2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)最新文献

筛选
英文 中文
Two-phase flow control of on-chip two-phase cooling systems of servers 服务器片上两相冷却系统的两相流控制
J. Marcinichen, J. Thome
{"title":"Two-phase flow control of on-chip two-phase cooling systems of servers","authors":"J. Marcinichen, J. Thome","doi":"10.1109/STHERM.2012.6188822","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188822","url":null,"abstract":"Thermal designers of data centers and server manufacturers are showing a great concern regarding the cooling of new generation data centers, which are more compact and dissipate more power than is currently possible to cool by conventional air conditioning systems. With very large data centers exceeding 100 000 servers, some consume more than 50 MW [1] of electrical energy to operate, energy which is directly converted to heat and then simply wasted as it is dissipated into the atmosphere. A potentially significantly better solution would be to make use of on-chip two-phase cooling [2], which, besides improving the cooling performance at the chip level, also adds the capability to reuse the waste heat in a convenient manner, since higher evaporating and condensing temperatures of the two-phase cooling system (from 60-95°C) are possible with such a new green cooling technology. In the present project, two such two-phase cooling cycles using micro-evaporation technology were experimentally evaluated with specific attention being paid to energy consumption, overall exergetic efficiency and controllability. The main difference between the two cooling cycles is the driver, where both a mini-compressor and a gear pump were considered. The former has the advantage due to its appeal of energy recovery since its exergy potential is higher and the waste heat is exported at a higher temperature for reuse.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123051230","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Performance improvements of air-cooled thermal tool with advanced technologies 采用先进技术改进风冷式热工具的性能
R. Mohammed, Yi Xia, R. Sahan, Y. Pang
{"title":"Performance improvements of air-cooled thermal tool with advanced technologies","authors":"R. Mohammed, Yi Xia, R. Sahan, Y. Pang","doi":"10.1109/STHERM.2012.6188873","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188873","url":null,"abstract":"Air-cooled based thermal margining tool is simple, less costly and reliable cooling solution compared to liquid-cooled thermal tool. Air-cooled thermal tool is used by many Intel® groups for different purposes such as CPU, chipset or ASIC debug and validation. However, conventional air-cooled thermal margining tool do not provide sufficient cooling due to the increasing challenges in thermal management, such as form factor constraint, high power density and noise level limitation. High performance cooling technologies need to be investigated to meet the increasing demand for thermal performance. This paper introduces four advanced cooling strategies, their implementation and ongoing prototyping efforts to achieve performance improvement for air-cooled thermal tool design. In specific, this paper studies the optimization of heat sink design with different fin materials, different embedded heat pipe sizes and numbers, vapor chamber base, liquid chamber base, and combinations of different cooling technologies. The results show that copper fin with liquid chamber base and four φ8mm heat pipes provide the best thermal performance among all the technologies studied.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121056842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Sustainable data centers powered by renewable energy 可再生能源驱动的可持续数据中心
L. Klein, S. Bermudez, Hans-Dieter Wehle, S. Barabasi, H. Hamann
{"title":"Sustainable data centers powered by renewable energy","authors":"L. Klein, S. Bermudez, Hans-Dieter Wehle, S. Barabasi, H. Hamann","doi":"10.1109/STHERM.2012.6188874","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188874","url":null,"abstract":"The energy consumption of data centers (DCs) has dramatically increased in recent years, primarily due to the massive computing demands driven by communications, banking, online retail, and entertainment services. In today's data centers, the cooling and infrastructure operations require almost the same energy as the IT operations. The large energy consumption in data centers prompted government agencies, industries, professional organizations, and academic institutions to investigate sustainable growth paths. We discuss such scenarios based on current trends and projections and propose the required innovations to achieve a 10 fold increase in “performance per Watt” of IT operations. We discuss three possible technology components that would improve the operational performance of data centers: (1) integration of renewable energy sources (2) increasing energy efficiency through IT consolidation and workload optimization, and (3) multifunctional sensor networks for better cooling and infrastructure management. We discuss the key requirements and how these technologies can be combined to achieve a sustainable path.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125391352","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Experimental investigation of water cooled server microprocessors and memory devices in an energy efficient chiller-less data center 高效节能无冷却器数据中心中水冷服务器微处理器和存储设备的实验研究
P. Parida, M. David, M. Iyengar, M. Schultz, M. Gaynes, V. Kamath, B. Kochuparambil, T. Chainer
