{"title":"OPTIMIZATION OF BIOCOMPOSITE MATERIALS FOR OUTER SHELL OF BUILDINGS","authors":"L. Bosak, J. Kováč","doi":"10.2478/9788395669699-005","DOIUrl":"https://doi.org/10.2478/9788395669699-005","url":null,"abstract":"","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114889696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PERFORMANCE-BASED RETROFIT CONSIDERATIONS FOR PREFABRICATED BUILDINGS: A CASE STUDY OF ZAGREB, CROATIA","authors":"M. Flegar, U. Pont, A. Mahdavi","doi":"10.2478/9788395669699-011","DOIUrl":"https://doi.org/10.2478/9788395669699-011","url":null,"abstract":"","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"286 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114953114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Savytskyi, Olexandr Bardakh, A. Savytskyi, T. Shevchenko, V. Chernets
{"title":"QUANTITATIVE DESIGN METHODS OF CORROSION PROTECTION THE REINFORCED CONCRETE STRUCTURES AT THE STAGES OF THE LIFE CYCLE","authors":"M. Savytskyi, Olexandr Bardakh, A. Savytskyi, T. Shevchenko, V. Chernets","doi":"10.2478/9788395669699-025","DOIUrl":"https://doi.org/10.2478/9788395669699-025","url":null,"abstract":"Concrete and reinforced concrete are the main structural materials in modern construction. The area and volumes of application of these materials continues to expand. In recent years, in the practice of construction, there is a tendency to the use of structures that combine load-bearing and enclosing functions, as well as the functions of technological equipment. At the same time, their working conditions are becoming more complicated and harsh. In addition to the usual force effects (loads), structures are exposed to all kinds of environmental influences (actions) in the form of substances, energy, or a combination thereof.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123929761","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PCMS IN BUILDINGS: COMPATIBILITY WITH CONTAINER MATERIALS AND ANALYSIS OF ENVIRONMENTAL IMPACTS","authors":"K. Struhala, S. Bantová, M. Ostrý","doi":"10.2478/9788395669699-029","DOIUrl":"https://doi.org/10.2478/9788395669699-029","url":null,"abstract":"","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117129876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"EVALUATION OF THE KUNERT’S GLAZING IN SUMMER AND WINTER CLIMATIC CONDITION IN SLOVAKIA","authors":"D. Szabó, I. Chmúrny","doi":"10.2478/9788395669699-031","DOIUrl":"https://doi.org/10.2478/9788395669699-031","url":null,"abstract":"The paper focuses the measurements of heat losses and solar gains of the Kunerts glazing compared to the ordinary insulating double glazing under actual climate condition in Slovakia. Both sample of glazing have the same thermal transmittance Ug = 1.1 Wm-2 K-1. Measurements were carried out in the Twin-Boxes in location Bratislava. The facade in which the measured samples were installed is oriented to the south. There was a long-term measurement in summer and winter conditions. Technical characteristics of the measured glazing samples and measured values of temperatures, surface temperatures, heat losses or gains, and local climatic conditions measured from the meteorological station located on the roof of the laboratory are described.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131069137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Petr Blasinski, A. Rubina, Olga Rubinová, M. Formánek
{"title":"INFLUENCE OF ELECTROSTATIC CHARGE ON AIR-CONDITIONING FILTERS FROM NANOFIBROUS STRUCTURES","authors":"Petr Blasinski, A. Rubina, Olga Rubinová, M. Formánek","doi":"10.2478/9788395669699-003","DOIUrl":"https://doi.org/10.2478/9788395669699-003","url":null,"abstract":"The objective of the study is to find out what potential has electrostatic charge on the filtration efficiency of nanofilters. The using of filters with nanofibrous structure (fiber thickness is less than 1 μm) is associated with problems of high-pressure loss, which is caused by high density of the filter layer. The high degree of filtration is achieved, but the costs for ventilators power input is very high. Nanofilters are effective in filtering with problematic lower aerosol fractions which is occurring in a common predominantly urban environment. For this reason, a steel grid was placed in front of the nanofibrous filter layer and a potential difference was created between the grid and the filter element. This treatment causes the capture of coarse particles on the steel grid, and the nanofilter retains mainly particles smaller than 0.5 μm. The main aim of the study is to find out whether it makes sense to supplement the filtration system with the influence of electrostatic charging. The idea is especially about separating larger dust particles on a steel grid and electrostatically charged the nanofilter to increase its efficiency. From the results of the measurements mentioned in the article it is stated that in all fractions of the test sample taken together is achieved an average improvement of 14%.