculoskeletal system is known to be highly nonlinear due to complicated actuation mechanism of the muscle fiber to generate observable / measurable motion. Numerous researchers have proposed models with different approaches to meet the requirements for various applications. Complicated models are usually corresponding to complicated model parameters identification methods or procedures. A simple procedure for identification of the model parameters is preferred in most of modeling related to control problems.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"252 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"113997759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Maria Scorcia, D. Formica, N. L. Tagliamonte, D. Campolo, E. Guglielmelli
{"title":"Effects on human motor strategies of physical interaction with a force-controlled wrist rehabilitation robot","authors":"Maria Scorcia, D. Formica, N. L. Tagliamonte, D. Campolo, E. Guglielmelli","doi":"10.1109/BIOROB.2010.5627821","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5627821","url":null,"abstract":"In this work we analyze the effects of a force control scheme, implemented on a robot for wrist rehabilitation (InMotion3 by Interactive Motion Inc. [1]) to reduce the perceived mechanical impedance, on human motor strategies during pointing tasks. Previous studies showed that mechanical impedance of the robot interferes with natural motor strategies [2]. Three healthy subjects performed pointing tasks in three different operative ways: i) with a lightweight hand-held device (capable of measuring wrist rotations without introducing negligible loading effects); ii) with the InMotion3 controlled using the default control with the impedance parameters set to zero; iii) with the same robot, controlled using a direct force control scheme, which reduces the perceived mechanical impedance. In order to study the effects of the force control on the intrinsic kinematic constraints, we assessed wrist rotations with the same protocol we already used to study wrist motor strategies during redundant pointing tasks. The thickness of Donders surfaces (see [3] and [4] for details) indicates how much a soft constraint (such as Donders Law) applies to wrist kinematics during pointing tasks. The effects of force control can be primarily found in the variability of the fitted surfaces as well as in their thickness values. In particular, thickness values, which for the uncontrolled robot are one order of magnitude smaller than the physiological values (suggesting that the constraint has a mechanical origin rather than a neural one), return back into the physiological range in the case of the force-controlled robot.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126417612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Control of pneumatic five-fingered robot hand using antagonistic muscle ratio and antagonistic muscle activity","authors":"Yuki Honda, F. Miyazaki, A. Nishikawa","doi":"10.1109/BIOROB.2010.5627770","DOIUrl":"https://doi.org/10.1109/BIOROB.2010.5627770","url":null,"abstract":"Recently, research into robots that coexist with people in areas such as the service and medical industries is active. Such robots need to be both safe and flexible. To satisfy this demand, a pneumatic actuator is appropriate because it has natural compliance and is lightweight. Our research focuses on a joint angle control method for a five-fingered robot hand using low-pressure driven pneumatic actuators. This robot imitates the structure of the human hand, which has antagonistic muscle pairs for each joint. We proposed a biologically-inspired control method using the following parameters: “antagonistic muscle ratio” and “antagonistic muscle activity”, and implemented the proposed method in a five-fingered robot hand.","PeriodicalId":235728,"journal":{"name":"2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"164 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127399866","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}