{"title":"Experimental investigation of water cooled server microprocessors and memory devices in an energy efficient chiller-less data center","authors":"P. Parida, M. David, M. Iyengar, M. Schultz, M. Gaynes, V. Kamath, B. Kochuparambil, T. Chainer","doi":"10.1109/STHERM.2012.6188852","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188852","url":null,"abstract":"Understanding and improving the thermal management and energy efficiency of data center cooling systems is of growing importance from a cost and sustainability perspective. Toward this goal, warm liquid cooled servers were developed to enable highly energy efficient chiller-less data centers that utilize only “free” ambient environment cooling. This approach greatly reduces cooling energy use, and could reduce data center refrigerant and make up water usage. In one exemplary experiment, a rack having such liquid cooled servers was tested on a hot summer day (~32°C) with CPU exercisers and memory exercisers running on every server to provide steady heat dissipation from the processors and from the DIMMs, respectively. Compared to a typical air cooled rack, significantly lower DIMM temperatures and CPU thermal values were observed.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130492492","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 23
Performance optimization of multi-core processors using core hopping - thermal and structural 基于核跳变的多核处理器性能优化——热和结构
Sunil Lingampalli, F. Mirza, T. Raman, D. Agonafer
{"title":"Performance optimization of multi-core processors using core hopping - thermal and structural","authors":"Sunil Lingampalli, F. Mirza, T. Raman, D. Agonafer","doi":"10.1109/STHERM.2012.6188835","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188835","url":null,"abstract":"As the work load on the single core processor increases, its power density and the die temperature increases as well. The increase in the die temperature results in decreased performance, reliability and increased leakage currents and cooling cost. Also, the non-uniform power distribution across the die results in hot spots. In order to decrease the work load and the cooling cost on the single core processor, multi-core processors have been implemented. Multicore Processors also known as Chip Multi Processors (CMP's). CMPs are processors which contain two or more independent cores on a chip. In CMPs, if one core reaches its critical temperature, the workload is transferred to the other. This phenomenon is termed as core hopping. Core hopping facilitates uniform distribution of the work load among the many cores and leads to improvements in the performance and reliability. The demand for greater performance in applications involving high levels of computing has resulted in many cores being put on a single chip. Every succeeding processor is predicted to hold double the number of cores than the previous one. In this study, core hopping for CMPs is analyzed and the thermal analysis of the chip with core hopping is performed using ANSYS Fluent. The hop sequence is analyzed as a function of chip temperature distribution and a numerical methodology to analyze the coupled thermal and structural integrity of the CMPs is demonstrated.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133074760","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Development of a flexible chip infrared (IR) thermal imaging system for product qualification 柔性芯片红外热成像系统的研制
C. Lian, M. Knox, K. Sikka, Xiaojin Wei, A. Weger
{"title":"Development of a flexible chip infrared (IR) thermal imaging system for product qualification","authors":"C. Lian, M. Knox, K. Sikka, Xiaojin Wei, A. Weger","doi":"10.1109/STHERM.2012.6188870","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188870","url":null,"abstract":"A flexible and efficient chip Infrared (IR) thermal imaging system was implemented on the product manufacturing test platform by collaboration with the burn-in/wafer test, systems, process, and failure analysis teams. A liquid cooling cell was successfully designed and tested. The imaging system was applied to investigate some wafer probe power/thermal issues for server high end products. Furthermore, we applied the method of Spatially-resolved Imaging of Microprocessor Power (SIMP) [1] to translate the thermal map into a power map. Finally, we propose a new concept of product thermal qualification as a supplement and potential alternative to the traditional thermal test vehicle (TTV) qualification.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115502858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Energy reduction in server cooling via real time thermal control 通过实时热控制降低服务器冷却能耗
Xuefei Han, Y. Joshi
{"title":"Energy reduction in server cooling via real time thermal control","authors":"Xuefei Han, Y. Joshi","doi":"10.1109/STHERM.2012.6188829","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188829","url":null,"abstract":"Currently, server fans often over-cool the CPUs, contributing to increased use of energy. A thermal model-based real-time fan controller was studied in this paper to reduce the energy consumption in server CPU fans. A reduced order model of the server CPU and its heatsink was developed using proper orthogonal decomposition (POD), which provided 180 times faster simulation times, with reasonable accuracy. This was used in conjunction with a fan control strategy to achieve 27% savings in energy consumed for cooling.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129213525","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
High performance thermal interface materials with enhanced reliability 高性能热界面材料,增强可靠性
Sihai Chen, N. Lee
