Iranian Journal of Radiation Research最新文献

筛选
英文 中文
A pre-exposure to RF-EMF can enhance the immune responses of mice following Salmonella Typhimurium and Klebsiella pneumoniae infections 预暴露于射频电磁场可增强鼠伤寒沙门氏菌和肺炎克雷伯菌感染后小鼠的免疫反应
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.333
S. Zarei, S. Tajbakhsh, M. Taheri, H. Mozdarani, A. Jafarzadeh, F. Nouri, S. Nematollahi, S. Dobaradaran, S. Mortazavi
{"title":"A pre-exposure to RF-EMF can enhance the immune responses of mice following Salmonella Typhimurium and Klebsiella pneumoniae infections","authors":"S. Zarei, S. Tajbakhsh, M. Taheri, H. Mozdarani, A. Jafarzadeh, F. Nouri, S. Nematollahi, S. Dobaradaran, S. Mortazavi","doi":"10.18869/ACADPUB.IJRR.18.2.333","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.333","url":null,"abstract":"Background: The question of whether low levels of non-ionizing radiations such as the radiofrequency electromagnetic fields (RF-EMF) can induce the same positive immune responses remains unanswered. This study aimed to investigate the effects of non-ionizing RF-EMF on some parameters of the immune system in an animal model following infection with Salmonella Typhimurium and Klebsiella pneumoniae. Materials and Methods: Male BALB/c mice were exposed to RF-EMFs generated by a common GSM mobile phone for 3 days. Animals were infected with K. pneumonia or S. Typhimurium on the 4 day. On the7 day after injection, blood samples were collected by cardiac puncture. The specific antibodies against bacteria were determined by agglutination method and serum levels of the cytokines were measured using the ELISA method. Moreover, the leukocytes count was measured using a cell counter. Results: The levels of specific antibodies against bacteria were higher in non-irradiated mice compared to irradiated mice. There were no significant differences between the irradiated and non-irradiated mice regarding the total blood leukocyte count. The mean serum levels of IFN-γ and IL-17 after infection with K. pneumoniae were significantly higher in the irradiated mice (p<0.001). Conclusions: Low levels of RF-EMF can stimulate the immune responses in the mice pre-exposed to RF-EMF. This study provides further evidence supporting that exposure to certain levels of RF-EMF can stimulate the immune system. These adaptive responses may be applied to cope with the increased susceptibility of the astronauts to infections during a deep space mission.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41256045","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Investigation of irregular radiation field-based proton therapy using conformal dose layer stacking method 适形剂量层叠加法在不规则辐射场质子治疗中的应用研究
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.295
W. Shao, Xiaobin Tang, C. Geng, Diyun Shu, Chunhui Gong, Xudong Zhang, F. Guan
{"title":"Investigation of irregular radiation field-based proton therapy using conformal dose layer stacking method","authors":"W. Shao, Xiaobin Tang, C. Geng, Diyun Shu, Chunhui Gong, Xudong Zhang, F. Guan","doi":"10.18869/ACADPUB.IJRR.18.2.295","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.295","url":null,"abstract":"Background: Dose modulation is a key factor in practical proton therapy. This study investigates the dose modulation methodology of irregular radiation field (IRF)-based proton therapy using forward radiation treatment planning and conformal dose layer stacking (CDLS) methods. Materials and Methods: The geometric configuration of a virtual multi-leaf system was constructed to generate IRFs during Monte Carlo simulations. Two patient geometries— lymphatic metastasis and brain tumors—were configured to investigate the dosimetric feasibility and applications of IRF-based proton therapy in ideal patient anatomies. The investigated tumors were divided into slices perpendicular to proton beam axis. Segments were designed to be conformal to the profiles of these tumor slices. Conformal dose layers were produced by modulating the proton intensities and energies of the predesigned segments. Then, these dose layers were stacked throughout the tumors to obtain sufficient and conformal tumor doses. Results: From the proposed IRF-based proton therapy, tumors with 4-7 cm extents along the depth direction could be treated with fewer than 10 segments. The lymphatic metastasis and brain tumors were sufficiently covered by 95% dose lines, while appropriate distal and proximal dose conformities were achieved. The maximum tumor doses did not exceed 110%. Conclusions: Theoretically, the proposed IRF-based proton therapy using forward planning and CDLS methods is feasible from the viewpoint of dosimetry. This study can serve as a foundation for future investigations of potential proton therapy methods based on fast conformal dose layer stacking using radiation fields with irregular shapes.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43508787","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Radioactivity level of drilled well water across selected cities in Ondo and Ekiti states, Southwestern Nigeria and its radiological implications 尼日利亚西南部翁多州和埃基蒂州选定城市钻探井水的放射性水平及其放射性影响
