2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena最新文献

筛选
英文 中文
Lightning Impulse Behavior Of Conducting Composite Electrodes 导电复合电极的雷电冲击行为
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312076
M. Runde, O. Lillevik, P. Roséen, O. Granhaug, R. Espeseth, P. Skryten
{"title":"Lightning Impulse Behavior Of Conducting Composite Electrodes","authors":"M. Runde, O. Lillevik, P. Roséen, O. Granhaug, R. Espeseth, P. Skryten","doi":"10.1109/CEIDP.2006.312076","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312076","url":null,"abstract":"During lightning impulse type testing of medium voltage switchgears up to two spark-overs are accepted. Consequently, when selecting conducting composites for use in screens and shields of such equipment it is important that their surfaces not degrade after a spark-over, as this normally will reduce the overall dielectric withstand level. Lightning impulse tests where one electrode is coated with polycarbonate based conducting composites have been carried out. With conductive filler of stainless steel fibers heavy surface damage occurs during spark-overs, causing fibers to stick out and thereby lowering the dielectric strength. Carbon fibers filler shows a similar behavior, but to a much lesser extent. For polycarbonate filled with carbon powder some kind of conditioning effect takes place, causing the dielectric strength of the system to increase, and no surface damage is observable even after dozens of spark-overs.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126908479","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Space Charge Evolution in XLPE with Long-term Aging under DC Voltage - the Effect of Temperature and Polarity Reversals 直流电压下长期老化XLPE的空间电荷演化——温度和极性反转的影响
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311988
M. Abou-Dakka, A. Bulinski, S. Bamji
{"title":"Space Charge Evolution in XLPE with Long-term Aging under DC Voltage - the Effect of Temperature and Polarity Reversals","authors":"M. Abou-Dakka, A. Bulinski, S. Bamji","doi":"10.1109/CEIDP.2006.311988","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311988","url":null,"abstract":"DC field long-term breakdown characteristics of commercially available cable-grade cross-linked polyethylene (XLPE) and tree retardant XLPE (TR-XLPE) were investigated. At room temperature, under a unipolar field of 50 kV/mm, more than 90% of XLPE specimens survived 52, 000 h (~6 yrs) of aging, whereas all TR-XLPE specimens broke down within less than 1, 200 h. Reversing the polarity increased the life-time of TR-XLPE by more than 20 times but reduced significantly the life-time of the XLPE specimens. At 75 degC and with polarity reversals both materials survived almost 21, 000 h without any breakdown. These results are discussed in terms of the space charge accumulation and retention properties of the two materials with emphasis on the role of additives in determining insulation properties under DC fields.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"80 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116257903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Corona Ring Design of ±800kV DC Composite Insulator Based on Computer Analysis 基于计算机分析的±800kV直流复合绝缘子电晕环设计
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311968
W. Sima, Kun Wu, Qing Yang, Caixin Sun
{"title":"Corona Ring Design of ±800kV DC Composite Insulator Based on Computer Analysis","authors":"W. Sima, Kun Wu, Qing Yang, Caixin Sun","doi":"10.1109/CEIDP.2006.311968","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311968","url":null,"abstract":"This paper presents a 3D electric-field calculation model of the plusmn800 kV DC transmission line composite insulators based on finite element method. With this 3D model, this paper introduces the effect of the tower, transmission lines and the parameters of the corona rings on the potential and e-field distribution along the composite insulators, and optimizes the corona ring design in order to control the maximum e-field along the insulator surface and corona ring surface.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127882579","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Change in Electroluminescence Activity in Polymers Prior to AC Dielectric Breakdown 交流介质击穿前聚合物电致发光活性的变化
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312083
D. Mary, D. Malec
{"title":"Change in Electroluminescence Activity in Polymers Prior to AC Dielectric Breakdown","authors":"D. Mary, D. Malec","doi":"10.1109/CEIDP.2006.312083","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312083","url":null,"abstract":"The electroluminescence activity of different polymers (LDPE, PI, PET, PP and PEN) has been investigated from low to high AC 50 Hz electric fields. Experiments have been focused on the evolution of the electroluminescence intensity versus applied voltage. Three different electroluminescence regimes have been distinguished for both studied polymers.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128042660","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Towards water-resistant high voltage insulation systems: An ageing study of a technological water-blocking polymer 迈向防水高压绝缘系统:技术阻水聚合物的老化研究
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311982
L. L. Barré, Alun Vaughan, Simon Sutton
{"title":"Towards water-resistant high voltage insulation systems: An ageing study of a technological water-blocking polymer","authors":"L. L. Barré, Alun Vaughan, Simon Sutton","doi":"10.1109/CEIDP.2006.311982","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311982","url":null,"abstract":"This paper examines the solid state ageing characteristics of a technological water-blocking system, based upon the polysaccharide guar, a material used in lightweight power cable designs as a water tree inhibiting system. Through a combination of viscometry and Raman spectroscopy, we show that ageing primarily affects the polymer backbone, which is not associated with guar/water interactions. We conclude that guar binds strongly with water and that this is not affected significantly by ageing. Guar therefore constitutes an attractive means of protecting high voltage insulation systems from exposure to water, so reducing the likelihood of water treeing, even following many years of ageing.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122000217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effects of X-Ray Radiation on Solid Insulating Materials x射线辐射对固体绝缘材料的影响
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.311976
S. Sudalaimuthu, M. Thomas, S. Senthil Kumar, V. Vinod Kumar
