{"title":"Peculiarities of a Rarely Used Method of Measuring the Speech Transmission Index in Premises","authors":"A. Prodeus, Anton Naida, O. Dvornyk, M. Didkovska","doi":"10.15377/2409-9821.2023.10.3","DOIUrl":"https://doi.org/10.15377/2409-9821.2023.10.3","url":null,"abstract":"Evaluation of speech transmission index (STI) in premises allows for determining the speech intelligibility, and therefore the suitability of premises for speech communication. STI measurements using the speech transmission index for telecommunication systems (STITEL) method are rarely performed in rooms, possibly due to insufficient information on the accuracy of this method. In this paper, computer simulations were used to estimate the STI estimation errors by the STITEL method under conditions of noise and reverberation. The pink noise model and the room impulse response estimate of a real room with a reverberation time T60=0.8 s were used for the research. The duration of the test signals varied between 4, 8, 16, 32, and 64 seconds, and the signal-to-noise ratio varied from minus 28 dB to plus 28 dB. The dependences of the bias, standard deviation, and total error of the STI estimate on the duration of the test signal and the signal-to-noise ratio are obtained. It is shown that the total error of the STI estimation is close to 0.03 when the duration of the test signal is 8 s. Under conditions of noise action, this error decreases with a further increase in the duration of the test signal. Under conditions of joint action of noise and reverberation, such a decrease was not observed, while the total error is within 0.03-0.04.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"113 51","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138958494","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Tracing the Historical Development of Architecture in Cyprus and its Resilience to Seismic Hazards","authors":"Georgios Xekalakis, P. Christou","doi":"10.15377/2409-9821.2023.10.1","DOIUrl":"https://doi.org/10.15377/2409-9821.2023.10.1","url":null,"abstract":"Cyprus is an island nation in the eastern Mediterranean Sea, with a rich and varied history of architecture. Located within a seismically active zone, Cyprus has experienced a number of earthquakes over the centuries, with some of them being particularly destructive. This initiative examines the evolution of architecture in Cyprus from 1489 to present, and how this evolution is related to seismic risk. Specifically, the work will register structural elements by time period, and analyze how these elements contribute to seismic response. Further it will explore the development of architecture in Cyprus, from the Venetians to the Ottoman Empire to the British Colonial period, the Greek-Cypriot period, and the modern era, and the structural elements of each time period. The paper describes how the structural elements of each time period affect seismic risk, and what modifications may be necessary in order to improve seismic risk in Cyprus. This paper will provide useful insight into the evolution of architecture in Cyprus and its effects on seismic risk.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123522482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Fire Safety and Prevention Issues in Design of Tall Buildings","authors":"D. Yılmaz","doi":"10.15377/2409-9821.2022.09.10","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.10","url":null,"abstract":"Fire safety design of tall buildings is crucial. The number of floors, the function, and the occupants' features build the complexity in the life and fire safety design of tall buildings. Because of the complexity of each tall building design, specific preventive measures are necessary more than the basic requirements given in the national and local codes. The fire safety design of the world-renowned tall buildings, including Guangzhou International Finance Centre (IFC), Capital Market Authority (CMA) Tower, and Jin Mao Tower are case studies and further focus is made on the facade design of tall buildings. The paper reviews the safety design issues and focuses on the fire evacuation models, estimations, and the effect of different parameters in the success of fire safety design of tall buildings. In addition to the various fire evacuation suggestions, the effect of human behavior in fire is also discussed through the literature review. Fire safety is not only an engineering problem to deal with, but also architects must know the holistic approach in the fire safety design of tall buildings since it involves their architectural design as well. The paper aimed to bring the most arguable issues in the fire safety design of tall buildings together and to highlight the value of different perspectives in achieving a promising fire safety design.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122304832","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reflection of the Freedom Movements on the Relationship between Political Power and Architecture in Paris: Architectural Competitions","authors":"","doi":"10.15377/2409-9821.2022.09.9","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.9","url":null,"abstract":"As its most prominent financier and employer, architecture is closely related to religious, political, and economic power. According to Lefebvre, representation spaces are established to permanently represent politics and ideology and their transmission to new generations. The democratic attitude of the political power will only change the perception known with the representation spaces. Therefore, this study deals with the example of Paris, which was indicated as the capital of the freedom movements initiated in the 1960s, to demonstrate how the relationship between political power and ideology with architecture transformed under the influence of democracy and freedom movements. For this purpose, political ideology between 1960-90 formed in the De Gaulle period and reached the highest level in the Mitterrand time, attracting the entire world's attention, and its relationship with architecture is investigated.