{"title":"Humidity effects on the time-to-breakdown characteristics of a 1-metre gap under positive switching impulse voltages","authors":"J. Kuffel, R. V. van Heeswijk","doi":"10.1109/EIC.1984.7465186","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465186","url":null,"abstract":"A study was carried out on the effect of atmospheric conditions on the time-to-breakdown characteristics of a 1-metre gap under positive switching impulse voltages. Variations in both the volt time curve, and in the statistical time-to-breakdown distributions were examined.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127207349","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electric charge accumulation on HVDC insulators in compressed-SF6-insulated transmission lines","authors":"R. Wootton","doi":"10.1109/EIC.1984.7465182","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465182","url":null,"abstract":"This paper describes measurements of the magnitude and distribution of residual fields around a tri-post insulator in compressed SF6, after being subjected to sustained dc voltages of several hundred kV, of negative and positive polarity. The effects of geometry associated with insulator leg fittings, particle-trap slots and residual dust were studied. Comparative measurements were also made on an annular polyethylene insulator in the same coaxial system, and on uniform thickness disks of polyethylene and filled-epoxy resin in both uniform and non-uniform fields in air. The decay of the residual field involved (in some cases) field reversal leading to the conclusion that some part of field measured initially was due to a slow polarization or bulk charging of the dielectric rather than conduction through and/or over the surface of the insulator and drift of ions through the gas. This work was carried out under Department of Energy Contract DE-AC01-79ET-29059 for the design of a ±600kVdc gas insulated transmission line.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123784874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Volt-time characteristics of rod-sphere gaps in gas mixtures comprising SF6, C-C4F8,-CO AND DRY AIR, -SF6","authors":"S. Okabe, E. Kuffel","doi":"10.1109/EIC.1984.7465165","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465165","url":null,"abstract":"Volt-time characteristics of rod-sphere gaps were measured in gas mixtures comprising 59% SF<inf>6</inf> + 1% C-C<inf>4</inf>F<inf>8</inf> + 40% CO (buffer gas) and 99% dry air + 1% SF<inf>6</inf>. The experimental pressures used were 400 KPA and 500 KPA (abs.) and the gap lengths included 5mm, 10mm, 15mm, 20mm and 25mm. The tests were conducted under both polarity standard impulses, 20/1000µs, 80/1200µs, and 250/1700µs switching surges. Under certain pressure and polarity conditions with time lags less than 1 µs and breakdowns occurring on the impulse wave front the breakdown strength decreased with increasing the rate of rise of voltage.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122872863","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Zahn, Y. Ohki, J. Gottwald, K. Rhoads, M. Lagasse
{"title":"Effects of electrode material on charge injection, transport, energy storage and dissipation in highly purified water","authors":"M. Zahn, Y. Ohki, J. Gottwald, K. Rhoads, M. Lagasse","doi":"10.1109/EIC.1984.7465204","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465204","url":null,"abstract":"Extensive Kerr electro-optic field mapping and voltage/current measurements have been taken with highly purified water over the temperature range of T=0–30°C using parallel plane electrodes with average field strengths up to 160kV/cm. The Kerr constant of water B was measured to be B≃3.4–3.6×10−14m/V2 for free space light wavelength of 590nm and only slightly varies with temperature over the measurement range. For a step high voltage, there is no volume space charge at t=0+. For times greater than 500µs, stainless steel and copper electrodes generally inject positive charge, although under some conditions with mixed electrodes they injected negative charge; aluminum electrodes only inject negative charge; while brass electrodes can inject either positive or negative charge. Thus, by appropriate choice of electrode material combinations and voltage polarity, it is possible to have uncharged water, unipolar charged negative or positive, or bipolar charged water. Generally, the bipolar case allows a higher applied voltage without breakdown, presumably due to the lower electric field strengths at the electrodes due to the space charge shielding. Although injected space charge increases the stared electric energy over the capacitive space charge free energy, (1/2)Cv2, for ohmic conduction the energy delivered to a resistive load is reduced because of internal dissipation in the capacitor. Volume space charge makes no contribution to the load energy but increases the dissipation in the capacitor.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"121 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114544407","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study of the compatibility of polypropylene films with new impregnants for capacitors","authors":"G. Metzger, A. Vicaud","doi":"10.1109/EIC.1984.7465172","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465172","url":null,"abstract":"The consideration given during the last years to the protection of the environment has condemned at a more or less long term the utilization of non biodegradable products. The polychlorinated biphenyls (P.C.B) used as impregnants in power capacitors belong to this category. Some replacement solutions have been studied by industrial producers or users of P.C.B., and new impregnants have become available on the market already since several years.