{"title":"Effects of X-Ray Radiation on Solid Insulating Materials","authors":"S. Sudalaimuthu, M. Thomas, S. Senthil Kumar, V. Vinod Kumar","doi":"10.1109/CEIDP.2006.311976","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.311976","url":null,"abstract":"In the present work an attempt has been made to study the effects of ionizing radiation such as X-ray irradiation on the electrical properties of solid insulating materials such as FR4 laminates and relate these to concurrent changes in the physical and chemical properties of the above material. FR4 laminates find extensive use as an insulating material in PCB's where HV power supply components are mounted in X-ray generators. In the present work samples of FR4 laminates were irradiated in ambient air with X-rays to different absorbed doses of up to 6.3 times 104 rad. The post irradiation effects on the material shows deterioration in electrical properties such as dielectric strength, dissipation factor, volume resistivity and surface resistivity. Analysis by FTIR indicates that when samples are irradiated in air, it exhibits increase of hydroxyl groups and decrease of all the characteristic infrared bands of the initial chemical functions. SEM photographs show newer defects generated in the irradiated sample. There is also a change in color of the material when exposed to X-rays and this is due to the fact that X-ray initiated free charge gets trapped by the defects/impurities and changes the absorption characteristic of the material. In addition, the decrease in crystallinity and increase in surface roughness was monitored by Differential Scanning Calorimetry and contact type profilometer.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131384094","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Impulsive strength of power cables with different XLPE compounds 不同交联聚乙烯复合材料电力电缆的脉冲强度
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312104
M. Marzinotto, C. Mazzetti, M. Pompili, P. Schiaffino
{"title":"Impulsive strength of power cables with different XLPE compounds","authors":"M. Marzinotto, C. Mazzetti, M. Pompili, P. Schiaffino","doi":"10.1109/CEIDP.2006.312104","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312104","url":null,"abstract":"Standard lightning impulsive dielectric strength tests were performed on cable model samples manufactured with the same technology and the same materials used for high voltage cable application. In particular four different commercial XLPE compounds are considered. Tests were carried out with the aim to investigate the impulsive strength behaviour at room and 90 degC of the compounds when they are subjected to both positive and negative testing wave polarities. The results have been compared in terms of Weibull scale and shape parameters.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134187837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
An Experimental Evaluation on Ozone Generation by Local Discharge Type Gas Jets 局部放电式气体射流产生臭氧的实验评价
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312090
T. Shirotsuka, R. Ohyama
{"title":"An Experimental Evaluation on Ozone Generation by Local Discharge Type Gas Jets","authors":"T. Shirotsuka, R. Ohyama","doi":"10.1109/CEIDP.2006.312090","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312090","url":null,"abstract":"A new type ozone generator with local dielectric barrier discharges operated in very thin gas jets has been experimentally investigated for evaluating an efficient generation process of the ozonic atmosphere. The use of gas jets is to improve an enhancement of the barrier discharges and a cooling effect on the efficiency. The experiments have been conducted to characterize the ozone generation process under following variable parameters: inputted discharge power from a high-voltage source, flow rate of the injected gas jets, and discharge electrode arrangements for optimizing the efficiency. In this paper, a fundamental design of the ozone generator and some quantitative results are presented. The experimentally obtained evaluation indicates an effective performance for the efficiency in a lower range of discharge power.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126585184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Linear Discriminant Analysis for Partial Discharge Classification on High Voltage Equipment 高压设备局部放电分类的线性判别分析
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312010
V. Chatpattananan
{"title":"Linear Discriminant Analysis for Partial Discharge Classification on High Voltage Equipment","authors":"V. Chatpattananan","doi":"10.1109/CEIDP.2006.312010","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312010","url":null,"abstract":"This document is addressing a problem in classifying partial discharge types using linear discriminant analysis. Four PD types generated in the lab are corona at high voltage side in air, corona at low voltage side in air, surface in air, and internal discharge. The independent variables used in this linear discriminant analysis model mainly are from skewness, kurtosis, asymmetry, and cross correlation following the Phi - q - n PD patterns obtained from the fingerprint analysis which is a digital signal processing technique for PD measurement. This document also applied step wise model selection technique to reduce from 10 independent variables to 8 independent variables that not only reduces the complexity of the model estimated but also retains the accuracy of this predictive model to 98.7 percent.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125208778","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of conditions of partial discharges inception and development at non-sinusoidal testing voltages 非正弦测试电压下局部放电发生和发展的条件分析
2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena Pub Date : 2006-10-01 DOI: 10.1109/CEIDP.2006.312015
B. Florkowska, P. Zydroń
{"title":"Analysis of conditions of partial discharges inception and development at non-sinusoidal testing voltages","authors":"B. Florkowska, P. Zydroń","doi":"10.1109/CEIDP.2006.312015","DOIUrl":"https://doi.org/10.1109/CEIDP.2006.312015","url":null,"abstract":"Progress in construction of electrical insulation systems needs new investigations of partial discharges (PD) mechanisms. Working conditions and exploitation stresses, i.e. overvoltages, harmonics and other disturbances have crucial influence on arising of PD in insulation systems. Their influence on partial discharge development is different from normal conditions at nominal sinusoidal voltage. In such a cases interpretation of measurement results (by classical or phase-resolved PD images method) could be more difficult. Paper presents influence of sinusoidal and non-sinusoidal testing voltages (triangular and trapezoidal) on partial discharge distributions, their parameters and changes with increasing of applied voltage. The test object was real insulation system (stator bar thermo-setting insulation system) with many internal PD sources. Presented results of measurements made for sinusoidal, triangular and trapezoidal voltages show the PD mechanism in these conditions. Slew-rate of applied voltage with fixed peak voltage value determines specific conditions for PD generation and has important consequences for phase location of discharges.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131021276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信