Mica paper insulations for conductors and cables 导体和电缆用云母纸绝缘
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461952
W. Andres
{"title":"Mica paper insulations for conductors and cables","authors":"W. Andres","doi":"10.1109/EIC.1977.7461952","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461952","url":null,"abstract":"The use of mica paper as insulation on magnet wires for high-voltage machines and traction motors is possible. The insulation is mechanically sufficiently strong enough for producing any kind of formed coils. The main advantages of mica paper covered magnet wires are the good dielectric properties and the corona resistance of the insulation. Certain types of mica paper tapes can also be used as cable insulation which belongs to the thermal class H. The cable insulation is resistant against moisture, mineral oils, corona, radiation and has excellent dielectric properties. In case of fire the mica paper covered cable is not producing any poisonous gases. This type of cable is suitable for leads in rotating machines of all kind, for power and auxiliary circuits in electrical vehicles, vessels, nuclear power stations, oil refineries etc.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128858967","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A novel method for evaluating high temperature mechanical and thermal properties of laminated thermosetting insulating plastics 一种评价层合热固性绝缘塑料高温力学和热性能的新方法
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461954
C. Photiadis, S. Gause
{"title":"A novel method for evaluating high temperature mechanical and thermal properties of laminated thermosetting insulating plastics","authors":"C. Photiadis, S. Gause","doi":"10.1109/EIC.1977.7461954","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461954","url":null,"abstract":"For some time the question of how to choose effectively the proper insulating material for use in electric motors and generators as a stress member has been bandied about by many different people. This problem becomes increasingly more difficult when high temperatures and stresses are encountered particularly when said item is used as a restraining wedge in what is popularly called an open slot armature.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127763519","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Composite epoxy glass-microsphere dielectric for hermetic SMA type RF connectors 复合环氧玻璃微球电介质,用于密封SMA型射频连接器
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461912
Patricia A. Fritzen, P. Planting
{"title":"Composite epoxy glass-microsphere dielectric for hermetic SMA type RF connectors","authors":"Patricia A. Fritzen, P. Planting","doi":"10.1109/EIC.1977.7461912","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461912","url":null,"abstract":"The development of a composite epoxy glass-microsphere dielectric for hermetic SMA type R.F. connectors is described. The emphasis is on the selection of a moisture resistant combination of epoxy resin, curing agent, glass microspheres, and silane coupling agent that meets the electrical and physical requirements for an SMA connector up to 26.5 GHz. The material selected for evaluation in prototype connectors has a dielectric constant of 2.06, insertion loss of 1.06 dB/inch @ 26.5 GHz, and a coefficient of thermal expansion of 25 ± 2 × 10−6cm/cm/°C. Prototype connectors were fabricated by injecting the uncured dielectric into the connector barrel, then curing the material to form a hermetic seal. The connectors maintained a leak rate ≤1 ×10−7 cc He/sec. before and after exposure to MIL-STD 883, Class B environmental tests. The physical strength of the epoxy dielectric compares favorably with glass-to-metal seals.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121432715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mechanical fatigue strength of micaeous composite insulation 云母复合绝缘材料的机械疲劳强度
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461941
K. Shibayama, T. Kitagawa
{"title":"Mechanical fatigue strength of micaeous composite insulation","authors":"K. Shibayama, T. Kitagawa","doi":"10.1109/EIC.1977.7461941","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461941","url":null,"abstract":"Mica has been used favorably as the main barrier material for machine coil insulation. Recent extension of the mica paper (reconstituted mica) is due to advantages relative to economy, homogenous quality and development of synthetic resins for use in a reliable composite insulation. Several kinds of mica papers are presently available. These mica papers are produced by different processes and from different raw materials. It is natural that they have different flake size and surface properties which may affect the final properties of the composite insulation.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130337146","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
P-vinyl phenol polymer — A highly heat resistant new material for insulation 对乙烯基苯酚聚合物——一种高耐热的新型绝缘材料
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461958
Asao Takahashi, M. Shimizu, Tetsuichiro Horio
{"title":"P-vinyl phenol polymer — A highly heat resistant new material for insulation","authors":"Asao Takahashi, M. Shimizu, Tetsuichiro Horio","doi":"10.1109/EIC.1977.7461958","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461958","url":null,"abstract":"Maruzen Resin M (poly p-vinyl phenol) and Maruzen Resin MB (brominated poly p-vinyl phenol) are new materials developed recently. They are easily cured with epoxy resins without generating volatiles, and yield crosslinked products possessing superior performances for insulation. Epoxy-cured Resin M is suitable for FRP, especially for high grade printed circuit board because of its excellent thermal stabilities (solder resistance, flexural strength, peel strength and electric prperties under high temperature), drilling performances and chemical resistances. The thermal properties are comparable to those of polyimide, and processing conditions are similar to conventional heat-stable epoxy resins. Flame retardant type composite can be obtained by using Resin MB, with little affection to the improved properties above-mentioned. Epoxy-cured Resins M and MB also give electric insulators and structural materials keeping superior thermal and electric performances by molding or casting. Furthermore, the resins are expected to be useful for widespread applications such as adhesives, coatings etc., where high heat-resistance is required.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130919663","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An improved materials system for maintaining high resistivity of electrical insulation in humid environments 一种在潮湿环境中保持电绝缘高电阻率的改进材料体系