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128384614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"HVDC flashover on the surface of conductive ice","authors":"H. T. Bui, L. Phan, C. Huraux, J. Pissolato","doi":"10.1109/EIC.1984.7465154","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465154","url":null,"abstract":"For a generalized and systematic study of the flashover performance of iced insulators, we investigated the flashover characteristics of HVDC iced insulators on a physical model with different ice temperatures. Iced insulator was simulated by a frozen electrolyte channel connected to the low voltage electrode. HV electrode, made of tungsten, is at an adjustable distance above the electrolyte. Investigation was done in a small refrigerated chamber in which temperature can be obtained at any desired value between 20°C and −50°C. Results show that discharge characteristics do not change with temperature and the flashover voltage obtained with positive polarity is slightly higher than that obtained with negative polarity for high-resistivity liquids. Furthermore with relatively high resistivity liquids (r≥20 kΩcm−1) during icing period (decreasing temperature from 0° to −40°C) the ice resistance is higher than that measured during de-icing period (increasing temperature from −40°C to 0°C) therefore the minimum flashover voltage is lower in the latter case. At −40°C and below it is unlikely to have flashover on ice because ice resistivity is excessively large. Flashover voltage on ice covered with water film is always lower than that obtained with “dry” ice. In the case of uniform voltage stress of our experimental conditions the combination of both de-icing and water-film conditions of ice leads to worst possible situation.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114099837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of a dielectric barrier on the dc and ac breakdown strength of a point-to-plane gap in air","authors":"P. A. Bruyn, R. V. van Heeswijk","doi":"10.1109/EIC.1984.7465187","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465187","url":null,"abstract":"The breakdown voltage of an air insulated nonuniform field gap can be increased by placing a barrier, i.e. a plane sheet of insulating material, between the electrodes normal to the gap axis. This paper reports on the results of an experimental study of the influence of the location of a barrier on the breakdown voltage of a number of point-to-plane gap lengths, stressed with dc voltage of both polarities and 60 Hz ac voltage. The effect of a barrier on the ac corona current and the influence of the area of the barrier surface on the magnitude of the breakdown voltage were also studied. The results show that instead of enlarging insulation clearances in equipment with non-uniform electric fields, the application of a barrier may be a practical alternative.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134353902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dielectric breakdown of polypropylene film in high temperature region","authors":"M. Nagao, M. Kosaki, I. Sugiyama, M. Ieda","doi":"10.1109/EIC.1984.7465174","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465174","url":null,"abstract":"Dielectric breakdown of polypropylene film with d.c. voltage was studied mainly in high temperature region. Above room temperature a thermal breakdown process is considered as a possible breakdown mechanism for the epoxy resin molded specimen and a thermal breakdown process combined with an electromechanical deformation for the non molded one.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130553510","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Axial discharge degradation of mica","authors":"A. J. Shields, G. H. Curtis, I. Kemp","doi":"10.1109/EIC.1984.7465213","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465213","url":null,"abstract":"This paper reports the initial results of a large investigation of the discharge degradation of mica. In this instance, two grades of mica, amber phlogopite and ruby muscovite have been investigated in air and nitrogen under a.c., d.c. and impulse stress conditions. All samples, following discharge degradation, were examined by optical and scanning electron microscopy and chemically analysed. Results indicate that above a critical discharge level breakdown may occur through surface discontinuities by a surface charge field effect. Below this critical level, discharge breakdown occurs as a slow erosion process involving the removal of cations from the mica structure, probably by a polarity dependent mechanism.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132982422","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Mitsui, T. Kobayashi, H. Shimizu, S. Nagasaki, H. Matsubara, M. Kuno, H. Komatsubara, T. Okada
{"title":"Morphological study of treeing phenomena in PE and XLPE","authors":"T. Mitsui, T. Kobayashi, H. Shimizu, S. Nagasaki, H. Matsubara, M. Kuno, H. Komatsubara, T. Okada","doi":"10.1109/EIC.1984.7465139","DOIUrl":"https://doi.org/10.1109/EIC.1984.7465139","url":null,"abstract":"The authors have been studying to improve the performance of insulation materials in order to promote a significant increase in the reliability and the cost advantages of XLPE cables. Towards that end, a method to observe the supermolecular structures of insulation materials and the treeing phenomena directly and simultaneously has been developed, and is herein discussed. The method was applied to the observation of actual XLPE cable insulation successfully. Generation of micro cavities were found at the amorphous region between the lamellae in the electrical-charged specimens, so it is believed that studies on the lamellae and the amorphous region are important to promote the understanding of the treeing mechanism.","PeriodicalId":181306,"journal":{"name":"1984 IEEE International Conference on Eletrical Insulation","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1984-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116106646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}