24th ISDEIV 2010最新文献

筛选
英文 中文
Computational model of the cathode attachment zone of constricted high current vacuum arcs 缩窄型大电流真空电弧阴极附着区计算模型
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625857
D. Shmelev, T. Delachaux
{"title":"Computational model of the cathode attachment zone of constricted high current vacuum arcs","authors":"D. Shmelev, T. Delachaux","doi":"10.1109/DEIV.2010.5625857","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625857","url":null,"abstract":"This paper is devoted to the modeling of the cathode attachment zone of constricted high current vacuum arcs. Previously, the authors made a simple model of the cathode attachment zone, which was used for modeling of constricted high current vacuum arcs driven by a transverse magnetic field. Here a new sophisticated computational model of the attachment zone is described. With help of Particle-In-Cell and Direct Simulation Monte Carlo (PIC/DSMC) methods, a 1D model of the attachment zone was developed. The model allows us to calculate in detail the state of the charged particles and atoms in the Knudsen layer, ionization layer, and plasma sheath.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126819406","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Study on dynamic arc model for high voltage hybrid circuit breaker using vacuum interrupter and SF6 interrupter in series 真空断流器与SF6断流器串联高压混合断路器动态电弧模型研究
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625840
M. Liao, Xian Cheng, X. Duan, J. Zou
{"title":"Study on dynamic arc model for high voltage hybrid circuit breaker using vacuum interrupter and SF6 interrupter in series","authors":"M. Liao, Xian Cheng, X. Duan, J. Zou","doi":"10.1109/DEIV.2010.5625840","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625840","url":null,"abstract":"Hybrid circuit breaker, consisting of a vacuum interrupter and an SF6 interrupter in series, which take the place of single SF6 circuit breaker, is a research area to low-carbon technology for high-voltage switch. In this paper, the model simulation system of hybrid circuit breaker was established by Alternative Transients Program. The system simulation model establishment mainly includes building the electromagnetic transient simulation platform, setting system circuit parameter, improving SF6 arc model and vacuum arc model, whose parameters were obtained by program calculating. The aim of this paper was to investigate the interactions of vacuum arc and SF6 arc during the breaking process, the voltage distribution of the two breakers, the gain characteristics of the coordination action between two breakers by simulation. The results of simulation showed that vacuum interrupter cooperates with SF6 interrupter well in the current zero period, and a higher breaking capacity can be obtained. The results of simulation were in accordance with the theoretical prediction and prove the validity of theoretical model very well.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123637089","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
From “whiskers” to “dust” - the critical role of dedicated diagnostic techniques in promoting paradigm shift 从“胡须”到“尘埃”——专用诊断技术在促进范式转变中的关键作用
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625888
R. Latham
{"title":"From “whiskers” to “dust” - the critical role of dedicated diagnostic techniques in promoting paradigm shift","authors":"R. Latham","doi":"10.1109/DEIV.2010.5625888","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625888","url":null,"abstract":"The development of theoretical models to explain complex physical processes is an essential part of the scientific method. However, such models must always be the subject of on-going scrutiny and experimental evaluation, and it is in this context that purpose-designed diagnostic techniques play a critical role. This paper presents an historical account of how this process has been crucial in the evolution of our understanding of the underlying physical mechanisms that control the behaviour of the high voltage vacuum gap.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"138 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124344005","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Experiments on dynamic behaviors of small DC current vacuum arc 小直流电流真空电弧的动态特性实验
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625827
T. Imae, Y. Kuroki, E. Kaneko
{"title":"Experiments on dynamic behaviors of small DC current vacuum arc","authors":"T. Imae, Y. Kuroki, E. Kaneko","doi":"10.1109/DEIV.2010.5625827","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625827","url":null,"abstract":"Generally, an arc voltage of a vacuum discharge is relatively low, but it grows very rapidly just after the contact separation. Such a rapid increase of the voltage might cause some kinds of transient phenomena in a closed loop circuit with capacitances and inductances. An oscillating current caused by these transient phenomena can create a current zero at the vacuum arc. If the amplitude of the oscillations is larger than the current there, the arc will be quenched. The authors investigated these phenomena, and presented at the previous ISDEIV meeting. Probability of the current interruption by these transient phenomena is limited, and the arc interruption phenomena were observed, where levels were 20 to 40A. After several tens or hundreds milliseconds, however, the current are suddenly interrupted by spontaneous current oscillation. These oscillations are considered to be related to arc instability. We try to clarify these current interruptions caused by arc instability at larger current levels.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126562521","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Voltage distribution characteristics of multiple-break vacuum circuit breakers 多断路真空断路器的电压分布特性