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.351
A. Ayodele, O. Ife-Adediran, A. M. Arogunjo
{"title":"Radioactivity level of drilled well water across selected cities in Ondo and Ekiti states, Southwestern Nigeria and its radiological implications","authors":"A. Ayodele, O. Ife-Adediran, A. M. Arogunjo","doi":"10.18869/ACADPUB.IJRR.18.2.351","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.351","url":null,"abstract":"Background: The increasing health effects of nuclear radiation occasioned by enhanced human activities in the environment necessitated the need for constant evaluation and assessment of radiological impact on the general populace within a confined developmental area. Hence, Ten (10) drilled well water samples were collected from various cities distributed across Ondo and Ekiti states and analyzed for gamma-emitting radiations. Materials and Methods: The collected water samples were analyzed using n-type co-axial HPGe detector (Canberra Inc, USA), to determine the activity concentrations of the gamma emitting radiations, which was used with dose conversion factors to calculate the age dependent total annual effective dose equivalents to six different age groups and the committed effective dose for the age group >17y. Results: Activity concentrations ranged from 2.25±0.39 to 35.61±6.22 Bq lTh, 7.08±1.71 to 56.68±12.50 Bq lRa, 45.42±2.98 to 467.61±31.69 Bq lK and 1.66±0.46 to 25.55±5.76 Bq lTh, 4.90±1.08 to 54.18±13.34 Bq lRa, 41.50±2.89 to 558.82±31.69 Bq lK, respectively for Ondo and Ekiti States . Furthermore, the mean total annual effective dose equivalent for the age groups was found to be within the range of (2.81 ± 0.46 – 26.91 ± 5.11) mSv/y and (4.71 ± 0.92 – 23.58 ± 5.12) mSv/y respectively for Ondo and Ekiti states. Conclusion: This is above the 1.0 mSv y and 0.1mSv y respectively set by ICRP and WHO. Hence, the drilled wells are recommended for water screening to remove radionuclides.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48945261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Radiation exposure to patients and examiners during endoscopic retrograde cholangiopancreatography procedures 内镜逆行胰胆管造影术中患者和检查者的辐射暴露
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.375
M. Toossi, H. Zare, S. Bayani, M. Hashemi, N. Mohamadian, Z. Eslami, S. Seyedi
{"title":"Radiation exposure to patients and examiners during endoscopic retrograde cholangiopancreatography procedures","authors":"M. Toossi, H. Zare, S. Bayani, M. Hashemi, N. Mohamadian, Z. Eslami, S. Seyedi","doi":"10.18869/ACADPUB.IJRR.18.2.375","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.375","url":null,"abstract":"Background: Endoscopic retrograde cholangiopancreatography (ERCP) is now widely used in the diagnosis and treatment of gastrointestinal tract disorders. A large number of X-ray fluoroscopy and digital radiographs make ERCP as an interventional radiological procedure. In this study, patients' and examiner's entrance skin doses (ESDs) were measured during diagnosis and treatment procedures and patients' effective dose (ED) were calculated. Materials and Methods: Thermoluminescent dosimeters (TLDs) and dose area product meter (DAP) were used to measure ESDs of 30 patients and examiner and calculate patients' ED. Besides, to assess the effectiveness of an extra lead shield in decreasing examiner's ESDs, a lead cover was wrapped around the Xray tube. The data were analyzed with IBM SPSS Statistics version 16 software. Results: The mean DAP and fluoroscopy time (FT) of the diagnostic procedure were 4.09 Gy.cm and 32.4 s while those of the therapeutic procedure were 7.60 Gy.cm and 76.2 s. The strong linear correlation between DAP and FT was observed for the therapeutic procedures but the diagnostic ones. The patients' mean EDs of diagnostic procedure (1.21±0.52 mSv) and therapeutic one (2.25±1.72 mSv) were calculated. Moreover, the shielding cover around the X-ray tube decreased ESDs of the organs of interest except gonads. Conclusions: The results reveal that therapeutic ERCP procedure imposes a greater radiation dose compared to diagnostic ERCP one. However, the doses of the patient and the examiner depend highly on examiner's experience, technical skills and knowledge in radiation protection. The results suggest that attempts to reduce radiation doses should be made.