{"title":"Failures of MOSFETs in terrestrial power electronics due to single event burnout","authors":"C. D. Davidson, E. Blackmore, J. I. Hess","doi":"10.1109/INTLEC.2004.1401516","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401516","url":null,"abstract":"Failures of semiconductor devices caused by cosmic radiation exposure is well known in space and avionics applications. However it is not well known that similar issues exist, to a lesser extent, for terrestrial applications. We have conducted research into the phenomenon of single event burnout (SEB) of high voltage power electronics semiconductor devices, specifically MOSFETs that are ubiquitously used in modern switchmode power electronics. The research revealed that SEB and related effects, caused by high-energy neutrons generated by the impact of cosmic radiation on our upper atmosphere, are a real possibility at ground level. An introduction and overview of the SEB effect, a review of existing literature indicating the flux and energy distribution of neutrons that reach the earth's surface and an overview of the structure of MOSFET devices indicating why they could be susceptible to the SEB effect is given. Experiments were conducted which demonstrated that random failures of high voltage MOSFET devices, when they are biased in the off state, do occur at a much higher rate than should otherwise be expected. A summary of experiments that were carried out at the TRIUMF cyclotron laboratory on both individual MOSFETs and on electronic equipment containing MOSFETs is presented. These experiments provide strong evidence that failures of MOSFETs and circuits using MOSFETs can be caused by neutrons with energy distributions similar to that experienced on the earth's surface.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115607658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Working with the electricity industry in times of rapid change - a telecomms user's experience","authors":"M. Dixon","doi":"10.1109/INTLEC.2004.1401451","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401451","url":null,"abstract":"The public electricity supply industry in the United Kingdom has been undergoing a period of unprecedented change. Before 1990 the industry was wholly in state hands but since then the industry has been almost entirely privatised and there has been intense activity on the merger and takeover front, with most of the industry now owned by nonUK companies. This has produced a challenging environment for large users of electricity such as British Telecommunications. As one of the largest users of electricity within the UK, it is heavily dependent upon the cooperation of the electricity industry in order to be able to deliver new telecommunications services and meet its own regulatory obligations. A particular problem area is in the provision of new or upgraded electricity supplies to its buildings, where it frequently encounters long delays. The new structure of the industry has also afforded opportunities to large users to save money. One such opportunity is triad avoidance, where money can be saved by deliberately running standby generators to support BT's own load, and thereby take pressure off the national grid system at times of high demand. At BT's largest sites, it is cost effective to run the generators manually, although a new web-based remote access system is being deployed which makes it possible to run these sites remotely. At BT's other sites, it is continuing to deploy a remote alarm and control system which enables remote running of generators, both for routine and triad avoidance running. This paper expands on these and other opportunities and problems encountered in BT's dealings with the UK electricity industry.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116927571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reducing and utilizing electrical noises for battery monitoring purposes","authors":"Z. Noworolski, P. Eng., U. Reskov","doi":"10.1109/INTLEC.2004.1401532","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401532","url":null,"abstract":"The presence of the AC across batteries were known for some time now (Harrison, D., 1984), (Noworolski, Z et al., 1996). D. Wilson presented some results of ripple current in the battery plant (Wilson, D., 1988). Some aspects of impedance measurements with the presence of noises were also reported (DeBardelaben, S.L., 1988). D.H.J Baert, A.A.K Vervaet utilized noises generated by the battery itself for assessment of the state-of health of VRLA batteries (Baert, D.H.J et al., 2001). In this paper, the authors will briefly revive previously published data and concentrate on the application of two types of noises for the purposes of battery health assessment.