{"title":"Discharge detection and measurement in voids in solid dielectrics","authors":"A. Nosseir, M. Salama, A. Soliman, M. Rizk","doi":"10.1109/EIC.1984.7465211","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465211","url":null,"abstract":"Insulating systems invariably contain some cavities or voids entrained within the insulation or at boundaries between dielectric and conductors. The paper presents experimental results obtained in an investigation of the factors affecting the discharge characteristics in voids in solid dielectrics. An E.R.A. discharge detector was used for detection and measurement of discharge magnitudes. The dependency of the discharge magnitude in voids on; the applied voltage, the void dimensions and the duration of the applied voltage was investigated experimentally. Test results also indicate that the discharge magnitude-applied voltage characteristics exhibit same hysterisis. This hysterisis effect is more pronounced for deeper cavities.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122873068","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"High field dielectric dissipation factor of polyethylene","authors":"M. Kosaki, T. Tokoro, M. Nakamori, M. Nagao","doi":"10.1109/EIC.1984.7465153","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465153","url":null,"abstract":"The dielectric dissipation factor of polyethylene films has been measured as functions of electric field, frequency and temperature. The dissipation factor increases with electric field gradually, which may be attributed to the carrier transport process. The curve of dissipation factor vs. temperature at 100Hz has two absorption peaks for low density polyethylene films. The peak in the low temperature side may be due to the dielectric relaxation of carbonyl groups in side chains and the high temperature peak to the interfacial polarization. The dissipation factor enhanced by electric field decreases with time of the electric field application which may be caused by both the morpholgical structure and electrical conductivity changes of the sample.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131531803","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The analysis of partial discharge activity by microprocessor-based instrumentation","authors":"A. Millar, I. Kemp, R. D. Pringle","doi":"10.1109/EIC.1984.7465214","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465214","url":null,"abstract":"This report introduces a new approach to the collection statistical analysis and presentation of data relating to partial discharge activity within solid insulation systems used in major items of plant within the electricity supply industry. The authors briefly discuss present methods of discharge testing, explain the requirements for a new approach and present design details of a microprocessor-based instrument for use in diagnostic testing. Comment is made on the proposed application of this instrument to testing items of electrical plant and small samples of solid insulation. In conclusion the authors claim that the use of an instrument, capable of simultaneously measuring and calculating multiple discharge parameters, enables the condition of any given insulation system to be more fully described and the parameters affecting insulation lifetime to be placed in order of importance.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134143985","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Nakabasami, K. Sasaki, K. Sugiyama, M. Ishitobi
{"title":"Development of XLPE cable with new laminated waterproof layer","authors":"T. Nakabasami, K. Sasaki, K. Sugiyama, M. Ishitobi","doi":"10.1109/EIC.1984.7465144","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465144","url":null,"abstract":"To avoid water penetrating into cable insulation through jacket two simple structures are considered; one is that the metal laminated tape layer is positioned beneath the jacket, and the other is on the cable core. This paper outlines the former case, which is furnished with a newly developed laminate lead tape layer beneath the PVC jacket. The new laminated lead tape is composed of a semi-conducting PVC layer, lead foil layer and reinforcing plastic layer. This tape was found to be applicable to large-sized cables without any trouble during manufacturing. This XLPE cable with new laminated waterproof jacket was clear to have excellent waterproofness and higher reliability more than the XLPE cable with PVC jacket through long-term test in water immersion and can be used satisfactorily for actual cable lines.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132300667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The cause of tracking-induced abnormal drop in the surface resistance of rubber-made electrical components","authors":"Masayuki Ishiwa, Takahisa Tamura","doi":"10.1109/EIC.1984.7465157","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465157","url":null,"abstract":"It is widely known that the tracking deterioration of high-voltage electric equipment occurs in heavily polluted environments, including the seaside where equipment faces injury from salt. Development of materials always takes these environments into account. This report deals with cases in which rubber-made electrical components that have been used in enclosed environments free of any contamination including injury from salt suffer a rapid drop in their surface insulation resistances, leading to tracking deterioration. It attempts to guess the cause of the deterioration and states measures to improve the rubber composition. Deteriorated components featured an overall wet condition with partial incineration. The reduced insulation resistances on the surface did not recover even after the components were left inside a room for several months, suggesting that the deterioration had not been caused simply by the wet condition. As the most likely cause, attention was paid to possible influence of active gases that are generated by partial discharge. For confirmation, insulation rubber sheets were exposed to active