2014 16th International Conference on Harmonics and Quality of Power (ICHQP)最新文献

筛选
英文 中文
Keynote speech 主旨演讲
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2021-08-01 DOI: 10.1145/1229285.1229287
M. Bregman
{"title":"Keynote speech","authors":"M. Bregman","doi":"10.1145/1229285.1229287","DOIUrl":"https://doi.org/10.1145/1229285.1229287","url":null,"abstract":"GENERASI baru yang terdidik secara baru melahirkan kesadaran baru, bahwa nasib rakyat tidak bisa digantungkan dengan cuma mengandalkan pada impian ratu adil. Kesadaran baru itu menyeruak di seputar 28 Oktober 2007 lalu, atau lebih tepatnya pada momentum menyongsong peringatan 100 tahun Kebangkitan Nasional dan 80 tahun Sumpah Pemuda, dengan mengibarkan jargon “saatnya kaum muda memimpin” lewat jargon yang lain: “jalan baru, pemimpin baru” .","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133518822","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Power quality assessment for autonomous residential PV systems 自主住宅光伏系统电能质量评价
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-06-26 DOI: 10.1109/ICHQP.2014.6842897
C. Christodoulou, N. Papanikolaou, I. Gonos
{"title":"Power quality assessment for autonomous residential PV systems","authors":"C. Christodoulou, N. Papanikolaou, I. Gonos","doi":"10.1109/ICHQP.2014.6842897","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842897","url":null,"abstract":"The power quality of three phase autonomous residential PV systems is examined in terms of compatibility with the relevant international standards. An insightful sensitivity analysis takes place, highlighting the contribution of the operational variables to the system power quality.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131624803","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
The effect of using isolation transformers to supply small nonlinear loads 用隔离变压器供电小非线性负载的效果
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-06-26 DOI: 10.1109/ICHQP.2014.6842781
M. Costea, T. Leonida
{"title":"The effect of using isolation transformers to supply small nonlinear loads","authors":"M. Costea, T. Leonida","doi":"10.1109/ICHQP.2014.6842781","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842781","url":null,"abstract":"It is well known that between other non-linear loads the IT and office equipment or measuring equipment are important sources of current harmonics. There are particular cases when equipment of this type are supplied through isolation transformers such as equipment dedicated for interface between a high voltage laboratory and its control room or medical equipment. In the first step it was analyzed the influence of voltage level upon current harmonic content in the case of desktop computers and cathode ray tube monitors directly connected to the network. The main parameters were recorded using a professional power quality analyzer. The effect of an isolation transformer used to supply the same consumers was then evaluated. In particular situations, the use of isolation transformer diminishes the current harmonics injected in the supply network.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134620217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The superposition of the random harmonic phasors based on the cloud model 基于云模型的随机谐波相量叠加
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-06-26 DOI: 10.1109/ICHQP.2014.6842790
Bo Tang, Shiwei Ma, Guang Chen, Yu Lu, Shunfu Lin
{"title":"The superposition of the random harmonic phasors based on the cloud model","authors":"Bo Tang, Shiwei Ma, Guang Chen, Yu Lu, Shunfu Lin","doi":"10.1109/ICHQP.2014.6842790","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842790","url":null,"abstract":"A novel method based on the cloud model for the superposition of the distributed random power harmonics is presented in this paper. Three characteristic quantities (Ex, En and He) of the measured harmonic phasors are calculated by the cloud model inverse generator. The probability density function described by the cloud model is presented to obtain the 95% probability value of the harmonics. Field tests results prove that the presented method has a good performance even with small volume of samples, which does not need the particular probability distribution of each random phasor.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127622526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Solutions to optimize energy consumption of airblowers by monitoring oxygen levels in the bioreactor 通过监测生物反应器中的氧气水平来优化鼓风机能耗的解决方案
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-06-26 DOI: 10.1109/ICHQP.2014.6842816
Panaitescu Ileana-Irina, Panaitescu Fanel-Viorel, P. Mariana
{"title":"Solutions to optimize energy consumption of airblowers by monitoring oxygen levels in the bioreactor","authors":"Panaitescu Ileana-Irina, Panaitescu Fanel-Viorel, P. Mariana","doi":"10.1109/ICHQP.2014.6842816","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842816","url":null,"abstract":"The paper deals with the analysis of energy consumption and power quality in wastewater treatment plants, during the operation of air blowers optimized for monitoring the level of oxygen in the bioreactor. The airblowers' consumption is over 68% in energy consumption of wastewater treatment plant. This consumption optimization was done using sensors of the level of oxygen in the bioreactor that partial closure for command of airblowers, maintaining oxygen levels between 1.5 and 2.5%. By closing the discharge of airblowers it reduce the air flow, the rotation frequency of airblower and its consumption. The current absorbed during the operation of these airblowers shows important harmonics.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126610214","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Real-time simulations of a parallel hybrid active filter with hardware-in-the-loop 硬件在环并联混合有源滤波器的实时仿真
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-05-25 DOI: 10.1109/ICHQP.2014.6842804
L. Herman, A. Božiček, B. Blazic, I. Papič
{"title":"Real-time simulations of a parallel hybrid active filter with hardware-in-the-loop","authors":"L. Herman, A. Božiček, B. Blazic, I. Papič","doi":"10.1109/ICHQP.2014.6842804","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842804","url":null,"abstract":"This paper presents hybrid power filter (HPF) performance evaluation procedure by applying special simulation hardware for digital real-time power system simulation (RTDS). RTDS simulator enables real-time calculation of electromagnetic phenomena with calculation time step of even 1-2 μs. Special hardware makes possible of importing and exporting of electrical signals from the simulator to external equipment and therefore so called hardware-in-the-loop (HIL) testing. Such simulations provide an insight in the equipment behaviour and also the influence of this equipment to system operation. In this paper a combination of a three-phase, two-level, voltage-source converter connected in parallel with the inductor of a shunt, single-tuned, passive filter is tested. To control the active part, a proportional-resonant (PR), multi-loop controller is used. The testing has shown a remarkable usefulness of the RTDS simulator for determination of actual electrical system equipment behaviour in various system conditions.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115381269","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
