International Journal of Architectural Engineering Technology最新文献

筛选
英文 中文
Study on the Recommended Placement and Air Distribution of Split Floor-Standing Room Air Conditioners 分体式立式空调推荐布局及气流组织的研究
International Journal of Architectural Engineering Technology Pub Date : 2022-09-14 DOI: 10.15377/2409-9821.2022.09.1
Zhiheng Zhang, Yibu Gao, Song Nie, Y. Tian, Chenxi Li, Ran Gao, Kui Yin, Yu Liu, Bo Liu, Hongbin Li
{"title":"Study on the Recommended Placement and Air Distribution of Split Floor-Standing Room Air Conditioners","authors":"Zhiheng Zhang, Yibu Gao, Song Nie, Y. Tian, Chenxi Li, Ran Gao, Kui Yin, Yu Liu, Bo Liu, Hongbin Li","doi":"10.15377/2409-9821.2022.09.1","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.1","url":null,"abstract":"In recent years, split floor-standing room air conditioners have been widely used in civil and office buildings because of their high cooling capacity and easy installation, and the air draft sensation has attracted more and more attention. In this study, a target air supply evaluation index for regional thermal comfort evaluation in the work area, the air velocity target value, is proposed. A computational fluid dynamics model for common office is established, and a total of 204 working conditions are numerically simulated for each combination of different positions, different rotation angles, and different air supply velocities (1 m/s, 2 m/s and 3 m/s) of air conditioners in the room. The influence of the rotation angle of the air conditioner on the indoor air distribution was studied, and the distribution of the indoor velocity flow field at different positions was analyzed. The air-conditioning rotation angle that makes the velocity target value of the five preset planes in the room smaller under different conditions is summarized as the recommended rotation angle. The numerical simulation results were verified by experimental means and found to be consistent with the measured results. This study can provide theoretical guidance and reference for the placement of indoor air conditioning units for users in real life.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"259 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114014708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Speech Quality and Intelligibility Assessments in University Classrooms 大学课堂语音质量和可理解性评价的比较
International Journal of Architectural Engineering Technology Pub Date : 2021-12-28 DOI: 10.15377/2409-9821.2021.08.5
A. Prodeus, Kateryna Kukharicheva, M. Didkovska
{"title":"Comparison of Speech Quality and Intelligibility Assessments in University Classrooms","authors":"A. Prodeus, Kateryna Kukharicheva, M. Didkovska","doi":"10.15377/2409-9821.2021.08.5","DOIUrl":"https://doi.org/10.15377/2409-9821.2021.08.5","url":null,"abstract":"Estimates of speech quality and intelligibility for three university classrooms of small, medium and large sizes are presented. The quality and intelligibility of speech were assessed by objective methods using binaural room impulse responses, measured at 5-6 points of the premises. The measures of speech quality were log-spectral distortion (LSD), bark spectral distortion (BSD) and perceptual evaluation of speech quality (PESQ), and the objective measure of speech intelligibility was the speech transmission index (STI).\u0000Among the quality measures considered, only BSD is shown to be highly correlated with STI measures for all three classrooms. In this case, correlation coefficient R varies from minus 0.6 for a small room to minus 0.98 for a large room. The close relationship between PESQ and STI is observed only in the case of a large classroom (R = 0.96-0.99), and the LSD measure was found to be uncorrelated with STI for premises of all sizes. The obtained results can serve as a justification for the use of BSD instead of STI, and vice versa, in the acoustic examination of classrooms of different sizes.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122247989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Imperfection Tolerances During the Erection of Steel Plate Girders and Geometrical Nonlinearities 钢板梁安装过程中的缺陷公差及几何非线性
International Journal of Architectural Engineering Technology Pub Date : 2021-10-02 DOI: 10.15377/2409-9821.2021.08.3
E. Maiorana, G. Poh’sié, Maël Donko
{"title":"Imperfection Tolerances During the Erection of Steel Plate Girders and Geometrical Nonlinearities","authors":"E. Maiorana, G. Poh’sié, Maël Donko","doi":"10.15377/2409-9821.2021.08.3","DOIUrl":"https://doi.org/10.15377/2409-9821.2021.08.3","url":null,"abstract":"","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"289 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134295409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
On Self-Motions of Planar Stewart-Gough Platforms 平面Stewart-Gough平台的自运动
International Journal of Architectural Engineering Technology Pub Date : 2021-07-13 DOI: 10.15377/2409-9821.2021.08.2
V. Chiroiu, Ctin Mille Bucharest Romania Ultrasonics, C. Brisan, L. Munteanu, C. Rugina
