{"title":"Glass-blown Pyrex resonator with compensating Ti coating for reduction of TCF","authors":"J. Giner, L. Valdevit, A. Shkel","doi":"10.1109/ISISS.2014.6782511","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782511","url":null,"abstract":"This paper demonstrates that the Thermal Coefficient of resonant Frequency (TCF) of a micro glass-blown Pyrex spherical resonator can be substantially reduced by the application of a titanium (Ti) coating. Finite Elements Analysis (FEA) is used to demonstrate that the temperature dependence of the Young's modulus of the shell material is the dominant parameter affecting the TCF of the resonator, clearly suggesting the use of a metallic compensating layer. Experimental characterization demonstrates that the TCF of a Pyrex glass-blown resonator is reduced by 70% (from 73 ppm/°C to 24 ppm/°C) by the application of a 1.33 μm thick layer of Ti. It is predicted by FEM that for a Ti layer thickness on the order of 2.5 μm the TCF will fall below 10 ppm an acceptable value for high performance resonators. This investigation is a step forward in the quest to employ the desirable properties of micro-blown resonators, such as high symmetry, manufacturing tolerances and environmental robustness.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128752133","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of annealing on mechanical quality factor of fused quartz hemispherical resonator","authors":"M. Ahamed, D. Senkal, A. Shkel","doi":"10.1109/ISISS.2014.6782512","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782512","url":null,"abstract":"This paper reports the experimental demonstration of Quality factor (Q-factor) improvement of fused quartz hemispherical resonators after post-fabrication annealing. Several identical fused quartz 3D hemispherical resonators, thickness 1 mm and diameter 10 mm were fabricated using micro-glassblowing process and tested before and after annealing. Results showed that annealing at 800 °C for 6 hours followed by slow overnight cooling significantly improved Q-factor, from 666×103 to 932×103 in our experiments. The annealing dependence was investigated by varying temperature from 500 °C to 800 °C. Change in Q-factor was observed to be minimal (<;10%), when annealed at 500 °C, for both n=2 and n=3 wineglass modes. Q-factor changes were ~40% when annealed at 800 °C. The experimental result on Q-factor enhancement is valuable for the development of very high Q fused quartz vibratory MEMS resonators for use in precision inertial sensing.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132004855","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wafer level hermetic encapsulation of MEMS inertial sensors using SOI cap wafers with vertical feedthroughs","authors":"M. M. Torunbalci, S. E. Alper, T. Akin","doi":"10.1109/ISISS.2014.6782539","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782539","url":null,"abstract":"This paper reports a new, inherently simple, and high-yield wafer-level hermetic encapsulation method developed for MEMS inertial sensors, enabling lead transfer using vertical feedthroughs that do not require any complex via-refill or trench-refill processes. The process requires only seven masks to complete both the sensor and cap wafers, whereas the combined yield for the sealing and lead transfer is experimentally verified to be above 90%. Hermetic encapsulation is achieved by Au-Si eutectic bonding, and the pressure inside the encapsulated cavity has been characterized to be as low as 1 mTorr with a thin film getter. MEMS resonators packaged with the proposed method demonstrated quality factors over 125,000. The pressure inside the encapsulated cavities has been monitored for 4 months since the first prototypes, and it is observed to be stable throughout this period.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130727998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"IMU calibration on a low grade turntable: Embedded estimation of the instrument displacement from the axis of rotation","authors":"Alexander Kozlov, I. Sazonov, N. Vavilova","doi":"10.1109/ISISS.2014.6782525","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782525","url":null,"abstract":"The paper concerns one simple method of calibration of an assembled inertial measurement units (IMU) of different grades on a low grade single axis turntable. The main feature of the method is that it has the weakest possible requirements to the testbench. The method was presented at ICINS 2010, ICINS 2013, and is now being used in industry for 3-4 years. It appears to work well in practice. One of special points of this method is the situation, when the IMU is displaced from the axis of rotation. In some cases this fact can be neglected, but in some cases not. It was shown earlier that parameters of this displacement need not to be measured prior to the experiment, but can be estimated automatically during the data processing, similar to the rest of IMU parameters. So the device can be placed arbitrarily onto the stand, and no care of displacement should be taken while conducting the experiment. This work concentrates primarily on aspects of observability and estimation accuracy of IMU displacement (which influence the accuracy of the calibration itself), and shows more variety of experimental results than in previous publications.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127897061","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Trusov, G. Atikyan, D. Rozelle, A. D. Meyer, S. Zotov, B. Simon, A. Shkel
