2010 15th National Biomedical Engineering Meeting最新文献

筛选
英文 中文
Texture analysis of liver cirrhosis 肝硬化的肌理分析
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479742
Omer Kayaalti, B. H. Aksebzeci, M. H. Asyali, O. Karahan, K. Deniz, M. Ozturk
{"title":"Texture analysis of liver cirrhosis","authors":"Omer Kayaalti, B. H. Aksebzeci, M. H. Asyali, O. Karahan, K. Deniz, M. Ozturk","doi":"10.1109/BIYOMUT.2010.5479742","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479742","url":null,"abstract":"Liver with cirrhosis emerges when the cells of liver begin to die and the tissues become a functional knot from these. In the diagnosis of fibrosis, the needle biopsy is a golden standard. Although this technique is a good techique in reaching accurate diagnosis, its being an invasive method arises disadvantage. The developments in medical image processing and artificial intelligence techniques have advanced the potential of using diagnosis system in classification of liver tissues. In this study, we have aimed at producing some objective measures using image analysis, which will be of assistance in the diagnosis of cirrhosis. In order to differentiate between regions of liver with cirrhosis and healthy parenchymal tissues, we have used first order statistical texture features and second order texture features computed from gray level cooccurrence matrix of liver computerized tomography (CT) images. Then liver CT images of healthy people and people with cirrhosis have been classified with support vector machines (SVM) by using all these acquired features. The most successful classification has been calculated as 85.19% with the method of 10 fold cross-validation.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127416621","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Sinc interpolating approach to sub-pixel image stitching for virtual microscopy 虚拟显微镜亚像素图像拼接的正弦插值方法
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479798
Gökhan Baş, G.K. Demir
{"title":"Sinc interpolating approach to sub-pixel image stitching for virtual microscopy","authors":"Gökhan Baş, G.K. Demir","doi":"10.1109/BIYOMUT.2010.5479798","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479798","url":null,"abstract":"This study involves a two-step approach to the stitching of images taken for virtual microscopy application. The method has a sub-pixel resolution. To achieve this, first, a coarse shift level is adopted via a correlation function, and then a sinc interpolation is applied to the small neighborhood region of this coarse point. At the end, the sub-pixel shift level is determined by obtaining the maximum of the interpolated function using a gradient descent algorithm. Image stitching process is finalized with linear blending. Results are obtained within the range of ten percent subpixel tolerance.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127796858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Epileptic source localizations based on EEG and SDE measurements 基于脑电图和SDE测量的癫痫源定位
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479788
A. Duru, G. Akdeniz, E. Kara, Ç. Özkara, M. Uzan, A. Ademoglu, T. Demiralp
{"title":"Epileptic source localizations based on EEG and SDE measurements","authors":"A. Duru, G. Akdeniz, E. Kara, Ç. Özkara, M. Uzan, A. Ademoglu, T. Demiralp","doi":"10.1109/BIYOMUT.2010.5479788","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479788","url":null,"abstract":"Epilepsy is one of the most common diseases related to the disfunctioning of the central nervous system. For the patients whose drug therapy turns out to be ineffective, it is a common method to identify the locations of sources that trigger the seizure in the brain tissue and resect them through surgical means for treatment. The success of the surgical operation depends on the accurate localization of the foci. Spatial location of the epileptic foci in the brain can be determined by solving the inverse problem using the EEG and SDE measurements. In this study, a source localization validation is performed using the surface and cortex electrical measurements of an epilepsy patient who has underwent a resection operation.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129857366","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Creating head model by using 3-D pattern and evaluation of SAR mapping with numerical methods 利用三维模式建立头部模型,用数值方法评价SAR制图效果
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479752
L. N. Polat, M. Kahriman, S. Çömlekçi
{"title":"Creating head model by using 3-D pattern and evaluation of SAR mapping with numerical methods","authors":"L. N. Polat, M. Kahriman, S. Çömlekçi","doi":"10.1109/BIYOMUT.2010.5479752","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479752","url":null,"abstract":"In this study, it is aimed to evaluate SAR value occurred in human head in 1800 MHz. First, 3-D basic model of human head was designed by using HFSS (ANSOFT). So, some solutions were obtained from created model with putting source of 1800 MHz electric field in different orientations on 3-plane. This basic approach shows a close agreement with realistic ones.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"434 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122823571","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Sensitivity of circular coils to conductivity changes: Analytical and numerical solutions 圆线圈对电导率变化的敏感性:解析解和数值解
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479791
Koray Özkan, N. G. Gencer
{"title":"Sensitivity of circular coils to conductivity changes: Analytical and numerical solutions","authors":"Koray Özkan, N. G. Gencer","doi":"10.1109/BIYOMUT.2010.5479791","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479791","url":null,"abstract":"The method of contactless conductivity imaging is based on the magnetic-induction magnetic-measurement principle. In this study, the sensitivity of the circular coil used for measuring magnetic fields, to conductivity changes is investigated. To do so, the electrical circuit model of the receiver coil and that of the conductive object is developed. The conductive object is modelled as a thin disk (cylinder) coaxially placed inside the circular coil. Another cylindrical object is assumed to be coaxially placed within the conductive object. It is assumed that, the conductive object is placed within a time varying but spatially constant magnetic field. An analytic formulation is developed for the determination of the sensitivity of the circular coil to the variations of the radius and conductivity of the second object (inhomogeneity). The validity of the model is tested with numerical simulations employing the ANSYS magnetic simulation software. The nonlinearity error between the analytic and numerical solutions is calculated as 1.38% of the full scale for β=0.1, and 11.2% of the full scale for β=0.2.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125438686","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Floating power supply with supercapacitors 带有超级电容器的浮动电源
