2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)最新文献

筛选
英文 中文
Synthesis of unity magnitude shaper: Extension for explicit fractional derivative systems 单位量级形器的综合:显式分数阶导数系统的推广
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473746
Ahmed Abid, Rim Jallouli-Khlif, N. Derbel, P. Melchior
{"title":"Synthesis of unity magnitude shaper: Extension for explicit fractional derivative systems","authors":"Ahmed Abid, Rim Jallouli-Khlif, N. Derbel, P. Melchior","doi":"10.1109/SSD.2016.7473746","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473746","url":null,"abstract":"This paper presents an approach to determine the time locations of a three-impulses sequence input shaper known as Unity Magnitude shaper (UM). The analytic design of UM shaper is already achieved for undamped systems and for low-damped ones. In this work, the analytic design for damped systems of such shaper is first developed for second order systems, then, extended to explicit fractional derivative systems. Graphical approaches are used to counter analytical difficulties.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134040580","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
New PLL architecture based on sample and hold phase detector without neither filter nor Inverse Sine circuit 基于采样和保持相位检测器的新型锁相环结构,既没有滤波器,也没有反正弦电路
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473765
B. Gassara, N. Masmoudi
{"title":"New PLL architecture based on sample and hold phase detector without neither filter nor Inverse Sine circuit","authors":"B. Gassara, N. Masmoudi","doi":"10.1109/SSD.2016.7473765","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473765","url":null,"abstract":"This paper describe a new design approach of PLL architecture based on Sample and Hold Phase Detector (SHPD PLL). This architecture is a simplification and amelioration of the Inverse Sine Phase Detector (ISPD) PLL [1] [4]. The main difference between the two architectures, that we removed the Inverse Sine function in ISPD model, and replace it by an automatic gain control, which gives PLL more adaptation, stability, wide frequency range and fast response ability. Compared to ISPD PLL, the proposed SHPD PLL is 14 times, faster, more stable and 1.7 times frequency range wider than the, ISPD PLL.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"141 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131496839","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Reliability analysis of distribution systems with hybrid renewable energy and demand side management 可再生能源与需求侧混合管理配电系统可靠性分析
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473684
Maad Alowaifeer, M. Almuhaini
{"title":"Reliability analysis of distribution systems with hybrid renewable energy and demand side management","authors":"Maad Alowaifeer, M. Almuhaini","doi":"10.1109/SSD.2016.7473684","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473684","url":null,"abstract":"Reliability is, and will always be, a crucial mater in designing efficient smart distribution systems. Although renewable based DGs can largely improve the figure of reliability, they may also harm it due to their fluctuating nature. One of the key characteristics of smart distribution systems that could resolve this issue is the demand side management (DSM). DSM refers to any activity done by the utility or the customer to influence load behavior. There are many effective aspects of the DSM that, when addressed efficiently, could benefit both utilities and consumers. In this paper, a reliability assessment of a smart distribution local load system will be studied, including the DSM and the integration of wind and solar energies. The impact of the wind and solar energies on the reliability of the local load will be addressed and compared to base-case reliability. Actual wind speed data and solar irradiation are used in modeling wind and solar power outputs to include seasonal variations. Then, the DSM concept will be implemented to assess the increase in load reliability. Two main DSM aspects are studied and simulated which are load shifting and peak clipping aspects. The Monte Carlo Simulation (MCS) will be utilized to evaluate the reliability for residential, commercial, and industrial loads.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130696299","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
An UWB pulse generator using switching CMOS active inductor oscillator 一种采用开关式CMOS有源电感振荡器的超宽带脉冲发生器
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473691
D. B. Issa, A. Kachouri, M. Samet
{"title":"An UWB pulse generator using switching CMOS active inductor oscillator","authors":"D. B. Issa, A. Kachouri, M. Samet","doi":"10.1109/SSD.2016.7473691","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473691","url":null,"abstract":"A novel design of an Ultra Wide Band (UWB) pulse generator is presented. This topology is based on the switching of a CMOS active inductor oscillator. With the agreement of the desired specifications, the design technique of UWB pulse generator is described in this work. The achieved simulated results show the best performances of the proposed UWB pulse generator in terms of power consumption (22.6mW at 1.8V voltage supply), frequency bandwidth (530MHz), power spectral density (PSD) which is limited to -43.1dBm/MHz and the best agreement in Federal Communication Commission (FCC). This UWB pulse generator is implemented in a 0.18 μm CMOS process technology.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133395798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measuring the junction temperature of an IGBT using its threshold voltage as a temperature sensitive electrical parameter (TSEP) 利用IGBT的阈值电压作为温度敏感电参数(TSEP)测量IGBT的结温