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625779
Gao-bo Wu, J. Ruan, Daochun Huang, Shengwen Shu
{"title":"Voltage distribution characteristics of multiple-break vacuum circuit breakers","authors":"Gao-bo Wu, J. Ruan, Daochun Huang, Shengwen Shu","doi":"10.1109/DEIV.2010.5625779","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625779","url":null,"abstract":"The static voltage distributions and capacitance matrixes of two triple-break vacuum circuit breakers with different structure arrangements were calculated with the finite element method(FEM). Then the voltage distributions of two arrangements under ac voltages were measured. Experiment results verify the accuracy of the numerical calculations. The results show that the vertical arrangement has a better voltage distribution than the U-shaped arrangement. And the capacitance matrixes are useful to choose suitable grading capacitors. The voltage distribution characteristics after high current interruption was preliminary analyzed. The ohmic impedance of the gap during post-arc current period was calculated using the “Continuous Transition Model” to evaluate its influences on the voltage distribution. The results indicate that the voltage distribution may be determined by the ohmic impedances in the first few microseconds after current zero, especially after arcing conditions followed by large post-arc currents.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"503 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134033187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Voltage holding prediction in multi-electrode multi-voltage systems insulated in vacuum 真空绝缘多电极多电压系统的保压预测
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625752
N. Pilan, P. Veltri, A. de Lorenzi
{"title":"Voltage holding prediction in multi-electrode multi-voltage systems insulated in vacuum","authors":"N. Pilan, P. Veltri, A. de Lorenzi","doi":"10.1109/DEIV.2010.5625752","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625752","url":null,"abstract":"The voltage holding in the 1 MV ITER Neutral Beam Accelerator is recognized to be one of the most critical issues for long lasting beam operation, due to the complex electrostatic structure formed by differently shaped electrodes polarized at different potentials. At present, no model is available to predict the breakdown probability of electrostatic system with a comparable complexity degree. This paper is aimed at proposing an innovative modelling for the voltage breakdown prediction of such complex systems, based on the implementation of the micro particle (clump) induced breakdown Cranberg-Slivkov theory into a statistical approach.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131537564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Switching of capacitive current with vacuum interrupters 用真空灭流器开关容性电流
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625812
G. Sandolache, U. Ernst, X. Godechot, S. Kantas, M. Hairour, L. Dalmazio
{"title":"Switching of capacitive current with vacuum interrupters","authors":"G. Sandolache, U. Ernst, X. Godechot, S. Kantas, M. Hairour, L. Dalmazio","doi":"10.1109/DEIV.2010.5625812","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625812","url":null,"abstract":"Standard vacuum circuit breakers are required to fulfil various needs, e.g. the interruption capability, breaking/making operations. More and more commercial vacuum circuit breakers have to switch capacitive currents in different networks. Further to line and cable charging circuits, single capacitor bank and back-to-back capacitor banks have to be switched with lowest frequency possible. Late breakdowns are potentially dangerous to the installation as they could lead to the build-up of high switching overvoltages that can be harmful to the equipments. IEC and IEEE standards define switching circuits with the main parameters of peak inrush current, inrush frequency and capacitive breaking currents. Real applications often deviate from these parameters. The paper presents the results obtained with a special designed vacuum interrupter designated for capacitive switching investigations. The test was performed at high power station. Various single-bank and back-to-back capacitor bank switching tests have been done with several inrush parameters and capacitor bank current values. The goal of the investigations was to make a statistical correlation between the late breakdowns and potential sources of failure.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127586657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Lighting impulse voltage breakdown characteristics of vacuum interrupters with 10 to 50mm contact gaps 触点间隙为10 ~ 50mm的真空灭弧器的雷击电压击穿特性
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625826
Yingyao Zhang, Zhiyuan Liu, Yingsan Geng, Lanjun Yang, Jimei Wang
