{"title":"SIMPLIFIED ANALYTICAL MODEL FOR THE INVESTIGATION OF THE TRANSIENT THERMAL BEHAVIOR OF THE HEATING RADIANT SLAB","authors":"A. Merabtine, A. Kheiri, S. Mokraoui","doi":"10.2478/9788395669699-018","DOIUrl":"https://doi.org/10.2478/9788395669699-018","url":null,"abstract":"Radiant floor heating systems (FHS) are considered as reliable heating systems since they ensure maintaining inside air temperature and reduce its fluctuations more efficiently than conventional heating systems. The presented study investigates the dynamic thermal response of an experimental FHS equipped with an anhydrite radiant slab. A new simplified model based on an analytical correlation is proposed to evaluate the heating radiant slab surface temperature and examine its thermal behavior under dynamic conditions. In order the validate the developed analytical model, an experimental scenario, under transient conditions, was performed in a monitored full-scale test cell. 2D and 3D numerical models were also developed to evaluate the accuracy of the analytical model. The method of Design of Experiments (DoE) was used to both derive meta-models, to analytically estimate the surface temperature, and perform a sensitivity study.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124418622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
B. Sommer, U. Pont, G. Moncayo, M. Schuß, A. Mahdavi
{"title":"A REVIEW OF THE EVA – PROJECT: EVALUATION OF VISONARY ARCHITECTURAL CONCEPTS IN VIEW OF BUILDING PERFORMANCE","authors":"B. Sommer, U. Pont, G. Moncayo, M. Schuß, A. Mahdavi","doi":"10.2478/9788395669699-028","DOIUrl":"https://doi.org/10.2478/9788395669699-028","url":null,"abstract":"This paper reports on the EVA-project, which was collaboratively conducted by the University of Applied Arts (Energy Design) and the TU Wien (Dept. of Building Physics and Building Ecology). This project focused on the assessment of a number of innovative architectural concepts in the field of energy-efficient architecture. Whereas a large number of building projects focuses on adding thermal insulation and rather rely on the performance of mass products like insulation panels, a by far smaller number of projects try to explore other ways of improving building performance, such as adaptive, moveable, or performance-shifting envelope element. Such architectural concepts often experience contra-arguments, such as the high risk of failure due to childhood diseases in the planning, the fear of increased cost and less-than-expected impact, or even invective as architect’s fantasies. However, the track of innovation often has to cross rickety bridges to be accepted by the AEC (architecture-engineering-construction) domain. Toward this end, the EVA project provides two contributions: On the one hand, a structured evaluation database has been developed, in which “innovative architectural concepts” can be stored and queried regarding their key features. On the other hand, one innovative approach has been chosen, constructed and implemented in an existing building’s envelope. The paper illustrates the idea, the principle construction, and the performance impact of this realization, which was pertaining to radiative heating and cooling achieved by adjustable distribution of thermal mass through indoor panels that were linked to outdoor façade elements.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115889519","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"THE QUALITY OF DAYLIGHT IN VARIOUS TYPES OF RESIDENTIAL BUILDINGS","authors":"Kristýna Schulzová, D. Bošová","doi":"10.2478/9788395669699-026","DOIUrl":"https://doi.org/10.2478/9788395669699-026","url":null,"abstract":"The residential building design must place an emphasis on daylight in interiors, in terms of quality as well as quantity. The legislative requirements are more or less unified across the spectrum of residential building types. The article compares the daylighting conditions in three different types of residential development in Prague: a tenement house from the 19th century, a neighbourhood of precast panel buildings from the second half of the 20th century and a contemporary housing complex. The urban situation, such as distances between the buildings and street profiles, majorly influences the daylight and insolation in the apartments. The apartment layout, the proportions of the room and the size and proportion of the windows are also important factors affecting the distribution of daylight in the rooms. The case study is a part of a larger research project, which aims to create a supplementary teaching material for architecture students, who are learning to design the suitable interiors.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"99 7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128007646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"HYGROTHERMAL MONITORING OF A DOUBLE-SKIN VENTILATED COLD FLAT ROOF","authors":"D. Szagri, B. Nagy, Daniel Bakonyi","doi":"10.2478/9788395669699-032","DOIUrl":"https://doi.org/10.2478/9788395669699-032","url":null,"abstract":"In Central-Europe, a large proportion of people live in prefabricated tower blocks (most commonly called as panel buildings) which were built in the past 30-50 years. These buildings are now obsolete in terms of their energy performance and their condition has deteriorated, therefore they need to be refurbished, which action already started in the past couple of years. One of the most common building construction of tower blocks is the double-skin ventilated cold deck flat roof, which consist of the inner reinforced concrete roof panel, some thermal insulation (expanded polystyrene or mineral wool), a ventilated air layer and the reinforced concrete outer shell which holds the bituminous waterproofing membrane. In our research, we investigated these roofs during a refurbishment of a tower-block building with blown-in glass wool thermal insulation in Budapest, Hungary. We examined the real built-in hygrothermal performance of the double-skin flat roof with blown-in thermal insulation, and how thermal insulation capability changes during the year in these structures. The insulation was designed to not fully fill the ventilated air layer, therefore the cold roof continued to function as a ventilated/slightly ventilated roof. During the refurbishment, the external reinforced concrete shell of the roof was drilled by using a core drill in specified locations and then the glass wool was blown-in. During the process, we have set up a hygrothermal monitoring system in the roof. We placed temperature and relative humidity measuring sensors between the layers of the roof construction at four distinct places in the roof, as well as on the internal and external sides. The measurement procedure lasted for a year. The weather data for the calculations and simulations were obtained from a nearby weather station. In our paper, we analyse the monitoring measurement results, as well as demonstrate the building physical aspects of the refurbishment process and show the real hygrothermal performance of the materials built-in the roof construction.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126094090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}