A.L. Tagle, J. V. Santander, H. A. Garcia, S. Cortez
{"title":"Restoration of cyclone damaged transmission lines in Mexico","authors":"A.L. Tagle, J. V. Santander, H. A. Garcia, S. Cortez","doi":"10.1109/TDCLLM.1995.485047","DOIUrl":"https://doi.org/10.1109/TDCLLM.1995.485047","url":null,"abstract":"Comision Federal de Electricidad (CFE) is the principal provider of electricity in Mexico, which is located in one of six regions in the world subject to intense tropical storms. Since it is not economically feasible to design power transmission lines to withstand the extreme loadings that these storms bring, CFE has developed a plan of action for rapid restoration. This paper gives an overview of this plan as well as a recent example of its implementation.","PeriodicalId":197796,"journal":{"name":"Proceedings of ESMO'95 - 1995 IEEE 7th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131234531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Aging of porcelain suspension insulators under mechanical and electrical stress on EHV AC lines","authors":"A. Jagtiani, J. Booker","doi":"10.1109/TDCLLM.1995.485040","DOIUrl":"https://doi.org/10.1109/TDCLLM.1995.485040","url":null,"abstract":"A small number of failures of standard porcelain suspension insulators used on American Electric Power Company's (USA) 765 kV lines were found with the porcelain shed broken away from the cap and pin assembly, allowing a \"donut\" of porcelain to fall to the hardware below. The investigation of these failures was approached from many angles to determine the sequence of events leading to the failure. Additionally, it was desired to determine if this phenomena was the result of aging porcelain under electrical and/or mechanical stress.","PeriodicalId":197796,"journal":{"name":"Proceedings of ESMO'95 - 1995 IEEE 7th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1995-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133213700","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transmission towers inventory","authors":"V. Kogan, R. Gursky","doi":"10.1109/TDCLLM.1995.485037","DOIUrl":"https://doi.org/10.1109/TDCLLM.1995.485037","url":null,"abstract":"Transmission towers for major lines constitute a critical component because it is undesirable to lose any major transmission lines for longer than a few weeks. Since tower fabrication cannot be accomplished quickly on-demand, it is important to hold an adequate inventory of transmission towers. This paper discusses a statistical procedure to analyze failure data and estimate inventory requirements for transmission towers, using a homogeneous Poisson process model.","PeriodicalId":197796,"journal":{"name":"Proceedings of ESMO'95 - 1995 IEEE 7th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance","volume":"200 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121110463","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Valuation of nonguaranteed energy for the Electricite de France transmission network","authors":"D. Lombardet, A. Kiener","doi":"10.1109/TDCLLM.1995.485035","DOIUrl":"https://doi.org/10.1109/TDCLLM.1995.485035","url":null,"abstract":"This document sets out the method used for the forecast valuation of nonguaranteed energy (and power) induced by the shutdowns of the HV lines of EDFs transmission network. These valuations constitute a guide for the operators regarding the relative importance of the various shutdowns and the interest of implementing different means, these being live line working techniques.","PeriodicalId":197796,"journal":{"name":"Proceedings of ESMO'95 - 1995 IEEE 7th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123130123","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}