{"title":"Lighting impulse voltage breakdown characteristics of vacuum interrupters with 10 to 50mm contact gaps","authors":"Yingyao Zhang, Zhiyuan Liu, Yingsan Geng, Lanjun Yang, Jimei Wang","doi":"10.1109/DEIV.2010.5625826","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625826","url":null,"abstract":"The objective of this paper is to understand the standard lighting impulse voltage breakdown characteristics of vacuum interrupters with contact gaps 10 to 50mm and how contact parameters influence the breakdown characteristics. The investigated contact parameters include contact diameter 75mm and 60mm, contact surface roughness 1.6µm and 3.2µm, and contact radius of curvature 6mm and 2mm. Therefore we designed four high-voltage vacuum interrupters in the experiments. The vacuum interrupters were put into a porcelain envelope with SF6 gas as an external insulation of the vacuum interrupters. The contact gaps can be adjusted manually. Negative polarity basic impulse level (BIL) voltage (1.2×50µs) was applied by an up-and-down method. Experimental results revealed the breakdown probability distribution followed a Weibull distribution when the breakdown voltage saturated in the investigated contact gaps 10 to 50mm. And 50% breakdown voltage U50 depends on the contact gap d (10∼50mm), can be expressed by an equation U50=kdα, where α is a power exponent; k denotes a coefficient which is determined by experiments. Within the contact gaps 10 to 50mm, U50 of vacuum interrupter with contact radius of curvature 2mm was significantly higher than that of vacuum interrupter with contact radius of curvature 6mm. And U50 of contact roughness 1.6µm was close to that of contact roughness 3.2µm. U50 of the contact diameter 60mm was close to that of contact diameter 75mm.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131071168","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
High current vacuum arc phenomena of nanocrystalline CuCr25 contact material 纳米晶CuCr25触点材料的大电流真空电弧现象
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625828
Li Yu, Jianhua Wang, Yingsan Geng, Guowei Kong, Zhiyuan Liu
{"title":"High current vacuum arc phenomena of nanocrystalline CuCr25 contact material","authors":"Li Yu, Jianhua Wang, Yingsan Geng, Guowei Kong, Zhiyuan Liu","doi":"10.1109/DEIV.2010.5625828","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625828","url":null,"abstract":"Research on the vacuum arc phenomena of the nanocrystalline CuCr25 contact material is interested for its potential application on high current interruption. In order to investigate the vacuum arc phenomena of the nanocrystalline CuCr25 contact material, a traditional CuCr25 material was also prepared for comparison. 12mm and 25mm diameter contacts were assembled in vacuum interrupters, which have a glass envelope and no shield. A high-speed CCD camera was used to observe the anode phenomena and the cathode phenomena through the glass envelope. The test vacuum interrupters were operated by a permanent magnet mechanism. The average opening velocity can be adjusted to two velocities: 1.3m/s to 1.8 m/s. The arc current frequency was 50Hz and arc duration was 9ms∼10ms. The experimental results showed that at same current and average opening velocity, the arc energy and the mean value of arc voltage of nanocrystalline CuCr25 was lower than the traditional CuCr25 contact material. The distribution of cathode spots on the nanocrystalline CuCr25 contact was more uniformly than of the traditional CuCr25 contact. And the carrying current per cathode spot of the nanocrystalline contact material was about ⅓ of that of the traditional contact material. However, the anode phenomena of the nanocrystalline CuCr25 contact were more active than the traditional CuCr25 contact material when passing the same high currents. At a threshold current at the first high-current anode mode appeared, it was found that the threshold current of nanocrystalline CuCr25 contact material was lower than that of traditional CuCr25 contact material, which means the nanocrystalline CuCr25 contact material was more prone to appear the high-current anode mode than the traditional CuCr25 contact material.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132891808","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
On plasma flow parameters of nanosecond vacuum spark discharge 纳秒真空火花放电等离子体流动参数研究
24th ISDEIV 2010 Pub Date : 2010-11-09 DOI: 10.1109/DEIV.2010.5625852
I. Muzyukin
{"title":"On plasma flow parameters of nanosecond vacuum spark discharge","authors":"I. Muzyukin","doi":"10.1109/DEIV.2010.5625852","DOIUrl":"https://doi.org/10.1109/DEIV.2010.5625852","url":null,"abstract":"The plasma flow of a nanosecond vacuum spark was investigated with Faraday cup and MCP (micro channel plate) amplifier. It is shown that the plasma flow consists of high-velocity and low velocity parts. High velocity part of plasma flow has small intensity and contains ions with velocities up to 108 cm/sec. Low velocity part has high intensity and contains ions with velocities up to 3 106cm/sec. High-energy electrons, propagating with the plasma flow, were found. Occurrence of these electrons can be explained by plasma instabilities. The measurement of electron energies was done with retarding potential method. The electron energy makes 100eV for low velocity plasma flow, and more than 1 keV for high velocity plasma flow.","PeriodicalId":209149,"journal":{"name":"24th ISDEIV 2010","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115667670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书