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473664
B. Strauss, A. Lindemann
{"title":"Measuring the junction temperature of an IGBT using its threshold voltage as a temperature sensitive electrical parameter (TSEP)","authors":"B. Strauss, A. Lindemann","doi":"10.1109/SSD.2016.7473664","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473664","url":null,"abstract":"To ensure the thermally safe operation of a power electronic module it is appropriate to monitor the junction temperatures Tj of its semiconductor devices. In addition, a condition monitoring of the power electronic module can be implemented by comparing the measured temperature data with model based calculated values. Using long-term monitoring of Tj, it is possible to determine thermal weaknesses along the heat path between chip and heat sink as well as wearout of the electrical construction. However, since it is not possible to determine the junction temperature directly in standard applications, an indirect method for determining Tj can be applied. In this paper, the concept for measuring the junction temperature of an IGBT by using its threshold voltage Vth, also known as VoE(th), is described.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132773653","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
A low cost signal acquisition board design for myopathy's EMG database construction 一种用于肌病肌电图数据库构建的低成本信号采集板设计
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473767
Rim Barioul, S. F. Ghribi, O. Kanoun
{"title":"A low cost signal acquisition board design for myopathy's EMG database construction","authors":"Rim Barioul, S. F. Ghribi, O. Kanoun","doi":"10.1109/SSD.2016.7473767","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473767","url":null,"abstract":"In the aim of inventing a new method of myopathy's EMG signals classification, diagnostic and treatment the first step is the creation of an EMG database. The raw EMG signals are rich in information but they have to be amplified, converted to a digital form and filtered to be useful in the diagnostic of myopathy. So, to create an EMG database a low cost and high performance acquisition board is designed. An instrumentation amplifier AD524, an Arduino board(to have a real time analogical to digital conversion) and a Wavelet based filter processed on Matlab software were used to obtain an exploitable EMG database. The correctness of stored signals is evaluated by comparing them with themselves when they were stored on computer using a digital scope(metrix 0X6062-II). An SNR metric of 74 dB is calculated, this SNR value is not sufficient to decide of the high performance of the acquisition board. Thus a turn back to compare the representation of a square signal obtained either with the designed board and with the digital scope was done. A calculation of some signal's parameters as period and amplitude shows that the new acquisition board reproduce the input signal shown directly on the screen of the digital scope more closely than that reproduced with the scope's generated data file.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131324209","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Transmitter power influence in a wireless-signal-based system used to monitor catalyst states 用于监测催化剂状态的基于无线信号的系统中的发射机功率影响
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473740
Iurii Motroniuk, R. Stober, G. Fischerauer
{"title":"Transmitter power influence in a wireless-signal-based system used to monitor catalyst states","authors":"Iurii Motroniuk, R. Stober, G. Fischerauer","doi":"10.1109/SSD.2016.7473740","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473740","url":null,"abstract":"We have recently proposed a stochastic microwave-based measurement approach for the loading state of the catalysts used in automotive aftertreatment systems. In this approach, the interior of the catalyst housing acts as a wireless channel between two end devices of a communications system. It was shown that, depending on the transmission channel characteristics, the properties of the catalyst such as its state can be inferred from the properties of some random function such as the received time response (a random function of time) or its Fourier transform, the received spectrum (a random function of frequency). This publication presents results on the resolution of the measurement method when the normalized cross-correlation function between the received spectra with respectively unloaded and loaded catalyst is used as random function. In particular, we have investigated the influence of the transmit signal power. Measurements and signal evaluation were performed for diesel particulate filter (DPF) with different soot loads probed with an ultra wideband (UWB) system and subsequent processing of the waveform in the frequency domain.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116439804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A 3–5 GHz fully differential power amplifier for low power medical applications 3-5 GHz全差分功率放大器,用于低功耗医疗应用
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473728
Amel Neifar, G. Bouzid, M. Masmoudi