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49502231","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Monte Carlo study of a free flattening filter to increase surface dose on 12 MV photon beam 增加12MV光子束表面剂量的自由平坦滤波器的蒙特卡罗研究
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.307
A. Zeghari, R. Saaidi, R. Moursli
{"title":"Monte Carlo study of a free flattening filter to increase surface dose on 12 MV photon beam","authors":"A. Zeghari, R. Saaidi, R. Moursli","doi":"10.18869/ACADPUB.IJRR.18.2.307","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.307","url":null,"abstract":"Background: Several investigations reported the dosimetric properties of flattening filter free photon beams to enhance the entrance dose in the surface and build up region. This paper was aimed to investigate the effect of the flattening filter free to enhance the dose at the surface and buildup region. Materials and Methods: A 12 MV photon beam of a linear accelerator was modeled and developed in both flattening filter and flattening filter free modes using the Monte Carlo BEAMnrc code. For both modes, the beam dosimetric features, including central axis absorbed doses and photon energy spectra were investigated. Results: A remarkable increase in the dose rate on the surface and build up region were attained with the flattening filter free mode. At the depth of 0 mm on 2×2 cm, 4×4 cm, 5 × 5 cm, and 10×10 cm field sizes, the surface doses between flattening filter mode and flattening filter free mode were augmented from 27.33% to 33.78%, from 28.89% to 35.75%, from 29.44% to 36.39%, and finally from 35.10% to 47.46%, respectively. At the depth of 25 mm for field size from 2×2 cm to 10×10 cm, the buildup doses for flattening filter mode and flattening filter free mode were augmented from 124.89% to 136.72% and from 132.21% to 142.67%, respectively. Conclusion: A significant increase in the entrance and buildup dose rate was observed when using an unflattened photon beam, which can be a benefit for the treatment of some skin cancers.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49639124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Radioecological research of some water resources in central region of Azerbaijan 阿塞拜疆中部地区部分水资源的辐射生态学研究
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.323
A. Garibov, A. Mikayilova, F. Humbatov, M. R. Ghahramani, J. A. Nagiyev
{"title":"Radioecological research of some water resources in central region of Azerbaijan","authors":"A. Garibov, A. Mikayilova, F. Humbatov, M. R. Ghahramani, J. A. Nagiyev","doi":"10.18869/ACADPUB.IJRR.18.2.323","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.323","url":null,"abstract":"Background: In this proposed work, the products of U radioactive decomposition: Ra, which has a comparatively great decomposition period and Ra intermediate product of Th were examined, which were more prevalent in water samples of the territories investigated. Natural radionuclides are usually observed more in artesian well waters than in river and canal waters, and less in comparison with groundwater. Materials and Methods: For studying the concentration of radionuclides in drinking and agricultural water, samples were collected from Kura River, Yukhari Garabakh and Yukhari Shirvan channels and from artesian wells in different regions. For measurement of radioactivity, gamma spectrometer with high-sensitivity Ge-detector was used, controlled by the software Genie 2000 (manufactured by CANBERRA firm). Results: The obtained results for well waters showed high activity concentrations; the total effective doses for all radionuclides were 2.54, 4.27, and 0.66 mSv for infants, children, and adults, respectively. Conclusion: From these results, it can be concluded that the investigated water is not acceptable for life-long human consumption.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46486289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Thermal enhancement effect on chemo-radiation of glioblastoma multiform 热增强对多形性胶质母细胞瘤化疗辐射的影响