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461927
C. Harper
{"title":"An improved materials system for maintaining high resistivity of electrical insulation in humid environments","authors":"C. Harper","doi":"10.1109/EIC.1977.7461927","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461927","url":null,"abstract":"One of the environments which has long been considered hostile to electrical insulation is that of elevated humidity. In this environment, severe degradation of insulation resistance is among the significant effects on electrical insulating materials. This paper discusses the background and nature of the problem of decreasing insulation resistance of electrical insulation in humid environments, and presents an approach for maintaining high insulation resistance during exposure to such humid environments.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132281469","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Energy utilization in curing insulating varnishes 绝缘清漆固化中的能源利用
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461942
C. H. Beckett
{"title":"Energy utilization in curing insulating varnishes","authors":"C. H. Beckett","doi":"10.1109/EIC.1977.7461942","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461942","url":null,"abstract":"Our emphasis is on the energy effectiveness of curing ovens used in the motor repair industry. A brief review of the entire application process will bring energy conservation opportunities into focus.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128291080","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Heat-shrinkable tubing: What makes it tick? 热缩管:是什么让它滴答作响?
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461957
R. Timmerman
{"title":"Heat-shrinkable tubing: What makes it tick?","authors":"R. Timmerman","doi":"10.1109/EIC.1977.7461957","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461957","url":null,"abstract":"Twenty-three flexible polyolefin heat shrinkable tubing insulation formulations were subjected to three dose levels of high energy radiation and tested for degree of crosslinking, flammability, tensile strength and elongation, and thermal stability. The effects of component concentration and types on these performance characteristics were determined. Antioxidant concentration and type largely influenced degree of crosslinking as did the sensitizer concentration, whereas stabilizer type and concentration had little effect. Tensile strength and elongation were not largely affected by formulation or radiation dose. High sensitizer concentration tended to improve flame resistance as did higher stabilizer concentrations. Stabilizer type affected flammability. Generally, increased radiation dose tended to improve flame resistance. Thermal stability was improved by changing stabilizer type and lessened by increasing sensitizer concentration or decreasing the antioxidant level.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125194247","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experience with post cured insulation systems for large form wound machines 对大型缠绕机的后固化绝缘系统有经验
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461951
R. Schuler
{"title":"Experience with post cured insulation systems for large form wound machines","authors":"R. Schuler","doi":"10.1109/EIC.1977.7461951","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461951","url":null,"abstract":"Some 12 years ago the introduction of the Micadur ®-Compact post-cured insulation sysstem led to a complete revision of the insulating process for medium to large high-voltage machines, whose stator windings are built up mainly of form-wound coils. Simultaneously the coil-end supports were completely redesigned, resulting in definite progress being made in respect of the reliability of these machines. This is verified by the operating experience gained from thousands of machines which have already given years of satisfactory service. This article describes the testing methods adapted to suit the modified manufacturing process, refers in detail to the experience gained in operation and indicates possible maintenance tests. The satisfactory experience gained in post-cured impregnation techniques have led to machines being built with ratings up to and exceeding 50 MW.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114775760","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Up-dating NEMA magnet wire standards 更新的NEMA磁铁线标准
1977 EIC 13th Electrical/Electronics Insulation Conference Pub Date : 1977-09-01 DOI: 10.1109/EIC.1977.7461986
R. O. Roberds
{"title":"Up-dating NEMA magnet wire standards","authors":"R. O. Roberds","doi":"10.1109/EIC.1977.7461986","DOIUrl":"https://doi.org/10.1109/EIC.1977.7461986","url":null,"abstract":"Ten years have passed since our introduction of MW-1000 in Chicago in 1967. Since then, the standard has been up-dated many times. A total of nine major revisions have been made and issued through the direct mailing revision service. The new 1977 publication, being introduced at: this conference, represents the third edition of MW-1000. These revisions and editions should serve to illustrate the desire and effort of both magnet wire manufacturer and user within NEMA to keep the standard current and up graded. We recognize in order to remain consistant with our advancing industry technology, an up-to-date standard is essential. Our report today will summarize the progress of the technical committees work and highlight the improvements made to MW-1000 since the 1975 Electrical/Electronic Insulation Conference.","PeriodicalId":214025,"journal":{"name":"1977 EIC 13th Electrical/Electronics Insulation Conference","volume":"285 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122970566","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信