The implementation of correct reactive power measurement is long overdue 正确的无功功率测量早就该实施了
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-05-25 DOI: 10.1109/ICHQP.2014.6842751
Tan Zhang, S. Cialdea, A. Emanuel, J. Orr
{"title":"The implementation of correct reactive power measurement is long overdue","authors":"Tan Zhang, S. Cialdea, A. Emanuel, J. Orr","doi":"10.1109/ICHQP.2014.6842751","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842751","url":null,"abstract":"The scope of this study is two fold: first, it advocates the recognition of the 60/50 Hz, positive-sequence reactive power as the significant reactive power component of apparent power. This nonactive component must be monitored in the same way that the 60/50 Hz active power is monitored under nonsinusoidal conditions. Secondly, this paper documents the fact that instrumentation used today for reactive power measurement is marred by a significant difference between the indicated reactive power and the correct 60/50 Hz reactive power. Regrettably, such instrumentation is still favored by many utilities, instrumentation manufacturers and supervisors of energy markets. This paper documents a wide spectrum of situations that shed light on the discrepancies between the correct value of the reactive power and the measured value.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"127 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116945161","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Twelve-pulse multilevel current source inverters for fundamental frequency switching schemes 用于基频开关方案的十二脉冲多电平电流源逆变器
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-05-25 DOI: 10.1109/ICHQP.2014.6842844
Simon Koenig, G. Herold
{"title":"Twelve-pulse multilevel current source inverters for fundamental frequency switching schemes","authors":"Simon Koenig, G. Herold","doi":"10.1109/ICHQP.2014.6842844","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842844","url":null,"abstract":"Due to several reasons current source inverters (CSI) are seldom used compared to the voltage source inverter (VSI) principle. On the one hand they need reverse blocking semiconductors, on the other hand their DC-link element is an inductor. Furthermore the topology is affected by the unavoidable resonant behaviour of its output network because of the necessary output capacitors. Until now all efforts to avoid the excitation of this resonance were switching scheme based. This paper provides the time domain solution for a twelve-pulse topology that is by its principle able to avoid the lowest order harmonics and can therefore be operated with every switching scheme, even fundamental frequency ones.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"156 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121260944","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Rate of change of frequency - a power quality descriptor 频率变化率——电能质量描述符
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-05-25 DOI: 10.1109/ICHQP.2014.6842900
M. Albu, A. Dumitrescu, R. Popovici
{"title":"Rate of change of frequency - a power quality descriptor","authors":"M. Albu, A. Dumitrescu, R. Popovici","doi":"10.1109/ICHQP.2014.6842900","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842900","url":null,"abstract":"The smart grids paradigm includes newly defined real time control strategies, and therefore detailed models for the energy transfer are required together with new algorithms for information retrieval. Although today measurement infrastructure (including the high reporting rate measurement devices, like Phasor Measurement Units) is capable to give insight to such details, the measurement information has to be structured in a new way. Moreover, new quantities - like rate of change of frequency - rocof - become relevant for both monitoring and control purposes. Presently there are in use aggregation algorithms inherited from power quality standards like the IEC 61000-4-30 set, but no algorithm is yet specified for rocof reporting. In this paper is presented a discussion of the time- and space- aggregation of frequency (including its rate of change) using phasor data concentrators' framework.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121345374","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Elimination of subharmonics in spectra of output voltage of drive inverters with space-vector PWM 空间矢量PWM消除驱动逆变器输出电压谱中的次谐波
2014 16th International Conference on Harmonics and Quality of Power (ICHQP) Pub Date : 2014-05-25 DOI: 10.1109/ICHQP.2014.6842766
V. Oleschuk, V. Ermuratskii, V. Berzan
{"title":"Elimination of subharmonics in spectra of output voltage of drive inverters with space-vector PWM","authors":"V. Oleschuk, V. Ermuratskii, V. Berzan","doi":"10.1109/ICHQP.2014.6842766","DOIUrl":"https://doi.org/10.1109/ICHQP.2014.6842766","url":null,"abstract":"The paper describes methods and techniques of synchronized space-vector pulsewidth modulation (PWM), providing symmetry (quarter-wave symmetry and/or half-wave symmetry) of the output voltage waveforms of modulated voltage source inverters for adjustable speed drives. In this case spectra of symmetrical output voltage of inverters do not contain subharmonics (of the fundamental frequency), which are very undesirable in motor drives, especially in systems with low switching frequency of inverters. Both standard approach and novel space-vector-based approach can be used for elaboration of algorithms of synchronized modulation of drive inverters. It has been shown, that novel methods and techniques of synchronized PWM provide symmetry of the output voltage of inverters (and cancellation of subharmonics from voltage spectra) at both undermodulation and overmodulation control modes of drive inverters, and for any ratio (integer or fractional) between the switching frequency and fundamental frequency.","PeriodicalId":188461,"journal":{"name":"2014 16th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"159 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126757253","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书