gases generated by ozonizer using air as raw material. Measurement after the exposure revealed a rapid drop in the surface resistances, which did not recover even after the sheets were returned into normal atmosphere. Then, electric wire of small size whose surface resistances had dropped after being exposed to active gas was subjected to a power application test in a highly humid room. In the test, glow-like discharges that were stable in position could be observed continuously. Next, power was applied to untreated pieces of electric wire in an environment in which such discharges were occurring. At the beginning nothing happened, but then the wire began to generate discharge and a drop was observed in its surface resistance. Examination of the compounding ingredients of the rubber composites whose surface resistances had dropped revealed that the drop had been caused by calcium carbonate used as filler and by zinc oxide used as activator. It was assumed that the drop in the surface insulation resistance was caused by the high deliquescent property of the nitrate that was generated in a reaction between the NOx created by discharge and inorganic compounding ingredients blended into the rubber composition. These results showed that in an enclosed wet environment, even when the rubber-made electric component is not polluted at all, discharge caused by some outside factor except the rubber component sometimes lowers the insulation resistance on the rubber surface rapidly, leading to a tracking deterioration in a short period of time. In this case, some kinds of in organic fillers can accelerate the deterioration instead of adding to the tracking resistance. In preventing deterioration of the rubber products used in the said environments. Therefore, it is effective to restrain the points that generate discharge in enclosed environment. And when","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"166 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115275636","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An analysis of insulation ageing of generator stator windings","authors":"K. Matsunobu, F. Aki, K. Kadotani","doi":"10.1109/EIC.1984.7465192","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465192","url":null,"abstract":"The ‘D Map’ expression for insulation diagnosis was revised to fit for actual large generator windings with transposition of conductors.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123514063","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Three types of partial discharges in electrical insulation","authors":"N. Izeki, F. Tatsuta","doi":"10.1109/EIC.1984.7465209","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465209","url":null,"abstract":"This paper describes measured results of three types of partial discharges - OPD, SPMD and PLPD -, and gives some consideration on their mechanisms. In addition, it introduces the measuring principle and features of Lissajous figure method to analyze the PD mechanisms.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130664240","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The effect of thin insulating barrier on the electric strength of liquid nitrogen subjected to highly diver gent fields","authors":"J. Fleszyński, J. Rutkowski, A. Tymań","doi":"10.1109/EIC.1984.7465203","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465203","url":null,"abstract":"The results of investigations of the effect of kraft paper or polyester film barriers on the breakdown of liquid nitrogen /LN2/ in highly divergent fields are reported.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124429324","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Kawahara, T. Yoshimitsu, Y. Ishikawa, H. Akahori, Hiroshi Yoshida
{"title":"The effect of temperature on the electrical breakdown voltage of XLPE in the presence of water trees","authors":"K. Kawahara, T. Yoshimitsu, Y. Ishikawa, H. Akahori, Hiroshi Yoshida","doi":"10.1109/EIC.1984.7465142","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465142","url":null,"abstract":"This paper discusses the effects of temperature on the electrical breakdown voltage when water trees are present, as well as the characteristics of XLPE containing only microvoids filled with water. Research indicates that there are two regions in which the effects of temperature may be seen in the presence of water trees, one being the range from 20 °C to 60 °C, and the other from 60 °C to 90 °C. In the lower range, the breakdown voltage remains nearly constant at any range, but the value itself is relatively low compared with the breakdown voltage of XLPE which contains only microvoids. In the higher range, 60 °C – 90 °C, the breakdown voltage increases as temperature rises. This is interesting in view of the fact that the breakdown stress in the original XLPE decreases as temperature increases.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128700357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Recent progress in understanding water treeing phenomena","authors":"B. Bernstein","doi":"10.1109/EIC.1984.7465138","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465138","url":null,"abstract":"Several areas where recent progress has occurred in understanding water treeing are reviewed; propagation rate evaluations, distinguishing between initiation and propagation, the influence of antioxidant and voltage stabilizers, and evaluating clustered water. The necessity for distinguishing between initiation (which encompasses the induction period) and prop gation events is emphasized. Some commonalities in pre-partial discharge events for both electrical and water treeing are suggested, along with a definition of tree initiation. Potential roles of antioxidant and water on tree initiation are reviewed. The possibility of antioxidant clusters serving as pro-oxidants rather than anti-oxidants are also discussed.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"364 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114528083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}