\u0000Democratic, pluralistic, participatory, and transparent approaches in politics brought architectural competitions to the agenda by seeking transparency, pluralism, and participation in the production method of architecture above all. These architectural competitions were organized for Paris to reflect the ideological perspective. The crucial result of the libertarian perspectives concerning the city is the importance of publicity as a factor containing the shared spaces of people. The important results concerning the field of architecture are the support of the formation of new ideas, the production of buildings that are the leading symbols of new movements, and providing equality of opportunity for architects.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124696794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Acoustical Evaluation of the Itacuruçá Baptist Evangelical Church","authors":"J. Torres","doi":"10.15377/2409-9821.2022.09.8","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.8","url":null,"abstract":"This paper presents the acoustical evaluation of a representative evangelical church in Rio de Janeiro, Brazil. The analysis, performed through measurements and simulations, has shown that the acoustic field needs to be more appropriate for the temple’s actual use. The analysis measured the impulse responses at 14 positions from 2 source locations and calculated Reverberation Time and Clarity Factor acoustic parameters. According to the literature and the ISO standards, the Reverberation Time was considered higher than the optimum value for both speech or music. An acoustic model for the temple was developed using the BRASS simulator. The simulation results were compared to measured data to validate the acoustic model. Based on that and aiming to achieve optimum acoustic parameters, a new model was proposed to evaluate alternatives to adequate the acoustical characteristics of the temple. The strategy to develop the final model and to achieve the target Reverberation Time is presented and discussed. An acoustic intervention is then proposed and evaluated using simulated data. The results obtained with the proposed changes, which considered the inclusion of perforated panels and carpet in some walls, were adequate, providing Reverberation Time in accordance to the standards and significant improvement to Clarity for music and speech.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127185222","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"FEM for the Acoustic Modeling of Eigenmodes: Case of the Cultural Heritage Monument of Neoria, Crete","authors":"N. Papadakis, G. Stavroulakis","doi":"10.15377/2409-9821.2022.09.7","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.7","url":null,"abstract":"Eigenfrequencies inside a space significantly affect its acoustic characteristics, especially below the Schroeder frequency in the low-frequency range. In Architectural Acoustics, accurate detection and visualization of eigenmodes can be particularly useful in practical applications. One of the most important landmarks in Chania, Greece, is Neoria, a cluster of 16th-century Venetian shipyards. One existing Neoria will be converted and used as a multipurpose hall. For this objective, acoustic modeling and various measurements were performed in the space. One of the purposes of the measures and modeling was the investigation of the eigenfrequencies and the eigenmodes of the area. Finite Element Method (FEM) was used for the acoustic modeling, while the acoustic measurements were performed in various positions according to ISO 3382-1. Impulse responses were measured, and frequency responses of the space were extracted using Fourier analysis. The measurements and the acoustic modeling results show that the frequencies with the most significant effect on the area are 86.1 Hz, 150.7 Hz, and 204.6 Hz. Eigenmodes of the frequencies are visualized with the application of FEM and especially the positions of nodes and antinodes, which can be utilized appropriately for the optimum placement of absorbers and diffusers in the space.