{"title":"On Self-Motions of Planar Stewart-Gough Platforms","authors":"V. Chiroiu, Ctin Mille Bucharest Romania Ultrasonics, C. Brisan, L. Munteanu, C. Rugina","doi":"10.15377/2409-9821.2021.08.2","DOIUrl":"https://doi.org/10.15377/2409-9821.2021.08.2","url":null,"abstract":"","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128705177","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Role of Thermal Storage in Distributed Air-Conditioning Plants: Energy and Environmental Analysis 蓄热在分布式空调装置中的作用:能源与环境分析
International Journal of Architectural Engineering Technology Pub Date : 2020-12-25 DOI: 10.15377/2409-9821.2020.07.7
P. Bevilacqua, Stefania Perrella, Daniela Cirone, R. Bruno, N. Arcuri
{"title":"The Role of Thermal Storage in Distributed Air-Conditioning Plants: Energy and Environmental Analysis","authors":"P. Bevilacqua, Stefania Perrella, Daniela Cirone, R. Bruno, N. Arcuri","doi":"10.15377/2409-9821.2020.07.7","DOIUrl":"https://doi.org/10.15377/2409-9821.2020.07.7","url":null,"abstract":"","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"109 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133674288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Innovative Energy Technologies for Powering Buildings 为建筑物供电的创新能源技术
International Journal of Architectural Engineering Technology Pub Date : 2020-12-25 DOI: 10.15377/2409-9821.2020.07.8
N. Badea, Bucharest Romania Bgv Energy Consultancy Srl, G. Badea, Andreia Podasca
{"title":"Innovative Energy Technologies for Powering Buildings","authors":"N. Badea, Bucharest Romania Bgv Energy Consultancy Srl, G. Badea, Andreia Podasca","doi":"10.15377/2409-9821.2020.07.8","DOIUrl":"https://doi.org/10.15377/2409-9821.2020.07.8","url":null,"abstract":"","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124442765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Transient Two-dimensional CFD Evaluation of Indoor Thermal Comfort with an Intermittently-operated Radiant Floor Heating System in an Office Building 某办公楼地板辐射采暖系统室内热舒适性的瞬态二维CFD评价
International Journal of Architectural Engineering Technology Pub Date : 2020-12-25 DOI: 10.15377/2409-9821.2020.07.6
Jiying Liu, Xuwei Zhu, Moon Keun Kim, P. Cui, Shengwei Zhu, R. Kosonen
{"title":"A Transient Two-dimensional CFD Evaluation of Indoor Thermal Comfort with an Intermittently-operated Radiant Floor Heating System in an Office Building","authors":"Jiying Liu, Xuwei Zhu, Moon Keun Kim, P. Cui, Shengwei Zhu, R. Kosonen","doi":"10.15377/2409-9821.2020.07.6","DOIUrl":"https://doi.org/10.15377/2409-9821.2020.07.6","url":null,"abstract":"To provide excellent thermal comfort in an energy-efficient manner, the radiant floor cooling and heating system has become an attractive technology. In this work, an intermittently-operated radiant floor heating system combined with a ventilation system for use during the weekdays is proposed via a transient two-dimensional computational fluid dynamics model that takes into account the variation of the indoor heat gain. Additionally, intermittent controls based on the minimum outdoor air temperature and the average water supply and return temperature are proposed. Six specifically-designed outdoor air temperature values ranging from -15C to 15C are taken as examples to evaluate the thermal comfort performance using the operative temperature and local thermal discomfort criteria, including the vertical air temperature, floor temperature, and radiant asymmetry. Meanwhile, the percentages dissatisfied induced by the local discomfort parameters above were analyzed.. Results show that for the case with a minimum outdoor air temperature of -14.2 C, the earlier shut-off of the water supply (e.g., 18:00) cannot contribute to maintaining a comfortable environment at 7:00. To eliminate the effect of the indoor heat gain, a water supply shut-off after 20:00 and the pump starting to recirculate water in the concrete slab at 00:00 are encouraged in the case of an insufficient indoor heat gain during the next daytime. The maximum operative temperature commonly occurred between 4:00-6:00 p.m. A trade-off between the percentages dissatisfied and the operative temperature is finally identified. The control strategy of the shut-off of the water supply for two hours at noon and at least four hours during the nighttime is ultimately obtained to yield the acceptable thermal comfort performance in the intermittent operating mode of a floor heating system while effectively reducing energy consumption.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"92 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122734352","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Influence of Water-Repellent Admixtures on the Water-Resistance of Unstabilized and Stabilized Compressed Earth Blocks 拒水外加剂对非稳定和稳定压缩土块抗水性能的影响
International Journal of Architectural Engineering Technology Pub Date : 2020-12-13 DOI: 10.15377/2409-9821.2020.07.5
J. A. Bogas