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115036888","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fall of the dial tone empire: what will happen to thy loyal servant, battery 'n' dirt?","authors":"S. Martín","doi":"10.1109/INTLEC.2004.1401436","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401436","url":null,"abstract":"The 20th century saw the rise of the dial tone empire. Alert and diligent, loyal servant Battery \"n\" Dirt protected emperor dial tone from loss of power. As the 21st Century dawns, soothsayers, prophets, and wizards predict that perhaps half of emperor dial tone's narrowband access lines will perish by 2010. Strong contenders for the throne, including Attila the Wireless and IP telephony barbarians, have emerged from the eastern badlands. Royal treasury depleted, the Empire may be in dire straits. What will happen to thy loyal servant, Battery \"n\" Dirt? Will he be allowed to continue to serve, or will he be deemed too large a burden on the royal treasury? Will he be able to find ways to reduce capital or operational expenditures (CAPEX or OPEX) and thus gain favor with the Emperor? Viable alternatives to wireline plain old telephone service (POTS) are available. DSL and cable modems are rapidly replacing second lines used for internet access. Dial-up internet access will be extinct by 2010. Younger \"Generation Y\" customers are adopting wireless in lieu of wireline. IP telephony is on the doorstep of minimum quality of service (QoS) performance and thus mainstream acceptance. Demand is strong for broadband services, but competition is fierce and margins razor thin. Incumbent local exchange carriers (ILECs) must transform themselves from \"telephone\" to \"information transportation\" companies. ILECs are faced with the daunting task of modernizing a network that is losing customers. What will the \"Central Office of the Future\" look like? Will more or less floor space, power, and HVAC be required? The purpose of this paper is to attempt to answer this question and then investigate strategies to reduce CO power CAPEX and OPEX requirements.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122403558","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modeling and performance studies of a fuel-cell powered boost converter","authors":"D. Yu, S. Yuvarajan","doi":"10.1109/INTLEC.2004.1401549","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401549","url":null,"abstract":"The proton exchange membrane (PEM) fuel cell is becoming popular as an alternate power source for various applications. The paper presents a novel circuit model for a PEM fuel cell that can be used to design and analyze fuel-cell power system. The PSPICE-based model uses BJTs and LC elements available in the PSPICE library with some modification. The static and dynamic characteristics obtained through simulation are compared with experimental results obtained on a commercial fuel-cell module. The possibility of operating the fuel cell at its maximum power point is investigated. The performance of the fuel cell module when feeding a boost converter is studied through simulation and experiment and the waveforms are presented. The need for a buffer capacitor to make up for the voltage drop under transient switching operation is established.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129857223","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Xingkuan Guo, Xiaojun Deng, J. Zeng, Jianping Ying
{"title":"Analysis and solution to voltage unbalance of the flying capacitor in ZVS three-level DC/DC converter","authors":"Xingkuan Guo, Xiaojun Deng, J. Zeng, Jianping Ying","doi":"10.1109/INTLEC.2004.1401545","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401545","url":null,"abstract":"In order to lower the voltage stress on power devices, the three-level topologies are widely used in high voltage converters. In the topologies a flying capacitor is added to achieve true ZVS under phase shift control. But the ZVS three-level converter will run abnormally at light load if the flying capacitor is added. The main issue is the charge unbalance across the flying capacitor. Due to the unbalance, the voltage stress on the switches of lagging leg becomes high so much as 500 V under 800 V bus condition. This issue will also appear under open voltage loop condition (this condition may occur in dynamic load). Aiming at this issue, the reason of charge unbalance of the flying capacitor is firstly analyzed under the light load and open voltage loop in this paper. An experiment is implemented for testifying the analysis. A novel method is presented for this issue. This method not only effectively balances the charge of the capacitor but also is lossless.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"118 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116370049","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High-performance induction generator-wind turbine connected to utility grid","authors":"M. Orabi, F. El-Sousy, H. Godah, M. Youssef","doi":"10.1109/INTLEC.2004.1401547","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401547","url":null,"abstract":"This work proposes a wind generation system connected to a grid using self-excited induction generator (SEIG). The stator currents of the induction generator (IG) are optimally controlled using indirect orientation control (IFOC) according to the generator speed in order to maximize the generated power from the wind turbine. The IG is controlled by the maximum power point tracking (MPPT) below the base speed and the maximum energy can be captured from the wind turbine. The paper presents an IFOC for IG with rotor flux to maintain the DC-link voltage at constant value. During voltage buildup, the variation of the magnetizing inductance is taken into consideration. The DC-link power is transferred to the gird via inverter with vector control. By using the vector controller and the synchronous frame current regulators both the input and output currents of the integrated system are characterized with fast current response and low harmonic distortion. The complete system has been simulated with different wind velocities. The simulation results show the effectiveness of the proposed MPPT wind energy system.