Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society最新文献

筛选
英文 中文
Pictorial representation of local events in the heart on the basis of noninvasive spherical-quasiepicardium potential mapping 基于无创球-准心外膜电位映射的心脏局部事件的图像表示
L. Titomir, V. Trunov, I. P. Poljakova
{"title":"Pictorial representation of local events in the heart on the basis of noninvasive spherical-quasiepicardium potential mapping","authors":"L. Titomir, V. Trunov, I. P. Poljakova","doi":"10.1109/IEMBS.1995.575084","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575084","url":null,"abstract":"An improvement of the electrocardiographic body surface potential mapping technique is proposed to provide more explicit recognition of excitation processes in the heart by means of calculation of the potential distribution on the spherical quasiepicardium and separation of its extremum regions. The method is illustrated with cases of ventricular extrasystole and preexcitation syndrome.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"280 ","pages":"229-230 vol.1"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91551709","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An artificial tactile sensor for fine-form discrimination 用于精细形状辨别的人工触觉传感器
F. Germagnoli, S. Lazzari, R. Lombardi, G. Magenes
{"title":"An artificial tactile sensor for fine-form discrimination","authors":"F. Germagnoli, S. Lazzari, R. Lombardi, G. Magenes","doi":"10.1109/IEMBS.1995.579837","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579837","url":null,"abstract":"A new artificial tactile sensor has been developed to provide reliable data about the exploration of small geometrical details of an object (fine-form discrimination). The main characteristics of this sensor are: high spatial resolution, small packaging and flexibility of the support which implies the chance of wearing it as a finger of a glove. This sensor will be applied in both robotic and rehabilitation fields.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"65 1","pages":"1577-1578 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90172609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Subspace identification method for ankle mechanics 踝关节力学的子空间辨识方法
S. Kukreja, B. Haverkamp, D. Westwick, R. Kearney, H. Galiana, M. Verhaegen
{"title":"Subspace identification method for ankle mechanics","authors":"S. Kukreja, B. Haverkamp, D. Westwick, R. Kearney, H. Galiana, M. Verhaegen","doi":"10.1109/IEMBS.1995.579753","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579753","url":null,"abstract":"Presents results a new algorithm for modeling biological systems using a state space approach. One of the MIMO Output-Error State Space identification (MOESP) family of algorithms (see M. Verhaegen and P. Dewilde, Int. J. Control, vol. 55, no. 5, p. 1187-1210, 1992) has been adapted to model the linear part of human ankle mechanics. A mixed causal/anti-causal state space model was calculated to examine the relationship between torque and position of the ankle. Simulated and real data are used to show that the method yields parametric models for ankle mechanics that describe behavior as well as nonparametric models. However, the parametric models obtained using the MOESP identification method have many fewer parameters.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"1 1","pages":"1413-1414 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88922549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Minimal models in meal-like protocols: simulation studies to assess precision and physiological plausibility of parameter estimates 类餐方案中的最小模型:评估参数估计的精度和生理合理性的模拟研究
F. Betrini, A. Caumo, C. Cobelli
{"title":"Minimal models in meal-like protocols: simulation studies to assess precision and physiological plausibility of parameter estimates","authors":"F. Betrini, A. Caumo, C. Cobelli","doi":"10.1109/IEMBS.1995.579727","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579727","url":null,"abstract":"In the present study the authors evaluated the impact of different experimental protocols on glucose minimal models identification. They used a realistic comprehensive nonlinear model of the glucose-insulin system to generate unlabeled and labeled glucose data during an IVGTT and a meal-like study. Subsequently, Monte Carlo simulations were used to compare the values and precision of the estimates of the minimal models indices obtained from the two experimental protocols. The authors' results demonstrate that both the values and the precision of the minimal model parameters are influenced by the experimental protocol. In particular, they found that the minimal model parameters estimated from the meal-like study are less precise but probably more physiologically plausible than those obtained from the IVGTT. The lower precision achieved with the meal-like study protocol is probably due to both the relatively unfrequent sampling schedule and the non-optimality of the glucose and insulin profiles for minimal model analysis.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"17 3","pages":"1361-1362 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91437536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Does pulmonary carcinoma affect the resonant properties of the thorax? 肺癌会影响胸腔的共振特性吗?
