1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)最新文献

筛选
英文 中文
Surface acoustic wave gas phase sensor using self-assembled monolayer film 采用自组装单层膜的表面声波气相传感器
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.762204
T. Nomura, A. Saitoh, S. Furukawa
{"title":"Surface acoustic wave gas phase sensor using self-assembled monolayer film","authors":"T. Nomura, A. Saitoh, S. Furukawa","doi":"10.1109/ULTSYM.1998.762204","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.762204","url":null,"abstract":"A surface acoustic wave (SAW) sensor for measuring environment is presented. SAW devices respond to changes in the mass on its surface with a shift in frequency, and offer many attractive features for applications as a gas and liquid phase sensor. In the most gas phase sensor, the device surface is coated with a thin selective film. In this paper a SAW delay line coated with self-assembled (SA) film has been used as environment sensor. A dual delay line was fabricated on a single lithium niobate (128/spl deg/ Y cut X propagating LiNbO/sub 3/) substrate and the propagation path was coated with the selective polymer film deposited by SA transfer technique. The polystyrene sulfonic acid sodium was used as a gas sensing material. Due to sorption of molecules, the electrical conductivity of the SA film changes. The effects caused to reduce the velocity of the SAW. Experimental results showed that the SAW velocity change was quite linear in proportion to the concentration of organic gases. Rapid and totally reversible responses were obtained by using a SA monolayer film.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123732347","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Temperature increase estimates for transabdominal obstetrical exposures 经腹产科暴露的体温升高估计
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765183
W. O’Brien
{"title":"Temperature increase estimates for transabdominal obstetrical exposures","authors":"W. O’Brien","doi":"10.1109/ULTSYM.1998.765183","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765183","url":null,"abstract":"The purpose of the contribution is to estimate the temperature increase for transabdominal obstetrical exposures. The monopole-source solution was used to calculate the 3D complex acoustic pressure field for focused circular apertures from which the 3D temperature distribution was calculated using the bio-heat transfer equation in a layered, perfused media. For the 114 cases, the acoustic field was normalized to the transmit acoustic power required for the derated spatial peak, temporal average intensity I/sub SPTA.3/ equal to 720 mW/cm/sup 2/ for the applicable homogeneous tissue model, the maximum value allowed by the FDA 510(k) diagnostic ultrasound equipment approval process. For the I/sub SPTA.3/=720 mW/cm/sup 2/ condition, the axial temperature increase profiles and maximum temperature increases were determined within the anterior abdominal wall and conceptus. Also, from the normalized acoustic field, the soft-tissue thermal index TIS was determined according to the procedures of the output display standard. The results suggest that the TIS is an adequate indicator for monitoring the myometrium's, and possibly the fetus', maximum temperature increase.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"571 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123399905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Micromachined capacitive transducer arrays for medical ultrasound imaging 医用超声成像用微机械电容式换能器阵列
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765318
X. Jin, F. Degertekin, S. Calmes, X.J. Zhang, I. Ladabaum, B. Khuri-Yakub
{"title":"Micromachined capacitive transducer arrays for medical ultrasound imaging","authors":"X. Jin, F. Degertekin, S. Calmes, X.J. Zhang, I. Ladabaum, B. Khuri-Yakub","doi":"10.1109/ULTSYM.1998.765318","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765318","url":null,"abstract":"The fabrication and characterization of micromachined capacitive ultrasonic transducers are discussed with emphasis on the array operation. Several micromachined capacitive transducer arrays have been fabricated using CMOS compatible micromachining technology. Pulse echo experiments show around 100% bandwidth and the potential for phased array imaging. Radiation pattern and cross-coupling measurements are performed on the 1-D and 2-D arrays. Cross-coupling mechanisms due to Lamb and Stoneley type waves are identified by experiments and verified by theoretical calculations. Deep trench etching between array elements and wafer thinning are proposed to reduce the effects of these spurious waves for certain applications. Initial results on array imaging with 64 element 1D micromachined capacitive transducer arrays are also presented.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129440327","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 38
New expressions for Lamb's problem in solids of general anisotropy 一般各向异性固体中Lamb问题的新表达式
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.762180
C. Wang, J. Achenbach
{"title":"New expressions for Lamb's problem in solids of general anisotropy","authors":"C. Wang, J. Achenbach","doi":"10.1109/ULTSYM.1998.762180","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.762180","url":null,"abstract":"A method to construct solutions for elastic waves generated in a half-space of anisotropic solid has been developed, based on representing the wave field by a superposition of time-transient plane waves. New expressions for the 2-D and 3-D solutions to Lamb's problem in both the time-domain and the frequency-domain have been obtained. These expressions have a simple structure which is attractive for numerical applications.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134082788","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Deformable mesh algorithm for strain imaging with complex tissue deformation 复杂组织变形应变成像的可变形网格算法
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765292
Y. Zhu, M. Insana, P. Chaturvedi, T. Hall, L. Cook, J. Gauch, H. Khant
{"title":"Deformable mesh algorithm for strain imaging with complex tissue deformation","authors":"Y. Zhu, M. Insana, P. Chaturvedi, T. Hall, L. Cook, J. Gauch, H. Khant","doi":"10.1109/ULTSYM.1998.765292","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765292","url":null,"abstract":"This article introduces a framework for strain estimation using interpolated landmark displacement methods. Two implementations of this paradigm, namely, the block matching algorithm and the landmark displacement perturbation algorithm, are described. Results for experiments with phantoms and biological tissues are presented.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126989587","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Elasticity imaging of the liver: is a hemangioma hard or soft? 肝弹性影像学:血管瘤是硬的还是软的?