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115426679","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"THE MODULAR SWIMMING HALL BUILDING DESIGNS BY F.F. GRÜNBERGER – AN INQUIRY INTO THE BUILDING PERFORMANCE OF VIENNA’S DISTRICT BATHS","authors":"Karoline Walal, U. Pont, A. Mahdavi","doi":"10.2478/9788395669699-035","DOIUrl":"https://doi.org/10.2478/9788395669699-035","url":null,"abstract":"In the year 1968, the municipality of Vienna, Austria decided on a concept regarding the construction of socalled district baths (public indoor swimming halls). The design of many of the public swimming pools constructed in that period was done by Friedrich Florian Grünberger, an architect, who was considered to be an expert on to swimming hall facilities. His entire oeuvre encompassed swimming pool facilities in many countries of central Europe. Moreover, the majority of his Viennese buildings still exists and is in usage, and form the backbone of the swimming sport facilities in Vienna. This contribution reports on the finding of a recently finished master thesis that focused on the energy performance of swimming halls, in detail of the modular swimming halls designed by Grünberger. Thereby, the original bath designs and retrofit measures that have been applied in recent years were considered. Given the high complexity of swimming pool halls, the energy saving potential of such facilities requires a holistic assessment that includes (i) the building’s envelope, (ii) the complex HVAC and operational technology required by the usage, and (iii) the indoor thermal comfort requirements by the customers in the swimming halls. One of the bath halls has been looked upon a bit more in detail (Floridsdorfer Bad). Here, the improvements over time could be studied in detail. The contribution reports onto the current energy usage by the building, contracting models for energy saving, as well as typical policies and potential fallacies of public swimming pool hall retrofit.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124599419","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"LIFE-CYCLE AND HYGROTHERMAL BASED OPTIMIZATION OF INSULATION FILLED MASONRY BLOCKS","authors":"B. Nagy, Alberto Quintana Gallardo, Z. Szalay","doi":"10.2478/9788395669699-020","DOIUrl":"https://doi.org/10.2478/9788395669699-020","url":null,"abstract":"Fired clay masonry blocks are one of the most common building elements in Europe to construct thermal envelopes of buildings. However, due to current energy performance requirements, thermal insulation of buildings has become inevitable. Brick producers, therefore, started to develop their products and, as a possible solution, they come up with thermal insulation filled masonry blocks, which meet the energy performance requirements without the need of additional external insulation. However, there is still considerable potential left in the available range of these bricks to improve their hygrothermal performance. In our research, we connected building physical simulations with life-cycle assessment through a gradient-free geometry optimization method (COBYLA) to obtain better masonry blocks. We performed heat and moisture transfer (HAM) simulations while optimizing the internal geometry of the blocks within the given constraints regarding to manufacturability, and minimized heat losses as well as 50-year CO 2 emission as objectives in the process. We tested the optimization process with mineral wool filled blocks and considered Hungarian climate. The main achievement of the research is that we found new internal geometry designs for insulation filled masonry blocks, which have significantly less thermal transmittance and lower global warming potential of the assumed 50 years of service life than lower thermal transmittances than the reference geometry. We have designed thermal insulation filled masonry blocks based on a 26 cm thick and 50 cm wide initial block and achieved 19.5% reduction in the U-value with the presented bounds and constraints. Our study showed that the new, optimized masonry geometry would save 14.8% of the equivalent CO2 emissions during the 50-year average service life of being built into a masonry façade. Applying an optimization method in masonry block design leads to more energy efficient and sustainable structures, even when same amount of raw materials is used without increasing production cost.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134213797","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"INTERDISCIPLINARY DISCUSSIONS ON SUSTAINABLE USE OF WOOD STRUCTURE AND FIRE RISK - SITUATIONS IN JAPAN AND AUSTRIA -","authors":"Atsuko Tani","doi":"10.2478/9788395669699-033","DOIUrl":"https://doi.org/10.2478/9788395669699-033","url":null,"abstract":"","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129465626","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PREVENTION OF OVERHEATING RISK: ASSESSMENT OF A BUILDING PROJECT WITH LIGHTWEIGHT CONSTRUCTION IN AUSTRIA","authors":"S. Eikemeier, R. Wimmer, A. Mahdavi","doi":"10.2478/9788395669699-010","DOIUrl":"https://doi.org/10.2478/9788395669699-010","url":null,"abstract":"This contribution reports on an ongoing research effort within the project Sim4DLG to reduce the energy and resource use in the building sector via design optimisation of life cycle oriented buildings in Austria. To reduce the heating demand and overheating risk in the cold and warm seasons, a simulation-supported optimization strategy was pursued in addition to the concurrently computed mandatory Austrian energy performance certificate. This approach is applied to different building types, which are to be constructed within the project Life Cycle Habitation. Apart from the heating demand of the buildings, the indoor environment in view of the indoor temperatures was specifically examined to avoid overheating risk and to increase the thermal comfort for the occupants. Furthermore, the potential for preventing summertime overheating was explored according to the requirements of the Austrian standards. This includes an evaluation of simplified calculation method results, computed operative temperature during the course of the day as well as a comparison of the outcome with the findings of parametric simulations. The results suggest that properly dimensioned building parameters of residential buildings with lightweight constructions and low U-value building elements can improve the thermal comfort for the occupants and fulfil the requirements of the Austrian standards for indoor environment conditions.","PeriodicalId":165437,"journal":{"name":"Proceedings of the enviBUILD 2019","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133443199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}