International Journal of Medical Physics, Clinical Engineering and Radiation Oncology最新文献

筛选
英文 中文
Evaluation of Patient-Specific Quality Assurance for Carbon Ion Radiotherapy Using Full Energy Scanning Method at QST Hospital QST医院全能量扫描法碳离子放疗患者特异性质量保证评价
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.114017
Asami Inomata, M. Katsumata, Sung Hyun Lee, Yuji Suzuki, T. Nakajima, W. Furuichi, Keishi Yamaoka, Atsushi Yamamoto, H. Mizuno, R. Kohno
{"title":"Evaluation of Patient-Specific Quality Assurance for Carbon Ion Radiotherapy Using Full Energy Scanning Method at QST Hospital","authors":"Asami Inomata, M. Katsumata, Sung Hyun Lee, Yuji Suzuki, T. Nakajima, W. Furuichi, Keishi Yamaoka, Atsushi Yamamoto, H. Mizuno, R. Kohno","doi":"10.4236/ijmpcero.2022.114017","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.114017","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"111 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80690604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Computational and Experimental Approaches for Evaluating Dose under a Block in TBI Geometry 脑损伤几何块下剂量评估的计算与实验方法
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.111007
L. Russell, Jussi K. Sillanpáá
{"title":"Computational and Experimental Approaches for Evaluating Dose under a Block in TBI Geometry","authors":"L. Russell, Jussi K. Sillanpáá","doi":"10.4236/ijmpcero.2022.111007","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.111007","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"10 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77350599","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mass Stopping Power and Range of Protons in Biological Human Body Tissues (Ovary, Lung and Breast) 质子在人体生物组织(卵巢、肺和乳房)中的阻团能力和范围
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.111005
Ahlam S. Almutairi, K. T. Osman
{"title":"Mass Stopping Power and Range of Protons in Biological Human Body Tissues (Ovary, Lung and Breast)","authors":"Ahlam S. Almutairi, K. T. Osman","doi":"10.4236/ijmpcero.2022.111005","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.111005","url":null,"abstract":"In this work, the mass stopping power and range of protons in biological human body tissues (ovary, lung and breast) were calculated at the energy ranging from 0.04 MeV to 200 MeV using the MATLAB Program. The data relating to the densities, average atomic number to mass number Z A and excitation energy for the present tissues were collected from ICRU Report 46. The mass stopping power was calculated by the Bethe formula. Moreover, the simple integration (continuous slowing down approximation) method was employed for calculating protons range at the tissues. The results of the mass stopping power versus energy and the range versus energy were presented gra-phically and the empirical formulae for calculating the mass stopping power and the ranges were obtained. The present results for mass stopping powers and ranges were compared with the results obtained by others. Good agreements were found between them, especially at the energy ranging from 3 to 200 MeV.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"13 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81444911","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Calculation of Mass Stopping Power and Range of Protons as Well as Important Radiation Quantities in Some Biological Human Bodyparts (Water, Muscle, Skeletal and Bone, Cortical) 人体某些生物部位(水、肌肉、骨骼、皮质)中质子的质量阻挡力、范围及重要辐射量的计算
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.112009
Ahlam S. Almutairi, K. T. Osman
{"title":"Calculation of Mass Stopping Power and Range of Protons as Well as Important Radiation Quantities in Some Biological Human Bodyparts (Water, Muscle, Skeletal and Bone, Cortical)","authors":"Ahlam S. Almutairi, K. T. Osman","doi":"10.4236/ijmpcero.2022.112009","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.112009","url":null,"abstract":"In this work, the electronic mass stopping power and the range of protons in some biological human body parts (Water, Muscle, Skeletal and Bone, Cortical) were calculated in the energy range of protons 0.04 to 200 MeV using the theory of Bethe-Bloch formula as giving in the references. All these calculations were done using Matlab program. The data related to the densities, average atomic number to mass number Z A and excitation energies for the present tissues and substances were collected from ICRU Report 44 (1989). The present results for electronic mass stopping powers and ranges were compared with the data of PSTAR and good agreements were found between them, especially at energies between 1 - 200 MeV for stopping power and 4 - 200 MeV for the range. Also in this study, several important quantities in the field of radiation, such as thickness, linear energy transfer (LET), absorbed dose, equivalent dose, and effective dose of the protons in the given biological human body parts were calculated at protons energy 0.04 - 200 MeV.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"72 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83955180","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Computed Tomography Protocol Optimisation for Pediatric Head Trauma: Radiation Dose and Image Quality Assessment 儿童头部创伤的计算机断层扫描方案优化:辐射剂量和图像质量评估
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.113014
Evelyn Anaafi, M. Boadu, A. Rusandu, Mercy Afadzi Tetteh, Kwame Anokye Amoabeng
{"title":"Computed Tomography Protocol Optimisation for Pediatric Head Trauma: Radiation Dose and Image Quality Assessment","authors":"Evelyn Anaafi, M. Boadu, A. Rusandu, Mercy Afadzi Tetteh, Kwame Anokye Amoabeng","doi":"10.4236/ijmpcero.2022.113014","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.113014","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"28 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85344505","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quality Assurance in SPECT/CT for Radionuclide Therapy with Lutetium-177 镥-177放射性核素治疗的SPECT/CT质量保证