{"title":"Influence of Water-Repellent Admixtures on the Water-Resistance of Unstabilized and Stabilized Compressed Earth Blocks","authors":"J. A. Bogas","doi":"10.15377/2409-9821.2020.07.5","DOIUrl":"https://doi.org/10.15377/2409-9821.2020.07.5","url":null,"abstract":"The low durability of water action has been the main issue of earth construction since ancient times. In this way, sustainable solutions are needed to improve the earthen building materials water-resistance performance without significantly changing their appearance and eco-friendly nature. This study aims at characterizing the water-resistance of compressed earth blocks (CEB) produced with or without different types of colorless water-repellent admixtures. To this end, different types of unstabilized and 8% cement-stabilized CEB were protected with two post-surface treatments, namely a silane-siloxane based surface water-repellent (SWR) and a natural linseed oil (LO), as well as one olein based integral water-repellent (IWR). Unprotected reference CEB were also considered for comparison purposes. More sustainable CEB were produced with 20% replacement of earth by recycling waste building materials. The CEB were tested in terms of compressive and flexural strength, capillary water absorption, immersion absorption, water permeability, low-pressure water absorption, and water erosion resistance from drip and spray tests. The influence of the moisture content on the compressive strength was also analysed. The cement-stabilization and water-repellent treatments were able to overcome the non-water-resistant nature of unstabilized CEB. In general, the best performance was attained with SWR, followed by IWR. The LO was less effective in reducing the long-term absorption but was able to protect unstabilized CEB from light rainfall simulated conditions. Under severe water erosion, the surface treatments were less effective, but water penetration was reduced up to near 40%. The mechanical strength, total porosity, water permeability and immersion absorption were not significantly affected by water-repellent products. Moreover, the mechanical strength reduction of stabilized CEB after saturation was about 30%, regardless of the water-repellent treatment. The main contribution of water-repellent admixtures occurred in all properties involving capillary absorption.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132055869","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The Important Role of Diagnostics for the Structural Recovery of Historic Buildings 诊断学在历史建筑结构修复中的重要作用
International Journal of Architectural Engineering Technology Pub Date : 2019-10-14 DOI: 10.15377/2409-9821.2019.06.2
A. Grazzini
{"title":"The Important Role of Diagnostics for the Structural Recovery of Historic Buildings","authors":"A. Grazzini","doi":"10.15377/2409-9821.2019.06.2","DOIUrl":"https://doi.org/10.15377/2409-9821.2019.06.2","url":null,"abstract":"Diagnostic tests represent a fundamental phase of knowledge for historical masonry buildings. The correct design of structural recovery and seismic improvement work must be based on the results of the preliminary tests, for a better knowledge of the vulnerabilities and the mechanical characteristics of ancient masonry structures. The Italian technical codes have given great importance to the level of knowledge reached on the existing buildings, promoting the investment of diagnostics as a fundamental phase of the design work. Two case studies of multidisciplinary diagnostic tests, carried out on monumental buildings, are described for the preliminary evaluation of the quantitative and qualitative characteristics of the masonry structures. In both cases the tests allowed to better understand the vulnerabilities of the masonry section and to design the most appropriate strengthening work. The interpretation of the results coming from tests of different typologies allowed to investigate in depth the hidden peculiarities of the historical masonry structures.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"279 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130925500","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Phenomenology and Space in Architecture: Experience, Sensation and Meaning 建筑中的现象学与空间:体验、感觉与意义
International Journal of Architectural Engineering Technology Pub Date : 2019-05-15 DOI: 10.15377/2409-9821.2019.06.1
N. Kirci, Saeid Soltani
{"title":"Phenomenology and Space in Architecture: Experience, Sensation and Meaning","authors":"N. Kirci, Saeid Soltani","doi":"10.15377/2409-9821.2019.06.1","DOIUrl":"https://doi.org/10.15377/2409-9821.2019.06.1","url":null,"abstract":"Until recently, architecture has been mostly evaluated over its stylistic and visual characteristics. Whereas, the architectural space is primarily vital and therefore, it should not be evaluated independently of its environment and users. Pallasmaa emphasizes on the significance of experience and connection with the environment in architecture. Phenomenology, which aims to create sensory perception, is about creating an abstract experience beyond tangibility. Sensing beyond physical entities in spatial experience deepens meaning. Buildings and cities, essentially provide the necessary view to understand and confront the human existence. It is, therefore, important for architecture to be seen as the subject of phenomenology. This paper explores the relationship between phenomenology and architectural space through experience, sensation, and meaning. It argues that the relationship between human and built environment will be strengthened to the extent that the mentioned features could participate in the space.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"201 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124395194","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书