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.255
S. Mahdavi, Leila Khalafi, A. Nikoofar, P. Fadavi, F. Kalateh, T. Aryafar, H. Foudazi, B. Mofid, G. Sharifi, S. Shivaliloo, H. Abdollahi
{"title":"Thermal enhancement effect on chemo-radiation of glioblastoma multiform","authors":"S. Mahdavi, Leila Khalafi, A. Nikoofar, P. Fadavi, F. Kalateh, T. Aryafar, H. Foudazi, B. Mofid, G. Sharifi, S. Shivaliloo, H. Abdollahi","doi":"10.18869/ACADPUB.IJRR.18.2.255","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.255","url":null,"abstract":"Background: Hyperthermia plays a significant role in the chemo-radiotherapy effect in different malignancies. In this research, we treated Glioblastoma multiform (GBM) patients with hyperthermia (HT) along with the chemoradiation, in order to evaluate HT efficacy in terms of tumor volume changes, survival time, and probability. Materials and Methods: Thirty-eight GBM patients were distributed into two groups identified as chemoradiation (CRT), and also CRT plus HT (CRHT). The Karnofsky Performance Status Scale (KPS) was done before, immediately and three months after treatments. Capacitive hyperthermia device was used at frequency of 13.56 MHz (Celsius 42+ GmbH, Germany) for HT one hour before the radiotherapy for 10-12 sessions. Patients in both groups underwent MR imaging (1.5 Tesla) before, 3 and 6 months after the treatments. Thermal enhancement factors (TEF) were attained in terms of clinical target volume changes, TEF(CTV), and survival probability (SP) or TEF(SP). Results: Age ranges were from 27-73 years (Mean=50) and 27-65 years (Mean=50) for CRT and CRHT groups, respectively. For 53% and 47% of cases biopsy and partial resection were accomplished in both groups, respectively. Means and standard deviations of tumor volumes were 135.42±92.5 and 58.4±104.1cm before treatment in CRT and CRHT groups, respectively, with no significant difference (P= 0.2). TEF(CTV) value was attained to be as 1.54 and 1.70 for three and six months after treatments, respectively, TEF(SP) was also equal to the 1.90. Conclusion: HT enhanced the chemoradiation effects throughout the patient survival probability and KPS. TEF may reflect the hyperthermia efficacy for a given radiation dose.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43243262","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Measurement of 222-Rn concentration levels in drinking water samples from Qena city (Egypt) and evaluation of the annual effective doses 对Qena市(埃及)饮用水中222个Rn浓度水平的测量和年度有效剂量的评估
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.227
S. Khaled, A. M. Khaled, R. Shaban, A. Baset
{"title":"Measurement of 222-Rn concentration levels in drinking water samples from Qena city (Egypt) and evaluation of the annual effective doses","authors":"S. Khaled, A. M. Khaled, R. Shaban, A. Baset","doi":"10.18869/ACADPUB.IJRR.18.2.227","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.227","url":null,"abstract":"Background: Radon is one of the most important radionuclides, formed from the decay of the element radium and more soluble in water. As drinking water is a vital source of life, control of its quality is critical. Drinking water containing high radon levels presents a serious risk to human health. Thus awareness of radon levels in drinking water is extremely significant to protect against radiation exposure. We measured Rn concentrations in different types of drinking water from Qena city, Egypt. Materials and Methods: 111 water samples were collected from various sources in Qena city (77 samples of household tap water, 14 samples of bottled water and 20 samples from municipal public water supply locations). The Rn concentrations were determined using an AlphaGUARD radon gas analyzer. We calculated annual effective dose due to ingestion and inhalation of Rn present in these waters. Results: Rn concentration ranges were as follow: 22.0±0.7 to 118±3 mBq l, from tap water 14±3 to 237±5 mBq l from bottled water and 6.0±0.5 to 30.0±0.9 mBq l from municipal public supplies. The annual effective dose due to inhalation and ingestion of Rn in all types of drinking water measures less than the recommended reference level of 100 μSv y. Conclusion: Based on the obtained results, Rn concentrations in the studied water samples were less than the permitted concentrations of USEPA and WHO guidelines.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42064226","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Assessment of polarization and ion recombination correction factors and leakage of small megavoltage photon beams 极化和离子复合校正因子与小兆伏光子束泄漏的评估