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479870
Koray Gürkan, E. Özer
{"title":"Floating power supply with supercapacitors","authors":"Koray Gürkan, E. Özer","doi":"10.1109/BIYOMUT.2010.5479870","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479870","url":null,"abstract":"Supercapacitors are commonly used as a back-up or an instant high power source in power electronics applications. This paper presents realization of a floating uninterrupted DC voltage source using supercapacitors. An effective active circuit that equalizes cell voltage of the series connected supercapacitors is also developed.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124088577","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
An electrostatic parylene microvalve for lab-on-a-chip applications 用于芯片上实验室应用的静电聚对二甲苯微阀
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479784
E. Yıldırım, A. Koyuncuoğlu, H. Külah
{"title":"An electrostatic parylene microvalve for lab-on-a-chip applications","authors":"E. Yıldırım, A. Koyuncuoğlu, H. Külah","doi":"10.1109/BIYOMUT.2010.5479784","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479784","url":null,"abstract":"This paper presents a novel electrostatically actuated microvalve for lab-on-a-chip applications, fabricated using surface micromachining techniques. Lab-on-a-chip applications generally involve in-plane microflows. Microvalve mentioned here operates by moving a diaphragm, which is in-plane with the flow, perpendicular to the stream with the help of electrostatic forces. Operating principles and the operation of the valve are presented in the paper.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117198682","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mechanical modeling of microtubules based on nonlocal continuum theory 基于非局部连续介质理论的微管力学建模
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479733
O. Civalek, B. Akgöz
{"title":"Mechanical modeling of microtubules based on nonlocal continuum theory","authors":"O. Civalek, B. Akgöz","doi":"10.1109/BIYOMUT.2010.5479733","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479733","url":null,"abstract":"In the present study, a single elastic beam model based on nonlocal elasticity theory is presented for free vibration analysis of microtubules. The small scale effect is taken into consideration using the Eringen's nonlocal elasticity theory in conjunction with the different types of beam model such as Euler-Bernoulli, Timoshenko, Levinson and Reddy. Numerical results are given to show the size effect on vibration of microtubules.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123647398","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A simple set up for the measurement of patient response time in fMRI 在功能磁共振成像中测量病人反应时间的简单装置
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479840
A. Demir, A. U. Keskin, M. Unsal, A. Bayram
{"title":"A simple set up for the measurement of patient response time in fMRI","authors":"A. Demir, A. U. Keskin, M. Unsal, A. Bayram","doi":"10.1109/BIYOMUT.2010.5479840","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479840","url":null,"abstract":"Because blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) pulse sequences have rapidly changing high field gradients, almost all currently available equipment which measure and record the response of a patient to visual or audio stimuli in fMRI employ fiber-optics based systems. In this work we introduce a simple and low cost patient response set up which does not require fiber-optics based sensors and interface. The basis of the method is to transmit an on/off light signal through the RF shielded window of the scanning room. The performance of the proposed measurement set up is tested using fMRI sequences in a 3 Tesla MRI unit.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129750108","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A realization of a P300 based Brain-Computer Interface system 基于P300的脑机接口系统的实现
2010 15th National Biomedical Engineering Meeting Pub Date : 2010-04-21 DOI: 10.1109/BIYOMUT.2010.5479781
Balkar Erdoğan, N. G. Gencer
{"title":"A realization of a P300 based Brain-Computer Interface system","authors":"Balkar Erdoğan, N. G. Gencer","doi":"10.1109/BIYOMUT.2010.5479781","DOIUrl":"https://doi.org/10.1109/BIYOMUT.2010.5479781","url":null,"abstract":"Brain-Computer Interface is an alternative communication system between human and outside world which enables paralyzed and locked-in patients (like Amyotrophic lateral sclerosis - ALS) to communicate with their environment or control some electronic devices like computer using only their brain activity. Over the last two decades, numerous studies have been performed on this title and researchers proposed various applications and methodologies related to BCI research. In this study, a design and implementation of a P300 based BCI is realized. The hardware of the system consists of a 10 channel Electroencephalography (EEG) device which has been developed in our laboratory for BCI research. As the first application of this system, the so called “P300 Speller” of Farwell and Donchin has been chosen. Several statistical signal processing techniques and operational optimizations have been applied to improve the speed-accuracy performance of this spelling application. According to the online experiment results performed to test the practicality of this system, two out of five healthy participants were able to operate the system using only two trial repetitions for the perfect prediction of the target characters (6 seconds). The average and maximum bit rates of the system were measured to be 10.4bits/min and 31.14bits/min respectively. Regarding these results, the developed system has superior performance as compared to most of the P300 based BCI systems in the literature.","PeriodicalId":180275,"journal":{"name":"2010 15th National Biomedical Engineering Meeting","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127693085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信