{"title":"A 3–5 GHz fully differential power amplifier for low power medical applications","authors":"Amel Neifar, G. Bouzid, M. Masmoudi","doi":"10.1109/SSD.2016.7473728","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473728","url":null,"abstract":"This paper presents the design of a CMOS UWB power amplifier operating in the 3-5 GHz frequency range. The proposed circuit is based on a fully differential topology performing in AB-class to achieve a better linearity and using a bandpass filter network with a shunt feedback technique to obtain wideband matching and flat gain. The design was performed using 0.18 μm technology and simulations results showed a flat power gain of 15.5±0.4 dB across 3-5 GHz band frequency, good input and output return losses with S11 and S22 below -13dB both and excellent phase linearity with a group delay of 18.4 ps while consuming only 25.46 mW from 1.8 V dc, supply.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124098380","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Observation of bubbles inside cryogenic liquids using capacitive multi-electrode sensors 用电容式多电极传感器观察低温液体中的气泡
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473739
Christoph Kandlbinder, A. Fischerauer, Tristan Zürl, T. Helling, G. Fischerauer, M. Siegl, J. Gerstmann
{"title":"Observation of bubbles inside cryogenic liquids using capacitive multi-electrode sensors","authors":"Christoph Kandlbinder, A. Fischerauer, Tristan Zürl, T. Helling, G. Fischerauer, M. Siegl, J. Gerstmann","doi":"10.1109/SSD.2016.7473739","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473739","url":null,"abstract":"The investigation of fluid phenomena is of high interest in the management of cryogenic liquid propellants used in space launch vehicles. In order to efficiently design cryogenic propulsion systems or orbital cryogenic propellant storage facilities, experiments concerning fill-levels, bubble formations and boiling have to be conducted in microgravity and on earth. Thus measurement devices are needed that can give insight into the spatial distribution and the behavior of the fluids inside the cryogenic system. One possibility to observe liquids inside a given volume without intruding into the system and thereby disturbing the flow characteristics is to use a capacitive system with electrodes embedded into the walls of the vessel. In this paper experiments with such a system at cryogenic temperatures are presented. To simulate the behavior of rocket fuel in space a cryostat was filled with liquid nitrogen and by way of controlling the pressure inside or locally heating the liquid, bubbles were created. Two capacitive measurement systems have been submerged into the cryogenic liquid to monitor the location and size of bubbles inside the liquid and to observe the state of the liquid/gas interface. One system consisted of a cylindrical polycarbonate ring with four embedded electrodes and a polycarbonate lid at the top carrying one ring-shaped electrode. Many small bubbles thus could be trapped and coalesced in this half closed cylinder (bubble trap) forming a big single gas volume. The other system was a polycarbonate ring with 16 electrodes arranged along its circumference. The task of these systems was to measure the filling level inside the cylindrical bubble trap and to detect and quantify rising bubbles inside the cryostat by measuring the mutual capacitances of selected electrode pairs. To interpret the measurement results, FEM simulation results were used to generate a characteristic curve for the relationship between filling level and measured capacitances. To validate the results, two cameras were mounted inside the cryostat which allowed the simultaneous recording of the filling level and the existence of bubbles and bubble streams. We observed a good agreement between measurement and simulation. Overall the suitability of the system for cryogenic applications has been successfully demonstrated.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128181722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
PSO optimization of mobile robot trajectories in unknown environments 未知环境下移动机器人轨迹的粒子群优化
2016 13th International Multi-Conference on Systems, Signals & Devices (SSD) Pub Date : 2016-03-21 DOI: 10.1109/SSD.2016.7473756
Safa Ziadi, M. Njah, M. Chtourou
{"title":"PSO optimization of mobile robot trajectories in unknown environments","authors":"Safa Ziadi, M. Njah, M. Chtourou","doi":"10.1109/SSD.2016.7473756","DOIUrl":"https://doi.org/10.1109/SSD.2016.7473756","url":null,"abstract":"The Canonical Force Field (CF2) method is an approach of mobile robot path planning. The variations of CF2 parameters P, c, k, Q and ρ0 are however vital to its performance. In this paper, we used the multi-objective particle swarm optimization (PSO) approach to optimize these parameters. The computation of the optimal parameters is restarted in each new position of the robot. PSO is used to minimize the distance between this position and the target and to maximize the safe distance between this position and the obstacles. The effectiveness of the method is demonstrated by computer simulations in the Webots environment. Simulations are carried out in various known and unknown environments. In the known environments, the obstacle position is recognized by the robot at the beginning of navigation and the path planning is global. But in the unknown environments, the robot localization is based on the sensor readings and the path planning is local.","PeriodicalId":149580,"journal":{"name":"2016 13th International Multi-Conference on Systems, Signals & Devices (SSD)","volume":"157 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2016-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123326272","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×