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765287
S. Emelianov, J. Rubin, M. Lubinski, A. R. Skovoroda, M. O’Donnell
{"title":"Elasticity imaging of the liver: is a hemangioma hard or soft?","authors":"S. Emelianov, J. Rubin, M. Lubinski, A. R. Skovoroda, M. O’Donnell","doi":"10.1109/ULTSYM.1998.765287","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765287","url":null,"abstract":"Diagnosing hemangioma-the most common benign vascular malformation in the liver-requires special and expensive imaging studies including nuclear medicine, magnetic resonance or CT scans. Routine ultrasound is suggestive but not diagnostic. In this paper, we test the hypothesis that hemangioma can be diagnosed using ultrasound-based reconstructive elasticity imaging. A hemangioma consists of large, blood-filled, endothelial-lined spaces separated by fibrous septa. Internally, hemangiomata are soft and spongy. Imaging the elasticity of liver using ultrasound may differentiate hemangioma from other tumor types, and therefore, provide a non-invasive means of hemangioma diagnosis.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"102 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134034004","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Tracking progressive renal disease with quantitative ultrasonic imaging 定量超声成像追踪进展性肾脏疾病
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765088
T. Hall, P. Chaturvedi, M. Insana, J. Wood, H. Khant, Y. Zhu, D. Preston, B. Cowley
{"title":"Tracking progressive renal disease with quantitative ultrasonic imaging","authors":"T. Hall, P. Chaturvedi, M. Insana, J. Wood, H. Khant, Y. Zhu, D. Preston, B. Cowley","doi":"10.1109/ULTSYM.1998.765088","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765088","url":null,"abstract":"Using a combination of techniques, we are studying the progression of polycystic kidney disease (PKD) in a rat model as the disease progresses to renal failure. The goal of our work is to use ultrasound to noninvasively detect morphological changes early in the disease process when interventions are most successful and before there is a significant loss in renal function.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116860028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Non-linear tissue elasticity: adaptive elasticity imaging for large deformations 非线性组织弹性:大变形的自适应弹性成像
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765288
S. Emelianov, R. Q. Erkamp, M. Lubinski, A. R. Skovoroda, Matthew O'Donnell
{"title":"Non-linear tissue elasticity: adaptive elasticity imaging for large deformations","authors":"S. Emelianov, R. Q. Erkamp, M. Lubinski, A. R. Skovoroda, Matthew O'Donnell","doi":"10.1109/ULTSYM.1998.765288","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765288","url":null,"abstract":"Ultrasound's dynamic and interactive (i.e., real-time) nature is it's major advantage compared to other imaging modalities. For elasticity imaging, real-time data capture provides an excellent foundation for retrospective data processing, including adaptive speckle tracking, incompressibility processing, and adaptive elasticity imaging. In this paper, we explore adaptive imaging of elasticity to estimate nonlinear tissue elasticity. Remote assessment of nonlinear tissue elasticity (i.e., strain hardening) can both increase contrast in elasticity images and present an independent means of tissue differentiation.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"222 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131752551","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
Dynamic measurement of surface properties with ripplon spectroscopy 用ripplon光谱学动态测量表面性质
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765035
D. Mizuno, K. Hattori, K. Sakai, K. Takagi
{"title":"Dynamic measurement of surface properties with ripplon spectroscopy","authors":"D. Mizuno, K. Hattori, K. Sakai, K. Takagi","doi":"10.1109/ULTSYM.1998.765035","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765035","url":null,"abstract":"Ripplon light scattering technique was applied for the investigation of the mechanical properties of the surface of surfactant solution. The velocity and damping constant of the ripplon were measured for decyl-alcohol solution under periodical modulation of the surface area and the dynamic surface tension was obtained in the frequency range of 10/sup -3/-10/sup -1/ Hz. The relaxation of surface elasticity due to the adsorption and desorption of the surfactant molecules was successfully observed.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114211246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Segmentation of liver tumors in ultrasound images based on scale-space analysis of the continuous wavelet transform 基于尺度空间分析的连续小波变换超声图像肝脏肿瘤分割
1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102) Pub Date : 1998-12-01 DOI: 10.1109/ULTSYM.1998.765279
H. Yoshida, B. Keserci, D. Casalino, A. Coskun, O. Ozturk, A. Savranlar
{"title":"Segmentation of liver tumors in ultrasound images based on scale-space analysis of the continuous wavelet transform","authors":"H. Yoshida, B. Keserci, D. Casalino, A. Coskun, O. Ozturk, A. Savranlar","doi":"10.1109/ULTSYM.1998.765279","DOIUrl":"https://doi.org/10.1109/ULTSYM.1998.765279","url":null,"abstract":"We have developed a simple, yet robust method for segmentation of low-contrast objects embedded in noisy images. Our technique has been applied to segmenting of liver tumors in B-scan ultrasound images with hypoechoic rims. In our method, first a B-scan image is processed by a median filter for removal of speckle noise. Then several one-dimensional profiles are obtained along multiple radial directions which pass through the manually identified center of the region of a tumor. After smoothing by a Gaussian kernel smoother, these profiles are processed by Sombrero's continuous wavelets to yield scalograms over a range of scales. The modulus maxima lines, which represent the degree of regularity at individual points on the profiles, are then utilized for identifying candidate points on the boundary of the tumor. These detected boundary points are fitted by an ellipse and are used as an initial configuration of a wavelet snake. The wavelet snake is then deformed so that the accurate boundary of the tumor is found. A preliminary result for several metastases with various sizes of hypoechoic rims showed that our method could extract boundaries of the tumors which were close to the contours drawn by expert radiologists. Therefore, our new method can segment the regions of focal liver disease in sonograms with accuracy, and it can be useful as a preprocessing step in our scheme for automated classification of focal liver disease in sonography.","PeriodicalId":175797,"journal":{"name":"1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134405598","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书