A.G. Miller, T. Choy, H. Chan, Y.T. Zhang
{"title":"Does pulmonary carcinoma affect the resonant properties of the thorax?","authors":"A.G. Miller, T. Choy, H. Chan, Y.T. Zhang","doi":"10.1109/IEMBS.1995.579811","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579811","url":null,"abstract":"Intuition would suggest that any additional mass caused by carcinoma in the lungs should change the overall eigen system of the thorax in resonance. To confirm this the authors undertook measurements on several carcinoma patients to ascertain whether this is indeed the case. They present two cases in which one can observe this suspected behaviour without the problems of associated fluid or other conditions masking the effect one wishes to study. The authors have noted that usually only directly above the carcinoma site does any significant difference appear in the spectral response thus suggesting that carcinomas may generate an acoustical shadow. However, the authors conclude that further research is required before this can be used in any clinical sense.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"65 1","pages":"1529-1530 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79057580","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A combined method for the detection of ventricular fibrillation 一种联合检测心室颤动的方法
G. Sierra, A. Cabrera, A. Martínez-Rubio, L. Reinhardt, T. Fetsch, S. Yli-mayry, K. Balkenhoff, G. Breithardt
{"title":"A combined method for the detection of ventricular fibrillation","authors":"G. Sierra, A. Cabrera, A. Martínez-Rubio, L. Reinhardt, T. Fetsch, S. Yli-mayry, K. Balkenhoff, G. Breithardt","doi":"10.1109/IEMBS.1995.575141","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575141","url":null,"abstract":"A combined algorithm is proposed for the detection of ventricular fibrillation and its accurate discrimination from other rhythms. A total of 95 sinus rhythms, 15 monomorphic ventricular tachycardias, 33 atrial fibrillations, 39 supraventricular tachycardias and 30 ventricular fibrillations were analyzed. The algorithm tests three characteristics of the ventricular fibrillation through the estimation of the isoelectric potential, the power spectrum and the coherence spectrum. The algorithm allowed a reliable distinction of ventricular fibrillation from the other rhythms. The aim of this algorithm is to be used in any external device processing surface ECG signals.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"3 1","pages":"343-344 vol.1"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79458874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Microemboli characterization by determination of Legendre coefficients of phase function 测定相函数的勒让德系数表征微栓子
Jungkuk Kim, J.C. Lin, L. Reynolds
{"title":"Microemboli characterization by determination of Legendre coefficients of phase function","authors":"Jungkuk Kim, J.C. Lin, L. Reynolds","doi":"10.1109/IEMBS.1995.579889","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579889","url":null,"abstract":"The characterization of microemboli located in whole blood is attempted by determining the Legendre coefficients of phase function from the scattered light distribution around the medium. In the radiative transport equation, a microembolus is represented as a secondary source and assumed to have a spherical form and the first order transport approximate solution of the equation is used to describe the scattered intensity distribution. After the scattered intensities are determined at the surfaces of the medium, the orthogonal property of Legendre polynomial is used to extract the coefficients out of the intensities. From the obtained coefficients, the size and complex index of refraction of microemboli are determined.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"61 1","pages":"1681-1682 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79589067","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A neural network based approach to whitening biological noise for somatosensory evoked potential detection 基于神经网络的体感诱发电位检测生物噪声美白方法
D.B. Smith, D. Lovely
{"title":"A neural network based approach to whitening biological noise for somatosensory evoked potential detection","authors":"D.B. Smith, D. Lovely","doi":"10.1109/IEMBS.1995.575371","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575371","url":null,"abstract":"A matched filter is the optimal technique for detecting a known signal buried in additive white noise. Surface recorded somatosensory evoked potentials are corrupted with non-white noise, and so must be whitened before being passed to a matched filter. The authors evaluated the viability of selected artificial neural networks in whitening the noise of recorded evoked potentials.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"38 1","pages":"803-804 vol.1"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83229960","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Parameter estimation of a physiological model for heat exchange during cardio-pulmonary bypass 体外循环过程中热交换生理模型的参数估计
D. R. Carta
{"title":"Parameter estimation of a physiological model for heat exchange during cardio-pulmonary bypass","authors":"D. R. Carta","doi":"10.1109/IEMBS.1995.579760","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579760","url":null,"abstract":"A model describing relations and interactions between local vessel resistances and tissue temperatures during extra-corporeal circulation (ECC) is described and developed from first principles. Unknown model parameters are estimated by means of an extended Kalman Filter from real patient data. Estimated model parameters produced good model performance in tracking patient data and produced meaningful physiological results. This approach is a necessary first step in modeling further physiological interactions in the body during hypothermic ECC.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"73 1","pages":"1427-1428 vol.2"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83357631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Comparison of gradient descent and conjugate gradient learning algorithms for classification of electrogastrogram 梯度下降算法与共轭梯度学习算法在胃电图分类中的比较
Zhiyue Lin, J. Maris, L. Hermans, J. Vandewalle, J. De, Z. Chen
{"title":"Comparison of gradient descent and conjugate gradient learning algorithms for classification of electrogastrogram","authors":"Zhiyue Lin, J. Maris, L. Hermans, J. Vandewalle, J. De, Z. Chen","doi":"10.1109/IEMBS.1995.575378","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575378","url":null,"abstract":"Our previous study showed that the possibility of using an optical three-layer feedforward neural network employing the gradient descent learning algorithm for automated assessment of normality of the electrogastrogram. However, problems with this algorithm are slow convergence rate and critical user-dependent parameters. In the present study, two conjugate gradient learning algorithms (quasi-Newton and scaled conjugate algorithm) were introduced and compared with the gradient descent learning algorithm for the classification of the normal and abnormal electrogastrogram. Three indexes, the convergence rate, complexity per iteration and parameter robustness, were used to evaluate the performance of each algorithm. The results showed that the scaled conjugate gradient algorithm performed the best, which was robust and provided a super linear convergence rate.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"65 1","pages":"817-818 vol.1"},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83374808","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信