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.219
M. Mohammadi, A. Haghparast, N. Rostampour, Razieh Zaghian, M. Zarsav
{"title":"Assessment of polarization and ion recombination correction factors and leakage of small megavoltage photon beams","authors":"M. Mohammadi, A. Haghparast, N. Rostampour, Razieh Zaghian, M. Zarsav","doi":"10.18869/ACADPUB.IJRR.18.2.219","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.219","url":null,"abstract":"Background: Small field dosimetric challenges lead to a deviation from the reference dosimetry. The aim of this study is to investigate the changes of polarization (kpol) and ion recombination (ks) correction factors and determination of leakage dose in small fields. Materials and Methods: All values were measured on a RW3 slab phantom, at 100 cm Source-to-Surface Distance, 10 cm depth and 6, 10 and 18 MV photon beams for square fields (0.5 to 10 cm). Three ionization chambers (PTW Pinpoint 31014 and 31015, Semiflex 31010) were hired. After the electrometer readout, the correction factors were computed according to the protocol No. 398 of International Atomic Energy Agency's Technical Report (IAEA TRS-398). Results: The kpol (min) and the kpol (max) value occurred in 0.5×0.5 cm 2 and 10×10 cm field size, respectively. Dosimeters with a larger sensitive volume showed greater kpol values. In all three dosimeters, an increasing trend detected in normalized dosimeter reading after working voltage. The level of leakage in all of the values and radiation conditions was at the level of a few Nano colons. Conclusion: The values of kpol and ks in the small fields were different from the reference field. The saturation voltage of the small field dosimeters was greater than the dosimeter working voltage. The leakage values of the dosimeter-electrometer combination in the present study were negligible for all radiation conditions. The correction factors should be considered due to the differences between small fields and reference dosimetric conditions.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45174381","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Increasing radiosensitivity by the combined inhibition of PARP1 and PI3K in BRCA1-mutated triple negative breast cancer 联合抑制PARP1和PI3K在brca1突变的三阴性乳腺癌中增加放射敏感性
Iranian Journal of Radiation Research Pub Date : 2020-04-10 DOI: 10.18869/ACADPUB.IJRR.18.2.283
J. Zhou, L. Tang, X. Zhang, J. Wang, L. Yang, San-Gang Wu
{"title":"Increasing radiosensitivity by the combined inhibition of PARP1 and PI3K in BRCA1-mutated triple negative breast cancer","authors":"J. Zhou, L. Tang, X. Zhang, J. Wang, L. Yang, San-Gang Wu","doi":"10.18869/ACADPUB.IJRR.18.2.283","DOIUrl":"https://doi.org/10.18869/ACADPUB.IJRR.18.2.283","url":null,"abstract":"Background: To evaluate the radiosensitizing effect of co-targeting of poly (ADP-ribose) polymerase-1 (PARP1) (AZD2461) and phosphoinositide-3-kinase (PI3K) (LY294002) in breast cancer 1, early onset gene (BRCA1)-mutated triple negative breast cancer (TNBC) treated in vitro. Materials and Methods: We established HCC1937-PARP1 cells by transfection. Cell proliferation, cell viability, cell cycle, and cell apoptosis were measured and analyzed. Western blotting and quantitative real-time polymerase chain reaction assays were performed. Results: The cell viability of HCC1937 and HCC1937-PARP1 cells was significantly decreased under 5 Gy of irradiation. Cell apoptosis was remarkably increased by irradiation, whereas overexpression of PARP1 resulted in substantial resistance to the radiation-induced changes. Combined inhibition of PARP1 and PI3K enhanced radiation-induced apoptosis and significantly inhibited cell proliferation compared with single-agent treatment. The PI3K inhibitor induced changes in the cell cycle distribution, but the PARP1 inhibitor did not. The expression levels of LKB1, PHLPP and INPP4B increased after combined inhibition of PARP1 or PI3K compared with irradiation alone. Moreover, combined inhibition of PARP1 and PI3K resulted in increased expression of INPP4B when compared with that induced by single -agent treatment. Conclusion: Combined inhibition of PARP1 and PI3K might be an effective therapeutic strategy to enhance radiosensitivity in BRCA1mutated TNBC.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48246697","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信