{"title":"High performance thermal interface materials with enhanced reliability","authors":"Sihai Chen, N. Lee","doi":"10.1109/STHERM.2012.6188872","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188872","url":null,"abstract":"Reliability has been a critical issue for thermal interface materials, especially when the materials are used for high power applications. In this paper, a series of reliability tests including baking, humidity chamber, temperature cycling, power cycling, and thermal shock have been conducted. Through comparison with conventional thermal pastes or phase change materials, a novel thermal paste with enhanced reliability is introduced. A mechanistic study has been performed to understand the reason for enhanced reliability. This paste possesses the following features and benefits: (1) Room temperature storage (2) No pump out or dry out (3) Compliable to interfaces (4) Minimal bond strength (5) No need to cure (6) No need to pre-reflow (7) Good tack for component holding (8) Easily printed or dispensed (9) Direct replacement for grease (10) Re-workable This makes it a promising candidate for an advanced thermal dissipation solution in a variety of industrial applications.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"277 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131571564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Enhancement of photovoltaic solar module performance for power generation in the Middle East 提高中东地区光伏太阳能组件的发电性能
V. Eveloy, P. Rodgers, S. Bojanampati
{"title":"Enhancement of photovoltaic solar module performance for power generation in the Middle East","authors":"V. Eveloy, P. Rodgers, S. Bojanampati","doi":"10.1109/STHERM.2012.6188831","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188831","url":null,"abstract":"Despite the abundance of solar energy in the Middle East, the efficiency and reliability of photovoltaic (PV) modules is severely affected by elevated cell operating temperature, which reduces the effectiveness of sun tracking techniques. In this study the potential of water-cooling to improve the electrical performance of stationary and sun-tracked PV modules is experimentally investigated for application at off-shore oil and gas facilities in the Persian Gulf. In parallel with measurements of PV module electrical characteristics and operating temperature, global solar irradiation, ambient air and cooling water temperatures, wind velocity and relative humidity are also recorded. In autumn conditions in the United Arab Emirates (24.43°N, 54.45°E), water-cooling is found to reduce PV module operating temperature by up to 30°C relative to passive cooling conditions, depending on operating conditions. Using water-cooling, power output is enhanced for a significant portion of the day for fixed geographical South facing modules (e.g., 22% at solar noon, and 13% at 2 p.m.) relative to passive cooling, and even more significantly for sun-tracked modules (e.g., 20% at 2 p.m.). Sun tracking enhances power output by 16% and 24% for passively- and water-cooled modules, respectively, at for example 2 p.m. The incorporation of water-cooling and sun tracking is the most effective, with enhancements in output power of on order 40% at for example 2 p.m. relative to passively-cooled, fixed South facing operation. In winter conditions (e.g., December), modest reductions in operating temperature and improvements in electrical performance are obtained using water-cooling and/or sun tracking, which may not justify the associated capital and operating costs.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133249738","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 28
Datacenter power savings through high ambient datacenter operation: CFD modeling study 通过高环境数据中心运行的数据中心节能:CFD建模研究
N. Ahuja
{"title":"Datacenter power savings through high ambient datacenter operation: CFD modeling study","authors":"N. Ahuja","doi":"10.1109/STHERM.2012.6188833","DOIUrl":"https://doi.org/10.1109/STHERM.2012.6188833","url":null,"abstract":"In a typical datacenter, almost 40% of the total power consumption is spent on datacenter cooling. In addition, the capital expenditure costs for the cooling infrastructure are also significant. Large Internet Portal Datacenters are looking at every possible way to reduce the cooling cost. One of the emerging trends in the industry is to move to higher ambient datacenter operation. Some datacenter operators are even wanting to operate the datacenters at ambient as high as 40C. It is shown that both server power increase and facility level cooling power savings must be considered to determine net power savings at the datacenter level. CFD modeling is used to demonstrate that following best practices in airflow management: using blanking panels, floor layout, eliminating cable obstructions, hot/cold aisle containment and bypass and re-circulation reduction are first important steps to get ready for high ambient datacenter operation. It is shown that without these practices, there is large variation in inlet air temperature from one server to other creating hotspots forcing thermostats on CRAC units to be set low. It is shown that CFD modeling can be used to quantify how cooling path management improves with hot/cold aisle containment. The study shows that significant datacenter level power savings can be achieved by operating the datacenter up to 35C with the use of Economizers.","PeriodicalId":216187,"journal":{"name":"2012 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2012-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133921252","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书