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126110696","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Optimal Reverberation for Masjids","authors":"A. Elkhateeb, S. Eldakdoky","doi":"10.15377/2409-9821.2022.09.6","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.6","url":null,"abstract":"This study investigates the optimal reverberation time in masjids (mosques) from worshippers' viewpoint for the two modes of performance: recitation and sermon/speech. It also examines the effect of both age and gender on worshippers' preferences. To this end, specially convolved five audio clips (five acoustic setups) for each mode were created and uploaded to Google Drive. More than 300, Arabic-speaking participants, males, and females of different ages, listened to these clips. The participants judged the quality (Q, or appropriateness) of these audio clips for listening either to the recitation (QR) or speech (QS) on a unipolar discrete five-grade scale via a questionnaire that was created on Google Forms. Results indicated that both QR and QS are functions of gender and age. Overall, younger worshippers preferred higher reverberation and vice versa, while gender significantly affected the perception of the desirable reverberation for both recitation and speech. Females tended to the shorter reverberant environment (1.38 s for recitation mode, 0.75 s for speech mode, in the mid-frequency range) than males who preferred longer reverberation for recitation in particular (1.77 s).","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115405972","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transforming Building Renovation: A Holistic, Strategic Approach with Construction Robot Management","authors":"Badr Ghammad, R. Hu, T. Bock","doi":"10.15377/2409-9821.2022.09.5","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.5","url":null,"abstract":"The purpose of this research is to investigate the topic of the efficient renovation of existing buildings through construction robotics management. The main questions addressed are: How can we increase labor working conditions around construction sites? Why has the productivity of the construction industry decreased? What construction tasks require automation most? What is needed to smoothly integrate single-task construction robots (STCRs) into the established workflows? How can we optimize processes? What management system is required for STCRs? To answer these questions, thorough research has been conducted, including all identifiable resources for the area or problem. In addition, the research has been strengthened by an expert survey to define the focus areas. Further, the analysis of current established solutions and processes resulted in the presentation of a centralized platform for managing STCRs, which has been developed as part of this research. In conclusion, the strategic implications of deploying STCRs through Visual User Experience (VUX), the low-code cloud-based platform, are discussed and reinforced with a business plan to bring the product idea to life.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122061952","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Comparative Study on Performance of Beam and Arch Bridge Subjected to Uniformly Distributed Load","authors":"Shifana Fatima Kaafil Rehumaan","doi":"10.15377/2409-9821.2022.09.3","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.3","url":null,"abstract":"In this paper, an attempt has been made to study the behavior of beam and arch bridges subjected to static uniformly distributed loads. The target audience of this research paper is Architecture students because they would like to visualize the structural concepts for better understanding with minimal calculation. For this reason, a static load test was conducted on three types of beam bridges and on three types of arch bridges. The performance of the arch bridge is studied by changing the type of beam, and the results are compared with the beam bridge. Based on the test results, it is found that the performance of glued beam bridges is recommended for less span than arch bridges.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128840548","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Interference Effects on the Square and Circular Cross-Sectional High-Rise Buildings Under Turbulent Flows","authors":"Cheng-Wei Chen, Yi-Chao Li, Y. Lo","doi":"10.15377/2409-9821.2022.09.2","DOIUrl":"https://doi.org/10.15377/2409-9821.2022.09.2","url":null,"abstract":"Estimating the wind-induced responses of high-rise buildings requires a detailed investigation of wind force characteristics and structural dynamics, especially when an existing neighboring building has an equivalent volume at adjacent locations. The interference effects caused by such an adjacent building may seriously alternate the wind loading characteristics on the target building and further affect its responses to safety or habitability evaluation. This research investigates the interference effects on the wind-induced responses of high-rise buildings under turbulent boundary layer flows based on a series of wind tunnel tests. This study mainly concerns three disturbance factors to the interference effects: the approaching turbulent flows, the interference locations, and two typical section shapes of the concerned high-rise buildings. Results show that the terrain effect, the interference location effect, and the shape effect of both the principal and the interfering buildings significantly change the interference mechanism to the aerodynamic force and the estimated responses. The aerodynamic and the response interference factors defined in this study have shown distinct different patterns, indicating the interfered resonant response plays a vital role in dominating the interference mechanism. Finally, discretized maps with a satisfactory 0.5B × 0.5B grid resolution under statistical assumptions are proposed as examples for future codification works.","PeriodicalId":136126,"journal":{"name":"International Journal of Architectural Engineering Technology","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132006341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}