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.111006
O. Adu-Poku, E. Addison, B. Kwakye-Awuah, S. Inkoom, F. Hasford, Cletus Ahadzie, J. Adom, I. K. Wilson
{"title":"Quality Assurance in SPECT/CT for Radionuclide Therapy with Lutetium-177","authors":"O. Adu-Poku, E. Addison, B. Kwakye-Awuah, S. Inkoom, F. Hasford, Cletus Ahadzie, J. Adom, I. K. Wilson","doi":"10.4236/ijmpcero.2022.111006","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.111006","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"108 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91064457","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Statistical Index for Evaluating the CTV Coverage Loss of Brain Stereotactic Radiosurgery When the PTV Margin Is Zero 评价脑立体定向放射手术中PTV切缘为零时CTV覆盖损失的统计指标
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.111008
Jenghwa Chang
{"title":"A Statistical Index for Evaluating the CTV Coverage Loss of Brain Stereotactic Radiosurgery When the PTV Margin Is Zero","authors":"Jenghwa Chang","doi":"10.4236/ijmpcero.2022.111008","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.111008","url":null,"abstract":"Purpose: To develop a new statistical index “percent CTV (clinical target volume) coverage probability” (%CCP), defined as the probability that a specific percent (e.g., 95%) of the CTV can be reliably covered by the prescription dose, for evaluating the coverage loss of brain (fractionated) stereotactic radiosurgery (SRS/fSRS) when the PTV (planning target volume) margin is zero. Methods: The random variable Q for CTV percent coverage was derived using a previously developed model for CTV random motion that follows a three-dimensional (3D) independent normal distribution with a zero mean and a standard deviation of S σ (for translation) or δ σ (for rotation). Assuming both CTV and PTV are spherical with the same diameter d CTV , the cumulative distribution function of Q could be obtained analytically using the relation of sphere-sphere intersection. The %CCP was then derived as the reliability function of Q and was used to quantify the coverage loss for selected d CTV . Results: The 95% - 95% clinical goal (95% of the times, at least 95% of the CTV is covered) is not achievable with d CTV < 42 mm. For common CTVs (d CTV < 20 mm) encountered in SRS/fSRS, only 60% - 90% of the CTV could be reliably covered by the prescription dose 95% of the time. For 0.5 mm S σ = and 0.4 δ σ =  , the 95% CCP was the highest when the distance between the CTV and the isocenter 0 I T d ⇔ = and gradually decreased with the increasing I T d ⇔ . Conclusions: The %CCP was successfully derived for evaluating the CTV coverage loss for brain SRS/fSRS. When the PTV margin is zero, the 95% - 95% clinical goal cannot be achieved for most targets (d CTV < 42 mm).","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"23 1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83056345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
HalcyonTM Acuros XB vs AAA: A RapidArc Planning Comparison for Head & Neck Cancers HalcyonTM acros XB与AAA:头颈癌快速规划比较
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.114016
J. Mbewe, Sakhele Shiba
{"title":"Halcyon<sup>TM</sup> Acuros XB vs AAA: A RapidArc Planning Comparison for Head & Neck Cancers","authors":"J. Mbewe, Sakhele Shiba","doi":"10.4236/ijmpcero.2022.114016","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.114016","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"17 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77043507","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dosimetric Effect of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Treatments 钴铬稳定硬体在椎旁放射治疗中的剂量学效应
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.113015
G. Tang, T. Losasso, S. Lim, Y. Yamada, M. Bilsky, D. Lovelock
{"title":"Dosimetric Effect of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Treatments","authors":"G. Tang, T. Losasso, S. Lim, Y. Yamada, M. Bilsky, D. Lovelock","doi":"10.4236/ijmpcero.2022.113015","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.113015","url":null,"abstract":"","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91122088","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Use of High Definition Multileaf Colimator for the Treatment of Trigeminal Neuralgia 应用高清晰度多叶准直仪治疗三叉神经痛
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology Pub Date : 2022-01-01 DOI: 10.4236/ijmpcero.2022.113013
Eduardo Cabello Murillo, Ana Milanés Gaillet, Gustavo Pozo Rodriguez, Ángel Gaitán Simón, P. Hernández, Marta Rodríguez, A. F. Sanchez, R. D. Fuentes
{"title":"Use of High Definition Multileaf Colimator for the Treatment of Trigeminal Neuralgia","authors":"Eduardo Cabello Murillo, Ana Milanés Gaillet, Gustavo Pozo Rodriguez, Ángel Gaitán Simón, P. Hernández, Marta Rodríguez, A. F. Sanchez, R. D. Fuentes","doi":"10.4236/ijmpcero.2022.113013","DOIUrl":"https://doi.org/10.4236/ijmpcero.2022.113013","url":null,"abstract":"In the present work, a treatment technique for trigeminal neuralgia (TN) using LINAC radiosurgery is shown. The technique is based on the optimization of ten static arcs in such a way as to minimize the overlapping of the treatment fields with the brainstem. We will call this technique brainstem-optimized (BO). The results are compared with another technique described in the litera-ture known as a virtual cone (VC). The comparison of dosimetry results that have been carried out essentially shows that the doses in the brainstem V12Gy-brainstem, D0.5cm 3 -brainstem and D0.035 cm 3 -brainstem are lower in the BO versus VC technique, and with the parameters V50% (whole brain) and V12Gy-cerebrum higher in BO versus VC. Our goal is to keep the dose to the brainstem as low as possible and, if possible, at most between 12 Gy and 15 Gy. The BO technique meets our purposes and is considered clinically acceptable at our institution.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"94 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86004651","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书