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130825908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of the relationship between conductance and capacity measurements of VRLA batteries in Brazil","authors":"R. F. Beck, M. Rosolem, P.E.R. Cardoso, L. Soares","doi":"10.1109/INTLEC.2004.1401529","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401529","url":null,"abstract":"Since 1996 CPqD has been studying the application of conductance and impedance techniques to evaluate the degree of degradation of stationary lead acid batteries. The conductance technique has becoming a popular technique in Brazilian's telecommunications companies since 2002, and a very frequent question is: - which is the relationship among measurements of conductance and capacity? In order to clarify this question we decided to make some experiments. In these experiments the charge/discharge cycles was accelerated, each one composed by 23 hours of charge and a discharge at C/sub 1/, (until that the voltage of the last cell has reached 1,75 V). This experiment was done with three VRLA AGM (absorbed glass material) cells. In each cycle the conductance of each cell was measured before beginning the discharge, and the experiment was conducted until two cells reached a capacity below 50% of the nominal value. This paper reports the results obtained in accelerated life cycle testing, the relationship between conductance and capacity, the number of cycles supported by each cells, and a determination whether it is possible or not to estimate the capacity through conductance measurements.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132858355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Common mode noise modeling and analysis of dual boost PFC circuit","authors":"Haoyi Ye, Zhihui Yang, Jingya Dai, Chao Yan, Xiaoni Xin, Jianping Ying","doi":"10.1109/INTLEC.2004.1401526","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401526","url":null,"abstract":"To achieve high efficiency PFC front stage in switching mode power supply (SMPS), dual boost PFC (DBPFC) topology shows superior characteristics compared with traditional boost PFC, but it by nature brings higher EMI noise, especially common mode (CM) noise. This paper deals with the modeling and analysis of DBPFC CM noise based on and compared with boost PFC, noise propagation equivalent circuits of both topologies are deduced, and theoretical analysis illustrates the difference. Experiments are performed to validate the EMI model and analysis.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114372327","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The round cell: promises vs. results 30 years later","authors":"A. Cannone, W. Cantor, D. Feder, J.P. Stevens","doi":"10.1109/INTLEC.2004.1401500","DOIUrl":"https://doi.org/10.1109/INTLEC.2004.1401500","url":null,"abstract":"In the late 1960's Bell Laboratories developed a novel cylindrical design for a stationary reserve lead acid battery to provide back-up power in the Bell Telephone System's central offices. The extensive laboratory test and evaluation data suggested that this design should significantly extend the expected life and reduce maintenance in telephone float service vs. conventional designs available at that time. Limited commercial production of this design was initiated in 1972, with full-scale production at two manufacturers underway by 1974. To date more than 1.5 million cells have been made, installed and used by the divested telecom heirs to their Bell System forefathers, as well as nonBell companies. Actual discharge test, field inspection and overall performance evaluation results are presented on more than 14,000 individual round cells, ranging from less than one to more than 24 years in service. Round cell string capacity tests show a level trend with no string failures for the full 24-year period. Individual round cell tests of the 14,568 round cell population indicate a worst case failure rate of 19 round cells in the 14,568 cell population, or 0.1% failure. Eliminating cells of questionable suitability (not recharged, etc.) results in a failure rate of only 2 cells of the 14,551 remaining round cell population, or 0.01% failure. The 1970's accelerated tests had projected plate growth to reach only 2% in 70 years. Plate growth data from round cells removed from field service for 7, 15 and 23 years appear to confirm that projection. The data also indicates zero post seal or jar cover seal leakage in any of the more than 14,000 round cells tested, in stark contrast to the traditional field expectations of post seal and jar/cover seal leakage in either rectangular flooded or valve regulated lead acid (VRLA) cell designs. An actual post seal leakage rate of 4 to 10 percent was found on the more than 28,000 rectangular flooded cell population tested. Capacity test results on the >14,000 VRLA cell test population follow results of other recent publications. VRLA average string capacities trend linearly downward with age, reaching 80% in only 5 years. This study lends further credence to what appeared at the time to be exorbitant promises of the 1970's with regard to both reduced capacity aging and grid growth rates. This study also reports a zero rate of post seal and jar/cover seal leakage, unique in the industry.","PeriodicalId":192956,"journal":{"name":"INTELEC 2004. 26th Annual International Telecommunications Energy Conference","volume":"120 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116368290","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}