Journal of Radiography and Radiation Sciences最新文献

筛选
英文 中文
Computed Tomography Dose for Adult Head Scan in Anambra State of Nigeria 尼日利亚阿南布拉州成人头部扫描计算机断层扫描剂量
Journal of Radiography and Radiation Sciences Pub Date : 2016-12-01 DOI: 10.48153/jrrs/2016/pech1267
T. Adejoh, Chukwuziem N. Anene, U.E. Akanegbu, Samuel A. Imo, Hyacinth U. Chiegwu, E. C. Onwujekwe
{"title":"Computed Tomography Dose for Adult Head Scan in Anambra State of Nigeria","authors":"T. Adejoh, Chukwuziem N. Anene, U.E. Akanegbu, Samuel A. Imo, Hyacinth U. Chiegwu, E. C. Onwujekwe","doi":"10.48153/jrrs/2016/pech1267","DOIUrl":"https://doi.org/10.48153/jrrs/2016/pech1267","url":null,"abstract":"Background: Computed tomography is associated with relatively high radiation doses and could cause serious health risks. Globally, it is reported that many physicians do not to have adequate knowledge about CT dose. Furthermore, although dose records are available from developed countries, there is a paucity of literature in Nigeria. Dose outputs in our locality are also scarce in the literature. \u0000Objective: To review adult head CT dose in the four largest centres in Anambra State. \u0000Methodology: A 6-month retrospective retrieval of dose summary from the control console. Digital folders of subjects ≥ 18 years were sampled purposively and sequentially, out of the 2015 population of CT examinations. The CTDIvol and DLP for each case were recorded in a pro forma. The mean dose in each centre as well as the combined mean for all centres were calculated. The results were compared with the recommendations of the European Commission and similar studies from Nigeria. \u0000Results: The digital folders of 200 subjects made up of 104 (52.0 %) males and 96 (48.0%) females with an age range of 18 – 93 years were involved in the study. Cranium (n = 164; 82 %) dominated the CT requests. The mean CTDIvol and DLP in the four centres was 58 mGy and 1112 mGy.cm. The mean CTDIvol (73 mGy) and DLP (1613 mGy-cm) in one of the centres was extreme. When excluded, the mean CTDIvol and DLP for the remaining three centres were 52 mGy and 945 mGy.cm, respectively. \u0000Conclusion: Dose output in Anambra State was comparable to the recommendation of the European Commission but varied significantly from other local studies. The establishment of diagnostic reference levels for CT procedure in the locality is imperative.","PeriodicalId":16919,"journal":{"name":"Journal of Radiography and Radiation Sciences","volume":"13 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82396308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信