{"title":"Force rebalance, whole angle, and self-calibration mechanization of silicon MEMS quad mass gyro","authors":"A. Trusov, G. Atikyan, D. Rozelle, A. D. Meyer, S. Zotov, B. Simon, A. Shkel","doi":"10.1109/ISISS.2014.6782537","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782537","url":null,"abstract":"This paper reports experimental demonstration and characterization of the MEMS Quadruple Mass Gyroscope (QMG) operated in three distinct mechanizations, namely force rebalance, whole angle, and virtual carouseling self-calibration. The three runtime interchangeable control modes are implemented using a custom standalone electronics suite running control firmware with a separate computer GVI for experiment control and data logging. The results of this work demonstrate that the Coriolis Vibratory Gyroscope (CVG) Class II theoretical framework developed by D.D. Lynch is directly applicable to MEMS devices and establishes a path for potentially groundbreaking improvement of their long term stability in support of inertial navigation through self-calibration. While the simple fabrication and outstanding measured characteristics of the QMG (Q>106, Δf<;0.2 Hz, τ>170 s, Δ(1/τ)<;10-4Hz) make it an ideal MEMS Class II CVG, a wide variety of other planar and 3-D mode-symmetric MEMS gyroscope resonators can leverage the developed approach, hardware, software, and analysis tools.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129954733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Lévy, D. Janiaud, J. Guerard, R. Taibi, O. Le Traon
{"title":"A 50 nano-g resolution quartz Vibrating Beam Accelerometer","authors":"R. Lévy, D. Janiaud, J. Guerard, R. Taibi, O. Le Traon","doi":"10.1109/ISISS.2014.6782532","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782532","url":null,"abstract":"This paper reports the design, realization and test of a 50 nano-g resolution Vibrating Beam Accelerometer (VBA). Based on the VIA or DIVA quartz vibrating beam accelerometers, dedicated for tactical applications (±100 g measurement range, 300 μg repeatability, all errors combined), this work explores the improvement of the VBA resolution by reducing the measurement range to ±10 g, targeting navigation applications for lower dynamic vehicles.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128822777","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R. Kuells, Matthias Bruder, S. Nau, M. Salk, K. Thoma, W. Hansch
{"title":"Design of a 1D and 3D monolithically integrated piezoresistive MEMS high-g accelerometer","authors":"R. Kuells, Matthias Bruder, S. Nau, M. Salk, K. Thoma, W. Hansch","doi":"10.1109/ISISS.2014.6782509","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782509","url":null,"abstract":"This paper reports on the design of a new monolithically integrated 3-axis high-g accelerometer. It is based on a 1D-sensor which exhibits a sensitivity of 0.65 μV/V/g and a resonant frequency of 1.5 MHz. Both figures are higher than for any piezoresistive high-g accelerometer in the literature or on the market and are due to an unconventional spring-mass-system geometry. The 3-axis accelerometer incorporates the 1D- design to form a single-crystal silicon 3D-sensor.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122848187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Hamilton, Matt Jaffe, Justin M. Brown, B. Estey, H. Mȕller, R. Compton, K. Nelson
{"title":"Concept of a miniature atomic sensor","authors":"P. Hamilton, Matt Jaffe, Justin M. Brown, B. Estey, H. Mȕller, R. Compton, K. Nelson","doi":"10.1109/ISISS.2014.6782507","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782507","url":null,"abstract":"We present preliminary results of our research program towards multi-axis quantum acceleration sensors in a compact package, using Bloch oscillations of matter waves to provide large momentum transfer. The projected performance is discussed. We demonstrate the first Mach-Zehnder atom interferometer in which a cavity mode is used for addressing the atoms.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134137565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Adaptive mismatch compensation for vibratory gyroscopes","authors":"Fu Zhang, E. Keikha, B. Shahsavari, R. Horowitz","doi":"10.1109/ISISS.2014.6782514","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782514","url":null,"abstract":"This paper presents an online adaptive controller to compensate damping and stiffness frequency mismatches in vibratory gyroscopes. This adaptive controller is running together with the method of averaging. The adaptive controller first estimates the effective damping and stiffness frequency mismatches using least square method and then compensates these estimated mismatches in an online fashion. Simulation results show that the proposed adaptive mismatch compensation controller can eliminate the effects of damping and stiffness frequency mismatches on quadrature oscillation, precession angle oscillation and precession angle drift very effectively.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122044866","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Aleksandrov, Maribel Reyes Romero, E. Soto, R. Vega, T. Alexandrova, D. I. Bugrov, A. Lebedev, S. Lemak, K. V. Tikhonova
{"title":"Mathematical modeling of output signal for the correction of the vestibular system inertial biosensors","authors":"V. Aleksandrov, Maribel Reyes Romero, E. Soto, R. Vega, T. Alexandrova, D. I. Bugrov, A. Lebedev, S. Lemak, K. V. Tikhonova","doi":"10.1109/ISISS.2014.6782526","DOIUrl":"https://doi.org/10.1109/ISISS.2014.6782526","url":null,"abstract":"A mathematical model of the primary afferent neuron activity of the vestibular apparatus, which is the output signal of the vestibular inertial biosensor is presented. The model is based on experimental data from recordings in isolated vestibular neurons. Deterministic and stochastic analysis of our model has been done. Using this model, it might be possible, using galvanic stimulation of low amplitude applied to periauricular region, to correct the output from the vestibular apparatus. This galvanic stimulation should take place against a background of Gaussian white noise with optimal intensity. Computer analysis has shown that the formation of stochastic resonance makes galvanic stimulation more effective. Our model can process the corrective signal of the vestibular output in various conditions. An algorithm for the correction using galvanic stimulation is presented.","PeriodicalId":131121,"journal":{"name":"2014 International Symposium on Inertial Sensors and Systems (ISISS)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125987360","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}